xantrex
Smart choice for power™
XANTREX™ GT SERVICE
COMMITMENT
XANTREX GT SERVICE COMMITMENT
► 10 year parts and labor warranty
► Dedicated toll free installer support line 1.866.492.6873. Open from 5:30 AM to 5 PM Pacific Time
► Streamlined GT service process:
► No Xantrex technical support troubleshooting required for inverter service exchange authorization
► Inverter exchange replacements ship within 48 hours (2 business days) at no cost
► Free overnight shipping of replacement inverters is available upon installer request
► UPS call tag provided to installer for free shipping back to Xantrex
► $250 installer reimbursement check issued within four weeks of receipt of returned inverter
For more info please visit www.xantrex.com/GTSeries
©2008 Xantrex and Smart choice for power are trademarks or registered trademarks of Xantrex International.
2_homepower-gt-commit
Alternative Energy Meets Affordability
SunMaxx Solar Hot Water
Systems provide the greatest
value on the market - offering
top-level performance at a
price hundreds of dollars
lower than the leading com-
petitors.
Today, heating costs for hot
water and our homes can
account for more than 40% of
our home’s energy bills - with
the price of oil and other fossil
fuels rising every day, with no
end in sight, it is important
that we begin to look for alter-
native ways to provide the
necessities of life, such as hot
water and a warm welcoming
home.
SunMaxx Solar Hot Water
Systems can offset 60 - 80%
of your home and water heat-
ing needs - and many of our
systems have a payback
under 5 years.
Free hot water and home
heating can be yours in just
days - call SunMaxx today
and take the first step toward
affordable energy indepen-
dence.
Since day one, SunMaxx has
strived to make alternative
energy affordable for hom-
eowners across the country,
and SunMaxx Solar Hot
Water Systems make this
mission a reality today!
Pay Less for More with
SunMaxx!
June/July Bonus:
SunMaxx
Solar Hot Water Systems
Evacuated Tube
Solar Collectors
S’
Flat Plate
Solar Collectors
Therm osyphon
SHW Systems
Pre-Packaged
Domestic HW
Solar Pool/Spa
Heating Kits
SunMaxx-20
Evacuated Tube Solan Collectors
Only $749.95
(msrp: $850.00)
FEATURED PRODUCTS
MSRP
SunMaxx-25
$999.00
SunMaxx-30
$ 1,399.00
SunMaxx-TS20
$ 1,195.00
SunMaxx-TS30
$ 1,395.95
40 Gallon Storage Tank
$ 900.00
80 Gallon Storage Tank
$ 1,800.00
* Prices Subject to Change
Certified • Outperforms Leading Compe^jjtors J
Solar Hot Water
Chiller/ AC Kits
Solar Hot Water
Stroage Tanks
Plate & Tube
Heat Exchangers
Circulator Pumps
Controllers & More
V.
Shops 100’s of Solar Products
Online @
www.siliconsolar.com
Dealers Si Installers Wanted: inquire Tod
Ul> Silicon Solar Inc
Innovative Solar Solutions™
Products Services Learning Center
PARTNER WITH A GLOBAL LEADER!
There has never been a better time to invest in a solar energy system. Conergy makes it possible with
an array of premium products supplied by the world’s leading manufacturers, custom solar finance
solutions for homeowners and businesses and our national network of elite service providers. In more
than 20 countries on 5 continents, we bring renewable energy solutions tailored to any application
- from large power plants to remote, off-grid homes. Our local expertise, powered by our global
strength makes us your ideal renewable energy partner.
www.conergy.us | (888) 396-6611
OUR WORLD IS FULL OF ENERGY
PHOTO VO LTAICS I SOLAR THERMAL I SOLAR WATER PUMPS I SMALL WIND POWER I BALANCE OF SYSTEM
the heart of your solar system
Deep Cycle Power for Renewable
Energy Systems - Solar , PV and Wind
Off Grid & Grid Tied Systems
Sun Xtender® Batteries are the Original “AGM”
nt Glass Mat) Battery-Designed for the U.S. Military.
— : "'Deep cycle unique high density plat*
superior reliability, power & <. tended cycle iih.
Valve regulated (VR), sealed non^spJHdBle design never
needs watering, is maintenance
Low impedance design with excellent cna^N
acceptance - no current limit with controlled^
voltage chargihg.
Shockproof high impact reinforced case restrains bulging.
iff® M ^ i|P c ■ . . Jl/. mI . 1 i * jj, JR™ J p - * \ y ' jBI
Copper alloy corrosion free connections for maximum conductivity.
Sun Xtender® Providing Safe, Reliable Power Solutions Worldwide Since 1987
Power when you need it
www.sunxtender.com
fiPi
Crafted for quality in the U.S.A
Sun Xtender® Batteries are Environmentally Friendly
- 1 00% Recyclable
AS 9100 REV. B:2004 and ISO 9001:2000
k'/ . J, 'V^ i.(jF vj fl 5 M
phone 626-813-1234 fax 626-813-1235 www.sunxtender:com
<► * .# t t J - r 1 'fyjV j : \ijfi J?' .
Concorde Battery Corporation
Join the Hottest Team
in the Solar Business!
solar experience support
you at every g • |
step.
Get everything you
need to deliver NEC-compliant
solar solutions - profitably
and on schedule!
What makes AEE Solar the fastest-growing
wholesale distributor in the renewable
energy business?
support
The most highly
respected technical
support and customer
service in the industry.
Our three decades of
training
Ongoing, comprehensive
dealer training - from
beginner to advanced,
online or hands-on,
regional and local. We help
you master the skills you
need to succeed.
products
Proven, tested
products at highly
competitive prices.
If AEE Solar carries it,
you know you can
count on it.
catalog
Our renowned annual
Renewable Energy Design
Guide & Catalog. Use the
industry’s most sought-after
resource as your own
powerful sales tool!
inventory
The widest inventory
selection in the
business combined
with just-in-time
delivery. We stock it all
so you don’t have to!
financing
Financing packages for
your customers. Close
more sales with convenient,
affordable renewable energy
financing.
Whether you are an industry veteran or a solar rookie, put AEE Solar
on your team for solar success! Call or apply online today!
www.aeesolar.com
The Only Wholesale Distributor You’ll Ever Need
800 - 777-6609 707-923-2277 1 1 55 Redway Drive
8:30 to 5:00 Pacific Time 707-923-3009 fax PO Box 339
Monday-Friday
sales@aeesolar.com Redway, CA 95560
<
June & July 2008
: 30 sustainable sailing
Derek Young
After using a noisy diesel generator for onboard electricity, Mike and
Joanne Young installed wind and PV systems on their 37-foot sloop.
,,.'"38 catching rain
Heather Kinkade
Keep your gardens lush and provide drinking water from rainwater
harvested on site. Expert advice on catchment system components.
* 46 carbon free
Mel Tyree
Mel and Charleen Tyree took the zero-carbon challenge, building a
home that's powered entirely with clean, renewable energy.
56 hydro penstock
Jerry Ostermeier
Maximize your microhydro system performance with sound pipeline
practices.
home power 125 /june & july 2008
Clockwise from lower left: Courtesy lari Woofenden; Mel Tyree; www.rainharvesting.com; Roger Webb; www.solarworld-usa.com; Suzanne Olsen; www.lorentzpumps.com
On the Cover
Mike and Joanne Young take renewable energy to
the seas, using a small wind turbine and a PV system
to meet most of their onboard electricity needs.
Photo by Roger Webb
66 string theory
Ryan Mayfield
For best PV system performance, size array strings to meet the
requirements of your inverter and climate.
• • *74 solar pumping
Erik Lensch
Solar-electric pumping systems offer an affordable, sustainable
solution for your water needs.
From Us to You
Home Power crew
Getting a grip on the grid
12
Ask the Experts
Industry professionals
Renewable energy Q & A
22
Mailbox
Home Power readers
Feedback forum
106
Code Corner
John Wiles
To fuse or not to fuse
112
Independent
Power Providers
Don Loweburg
Organizing the pros
116
Power Politics
Michael Welch
Getting FIT
120
Home & Heart
Kathleen
Jarschke-Schultze
Home field advantage
126
RE Happenings
128
Marketplace
130
Installers Directory
82 net zero
John Patterson
Harvesting sunlight to meet their lighting, electricity, and water heating
needs was a smart move for this Portland, Oregon-based company.
135 Advertisers Index
136 RE People
Meg Thomas
92 certified solar
Chuck Marken with Doug Puffer
Pick the perfect solar hot water system for your climate and site.
Home Power (ISSN 1050-2416) is published bimonthly
from offices in Phoenix, OR 97535. Periodicals postage
paid at Ashland, OR, and at additional mailing
offices. POSTMASTER: Send address corrections to
Home Power, PO Box 520, Ashland, OR 97520.
www. homepower . com
The OutBack Power Systems
FLEXnet™ DC is the ultimate in
DC System monitoring devices.
Our integrated networked
communications make valuable,
usable data available from your
system, providing you with the
answers you need concerning
your system's health,
performance and efficiency.
Power Systems
Corporate Headquarters European Sales Office
19009 62nd Avenue NE Barcelona, ESPANA
Arlington, WA USA +34.93.654.9568
+1.360-435-6030
from us to you
GETTING A GRIP ON THE GRID
In the early days of the magazine. Home Power's goal was to network a fledgling
off-grid solar movement. Our efforts created an ongoing information exchange that
helped build the foundation of today's solar industry. About a decade ago, our
focus shifted to bringing these proven technologies out of the backwoods and into
backyards by sharing information on the latest in grid-tied solar-electric systems.
After all, the vast majority of Americans live on grid, and in this wired realm, the
potential for solar energy borders on limitlessness.
But where bringing the benefits of RE to off-gridders has been straightforward,
interfacing solar technologies with the utility grid has been anything but simple.
Some issues have been technical, but many have been related to policy, legislation,
incentives, administration, and straight-out education about the impacts of
PV technology on the grid-tied world. Just like in the early days, increasing
communication between experienced and inexperienced users was key.
Along these lines, a recent report (www.solarelectricpower.org) published by
the Solar Electric Power Association and the Interstate Renewable Energy Council
caught my attention — and my imagination. The report was based on a survey of
utility practices related to residential-scale grid-tied PV. "Several utilities reported
thousands of PV systems. But the majority of utilities have not yet reached critical
mass," said Mike Taylor, SEP A director of research. One of the conclusions drawn
in the report is that solar-experienced utilities could assist utilities with little or no
experience with small-scale distributed generation.
The concept of experienced utilities helping inexperienced utilities smooth the
way for future PV installations is a fascinating indication of the momentum that's been
created. And looking at what's coming down the pike, it's a necessary development.
In the United States, installed PV capacity grew by 60% — 101 megawatts — between
2005 and 2006. As impressive as these figures are, a five-fold increase in domestic
PV capacity and the number of installations is projected over the next three to four
years.
Advances in equipment design and system installation are guaranteed in today's
competitive RE market, but information exchange, as pivotal as it is, isn't. If you have
RE experience, share it. In many cases, it's the most powerful thing you can do to
change the way we generate energy in the United States and beyond.
— Joe Schwartz for the Home Power crew
</>
P
cc
£
(0
U)
0
Year
Cumulative Current & Forecasted
U.S. PV Installations & Installed Capacity
300,000
< n
C
250,000
O
JS
200,000
+-•
</>
150,000
c
M—
o
100,000
5 _
0
Jd
50,000
0
E
3
z
Think About It...
"Information's pretty thin stuff unless mixed with experience."
— Clarence Day
www.outbackpower.com
home power 125 /june & july 2008
Source: Larry Sherwood, IREC (2000-2006 data); Travis Bradford, Prometheus Institute (MW projections); Mike Taylor, SEPA (number of installation projections)
*SP
rriax
l
t
£
..■..'V- • . .
l otf’,.
I
Ifll
i .4 «j
AVSA "1
C*J|.
tD-G-Ps 1
A.™ k'J
ie.2-.yp 1
Mi
Ml I l =i-.- ii |
rtutsBnck
Power System*
Built-in 1 23 Days of
Data Logging
fully OmBack Network
Integrated and
Programmable
Full flO Amp Output Capacity
in Ambient Temperatures
up to 104*F (40“Q
Easy to Replace,
23.9 Tear M-TSF
Cooling fan
Programmable 12 Vole
Auxiliary Output Signal
Advanced Continuous
Maximum Power Point
Tracking Algorithm
The latest innovation in Maximum Power Point Tracking (MPPT) charge controllers.
www.flexmax80.com
Power Systems
Publishers
Richard & Karen Perez
Executive Editor & CEO
Joe Schwartz
Managing Editor
Claire Anderson
Art Director
Ben Root
Senior Editors
Michael Welch, Ian Woofenden
Technical Editors
Justine Sanchez,
Roy Butler, Erika Weliczko
Associate Editor
Kelly Davidson
Graphic Artist
Dave Emrich
Solar Thermal Editor
Chuck Marken
Building Technology Editor
Rachel Connor
Transportation Editors
Mike Brown, Shari Prange
Columnists
Kathleen Jarschke-Schultze, Don Loweburg
Michael Welch, John Wiles
Advertising Manager
Connie Said
Advertising Director
Kim Bowker
Chief Information Officer
Rick Germany
Operations Director
Scott Russell
Data Manager
Doug Puffer
Customer Service & Fulfillment
Jacie Gray, Shannon Ryan
She’ll graduate
high school.
Copyright ©2008 Home Power Inc. All rights reserved. Contents may not be reprinted or otherwise reproduced without
written permission. While Home Power magazine strives to publish only safe and accurate content, we assume no
responsibility or liability for the use of this information.
Interior paper is made from 85%-100% recycled material, including 20%-30% postconsumer waste.
Your Fronius solar
Contact Us...
inverter will still be
covered by our new
15-year warranty*.
POWERING YOUR FUTURE
www.fronius-usa.com
* Call your Fronius representative
for pricing and details.
Subscriptions
To subscribe, renew, change, or inquire about
a subscription:
800-707-6585 or 541-512-0201
subscription@homepower.com
www.homepower.com/subscribe
Back Issues
Many of our back issues are available in print
and/or online in Adobe PDF. Our first 120
issues are also compiled on DVD-ROM.
More information at:
www.homepower.com
Order online or by phone:
800-707-6585 or 541-512-0201
Submissions
For inquiries and information related to
editorial submissions, write to us at:
submissions@homepower.com
www.homepower.com/writing
Marketing
Promotional opportunities and offers:
marketing@homepower.com
Ask the Experts
To have your technical questions considered
for publication, send them to:
asktheexperts@homepower.com
Web Site
www.homepower.com
Send your comments and suggestions
regarding the site to:
web@homepower.com
Advertising
For inquiries and information related to
advertising in Home Power or on
www.homepower.com, contact:
connie.said@homepower.com
541-512-0201
kim.bowker@homepower.com
541-858-1791
www.homepower.com/advertising
Letters to the Editor
E-mail your comments and suggestions
to us at:
mailbox@homepower.com
or write to the address below.
Home Power magazine • PO Box 520 • Ashland, Oregon 97520 • USA
Expect
higher
standards
J
15-year warranty now available from Fronius
Fronius, an innovative solar inverter company, is raising the bar with another first. As part of our
Fronius Gold Quality Guarantee program, we are offering a 15-year warranty* on all of our solar inverters.
Fronius’ priority is to manufacture the highest quality inverters available and now supports this with an
industry-leading 15-year warranty.
Enjoy peace of mind with your solar investment, knowing that you are covered for a full 15 years.
Take a look at what 60 years of experience can do for you.
Fronius USA LLC, 10421 Citation Drive, Ste 1100, Brighton, Ml 48116
Tel: 810-220-4414 Email: pv-us@fronius.com Web: www.fronius-usa.com
POWERING YOUR FUTURE
* Call your Fronius representative for pricing and details.
Alaska Solar
I live on-grid in Anchorage, Alaska, and I'd like to install solar-electric modules on
my roof. However, most of the information I can gather discourages their use in this
climate.
I'm willing to use conventionally generated electricity in the winter, but in the
summer. I'm sure there must be a way for me to rely solely on solar-generated
electricity. Anchorage also doesn't get as much rainfall as the southeastern region
of the state, and in summer, we receive 18 to 19 hours of daylight. Can you make
any suggestions for the type of system that would be economically feasible for me
to install?
Ann Pence • Anchorage, Alaska
Peak Sun-Hours
Compared
Avg. Daily
Peak Sun-Hours*
Location
Jan.
Jul.
Annual
Anchorage, AK
1.0
4.4
3.0
Seattle, WA
1.6
5.7
3.7
Los Angeles, CA
4.4
6.6
5.6
*Fixed array, oriented to true south, tilt = latitude
It's a fact that Alaska in general doesn't get as much solar radiation
as most locations in the southern 48 states. Still, if you installed a
700-watt array at a really good site, you could expect to generate
at least 550 KWH per year (per the solar performance calculator at
http://rredc.nrel.gov/solar/codes_algs/PVWATTS/). A ballpark
cost would be $6,000 to $8,000 installed, and would qualify you for
a $2,000 federal tax credit if your system was installed this year.
Unfortunately, the utilities serving Anchorage don't currently
allow net metering or offer any incentives. This means they would
pay at an "avoided cost" rate for electricity your system sends to the
grid in excess of your usage between meter readings. Avoided cost is
typically 4 to 8 cents per KWH, but may be less.
In Fairbanks, Golden Valley Electric Association started an
incentive program called SNAP (Sustainable Natural Alternative
Power) about two years ago. Based on the original SNAP program
started in Chelan County, Washington, this program offers up to
$1.50 per KWH to local renewable electricity producers who sell
electricity back to the grid.
Recently I heard that Chugach Electric in Anchorage and Homer
Electric in Homer will be starting their own SNAP programs this
year. You should contact your utility to see if any incentives are
available now or will be in the future.
If it turns out that PV just isn't economical enough at this time,
there are plenty of cost-effective energy-efficiency improvements that
you could make to your home. Look into the Anchorage Department
of Neighborhoods' Weatherization Program and the Cooperative
Extension Service in Fairbanks. Both are awesome resources for
information on energy-efficient living in Alaska.
Greg Egan, Remote Power Inc. •
Fairbanks, Alaska
home power 125 /june & july 2008
Courtesy remotepowerinc.com
They suffered from irreconcilable similarities.
You're concerned about the price of electricity. She's worried about global warming. You want less reliance on imported
energy. He wants more energy freedom. Well, at least you can agree on a residential wind generator. Designed specifically
for grid-connected homes, the Skystream 3.7 @ allows you to take control of your energy needs by converting the free
energy in the wind into electricity. Skystream can lower your electric bill by as much as 80%, protect you against volatile
electricity prices, reduce your dependence on foreign oil, and produce clean green energy that doesn't cause global warming.
Most importantly, it provides greater independence and stability for you and your family. This, we can all agree on.
SKYSTREAM 37
Visit skystreamenergy.com or call 1-866-807-9463 for a dealer near you.
Roof Replacement
I'd like to go into the business of installing rooftop solar energy systems on newly
constructed buildings, but I'm concerned about the problem of roof replacement twenty
years down the road. I can see a major disruption to PV modules and solar thermal
collectors during reroofing. Are there installation techniques that address this problem?
Fred Mocking • Skokie, Illinois
Since removal and reinstallation of roof-mounted solar equipment
can be quite expensive, usually requiring more labor hours than
the system originally took to install, the frequency of possible
roof replacement definitely needs to be considered. With new
construction, the first thing is to start with a durable roofing material
that has the longest life span you can afford. If you can install a roof
that will last 30 to 40 years (or more), its longevity will be right in line
with that of your solar energy system.
When it comes to purchasing a mounting system, I prefer to
use round-style mounting posts, which mount on the roof decking,
instead of feet made of angle stock (L-shaped mounting feet), which
mount on top of the roofing. Round posts are flashed and roofed
around just like a normal pipe vent. When it's time to remove and
then reinstall the system for a new roof, you don't have to remove the
mounting feet themselves, just the roofing material around them. If
you're replacing the roof and have used angle-stock style mounting
feet, you'll have to remove all the feet and will have to install your PV
array or solar hot water collectors from scratch after the new roof is
in place. Compared to angle-stock style mounting feet, round, flashed
mounting feet will likely be more watertight in the long run.
Roofs in general are not intended to be walked on. Installing solar
energy systems can result in substantial foot traffic on roofs, and even
new roofs can be damaged during this process, taking valuable years
off the life span of the roofing material. This is an especially important
consideration with composition (asphalt) shingle roofs. On hot days,
the asphalt will soften, making the shingles more vulnerable to
damage. If you must work on the roof during hot weather, wear flat,
soft-soled shoes instead of raised-heel work boots to avoid damage.
In all you do, remember to make safety your first priority —
working on roofs puts you at risk for serious fall hazards. Don't forget
to install permanent safety anchors when the new roof is going on,
and use harnesses and fall protection gear while installing systems.
Good luck, and work safe.
Kristopher Sutton, Sutton Solar • Paonia, Colorado
14
home power 125 /june & july 2008
water filled brushless DC motor
maintenance-free
no electronics in the motor
1 2-200V DC, 1 1 0-240V AC solutions
modular concept: pump end, motor,
controller are seperate parts
all 316 stainless steel,
not thinner than 0.16" (4mm)
2,000ft (600m) lift ability
pump speed adjustable
remote tank shut off with integrated
timer and pressure switch
largest variety in solar industry:
helical rotor, centrifugal, vane-type,
submersible, surface or floating pump
LO-RENJZ
LORENTZ Germany
www.lorentz.de
Dealers: CAP Solar Canada, www.capsolar.com, Tel. (866) 556 8779 (toll free), Fax (403) 556 7799
GENPRO USA, www.genpro.us, Tel. (866) 593 0777 (toll free), Fax (605) 341 9918
KELLN Solar Canada, www.kellnsolar.com, Tel. (888) 731 8882 (toll free) , Fax (306) 731 2774
Solar Power & Pump Co. USA, www.togosolar.com, Tel. (866) 246 7652 (toll free). Fax (580) 225 1 120
LORENTZ
SINCE 1993
SOLAR WATER PUMPS
Ask the EXPERTS!
Off Grid or Not?
I'm shopping for rural property, and have
looked at some parcels that are off the
grid — some a short distance from utility
lines and some a very long way. I don't
know a lot about solar- and wind-electric
systems, and hope you can give me some
guidelines to help compare the cost of
installing and owning a system with
the cost of utility line extension. When
is staying off grid — or connecting to the
utility — worth it?
Pete Little • Los Angeles, California
One of the main financial advantages to off-grid living is the lower
cost of land. But if you want electricity at your remote property,
be prepared to pay. Whether your money goes to a stand-alone RE
system or to the utility to bring in a line will be up to you and what
your end goals are. In some areas, the expense of line extension will
be prohibitive, making your decision to stay off grid easier. But if
connecting to the utility grid costs $5,000 or $10,000, your decision
may be a little more difficult.
Your first step should be to examine your motivations and goals.
While many people dream of being off grid, they often are not aware
of the responsibilities and ongoing costs. In most places, utility
electricity is inexpensive compared to making your own electricity
off grid, and when there's any maintenance or troubleshooting, you
just call the utility. Off-grid system owners must be prepared to take
on the utility's job, or pay someone else to do it.
So just how expensive is a residential off-grid electrical system?
This depends on several factors, including incentives, the renewable
resources available, and local installer pricing. But the biggest factor
is the one only you can answer — how much electrical energy do you
need? Here are some ballpark figures, and the resources to do your
own analysis.
According to a Lawrence Berkeley National Laboratory study,
the average house in your utility's service area used 5,900 KWH per
year in 1999. Consider the cost of powering that average home with
a PV system.
Using the PV output calculator (http://rredc.nrel.gov/solar/
codes_algs/PVWATTS/), with default settings for Los Angeles, a
system of 5 KW peak can meet the annual need, but you'll have 47%
more energy available in August than in December. Most off-gridders
do not try to size their system to provide all of their electricity in
the winter; instead they rely on a backup generator to make up for
reduced solar electricity generation. This hypothetical homeowner
may buy a smaller system that meets demand for a portion of the
year, and rely more on the engine generator during the winter.
As a very rough approximation, I use a total installed system cost
of $12,000 per KW peak for an off-grid solar system. So powering the
average home in southern California would require an investment of
about $60,000! Some incentives may apply, but few are applicable to
off-grid systems (see www.dsireusa.org).
Fortunately, most off-grid homeowners manage to live well
using much less electricity than the average homeowner. This is
accomplished with a mix of energy shifting (using gas or propane
instead of electricity), efficiency (Energy Star appliances and compact
fluorescent lighting), and conservation (turning off lights, no central
air conditioning, etc.). As a result, many off-grid households manage
with a PV system that produces about 1,500 KWH per year. In
California, this would correspond to a system of about 1 KW peak,
or $12,000.
If your site is blessed with a good average wind speed or a
flowing creek, a hybrid system is likely to cost less than an all-PV
system. But the output of a wind or hydro system is very site specific,
so I can't be more exact.
The lack of utility access can save you money when buying land,
perhaps enough to pay for your off-grid electric system, but you're
wise to "run the numbers" before you buy.
John Richter,
Institute for Sustainable Energy Education •
Bingham Farms, Michigan
16
home power 125 /june & july 2008
The right
fit matters
There is a Magnum Inverter/Charger to fit your needs
MM-AE Series
Inverter/Charger
Modified sine wave,
600- 1500 watts, 12-24VDC
Available models: MM612AE,
MM1212AE, MM1524AE
MS Series Inverter/Charger
Sine wave,
2000 - 4000 watts, 12 - 24 VDC
Available models:
MS2000, MS2000-20B, MS2012,
MS2012-20B, MS2812, MS4024
MS-AE 120/240V Series
Inverter/Charger
Sine wave,
4000 - 4400 watts, 24 - 48 VDC
Available models:
MS4024AE, MS4448AE
RD Series Inverter/Charger
Modified sine wave,
1800 - 3900 watts, 12 - 24 VDC
Available models: RD2212,
RD1824, RD2824, RD3924
Available Accessories:
Automatic Generator Start Module (AGS), Battery Monitor Kit,
Conduit Box, Fuse Blocks, Ignition Switch Lockout, LCD Remote Displays,
Remote Switch Adapter, Series Stacking Cable Kit
Call and ask for our full catalog for
complete product information.
Phone: 425-353-8833
Web: www.magnumenergy.com
awa^m w« mrawa
ENERGY
The Powerful Difference
Solar Radiator
I want to use a 3- by 8-foot solar water-heating collector connected to a radiator to
help heat an 8- by 10-foot room in my basement. If the water can reach temperatures
between 140°F and 150°F, it should be hot enough to serve this function. Then, it's just a
question of which type of radiator to use. I was thinking of using a standard baseboard
heater or maybe an old cast-iron radiator. Then I thought about the advantages of using
a thermal heat-storage "block" made of bricks. Hot water from the collector could be
circulated through the block, which would absorb and slowly reradiate the heat. What
do you think?
Paul Melanson • Nova Scotia, Canada
Your best bet for passive radiation is a baseboard element. Cast-iron radiators were designed
for steam heat — they'll work with hot water, but not as effectively as a baseboard element. It is
much more effective to use water as a storage medium than masonry block, because its specific
heat (heat content) is about five times that of brick's specific heat.
If you don't mind the cosmetic appearance, a solar collector heating an uninsulated steel
tank will make up a low-cost system. Make the system a drainback system and you'll just have
four components — tank, pump, control, and collector. From a quick glance at the sunlight
available in Nova Scotia, a 3- by 8-foot collector probably won't heat more than a 30-gallon tank
in the winter. The beauty of this system is its simplicity and the fact that the tank keeps adding
positive heat to the room down to 60°F or so.
Chuck Marken, AAA Solar • Albuquerque, New Mexico
Storage Tank:
30 gal., uninsulated
RE Family
While my wife and I are interested in using energy more efficiently,
and saving money doing it. I'm the one more interested in things
like solar electricity and solar hot water. While saving money
is an incentive. I'd like some advice from Home Power or from
other readers on how they discussed moving toward a more
renewable lifestyle with a spouse or significant other who isn't
quite as motivated.
R. Tomaro • via e-mail
When my husband Lance and I first got together, we were already
pretty well in agreement that we needed to take care of our own little
corner of Earth. Over the years, we've had long conversations about
our consumer society, and why we feel we need to do something
personally. Well, we are still discussing that one 17 years later, and
the list of what we plan to do comes out of our ongoing conversation!
So we're in agreement about the direction we want to go, and we
respect each other's reasons.
You two seem to be in agreement that it's important to try to
live more responsibly. That's significant, and it's a great starting
point for conversations. Each of you notices different symptoms of
the unsustainable direction our society is tending, and you can share
your observations as you gradually make your own decisions about
what steps to take in your lives.
Now the only question is, how do you choose to go about it?
People will order their lists differently, but assuming that your
spouse agrees with you about the big picture, maybe it's just a
question of what measures to start with. How about starting with
some smaller things that can have a big impact, like weatherization
or energy-efficiency upgrades? Maybe a more resource- and people-
friendly yard? For ideas, check out the local solar tour of homes in
your area (www.nationalsolartour.org). If you have kids, get them
involved in the decision-making process. When your spouse and
children see how pleasant this money-and-resource saving can be,
they will eventually want to take the bigger steps.
Jennifer Barker, EO Renew • John Day, Oregon
Debra Galandzy and Doug Horn implemented energy-efficiency
measures and installed a solar-electric system at their
Vancouver, British Columbia, home.
home power 125 /june & july 2008
SunWize
Grid-Tie
Systems
SunWize Grid-Tie Systems
offer the high-efficiency
Sanyo HIT 190/200W
solar panel.
The Ideal Solar Solution for Residential
and Light Commercial Applications
SunWize pre-packaged grid-tie systems and grid-tie
systems with battery backup contain everything you
need for a complete installation. SunWize Grid-Tie System
are easily installed on any type of composition or tile
roof. Multiple systems can be installed for higher power
output and some systems may also be expanded in the
future as budget or electrical requirements grow.
Many SunWize Grid-Tie Systems are certified by the
Florida Solar Energy Center (FSEC) for high quality, reliable
and safe operation compliant to the NEC. The FSEC
certificate is useful for permitting and field inspections
of installed systems. Contact us and find out how we can
help your business. Be successful, choose SunWize!
OFFICES THROUGHOUTTHE US AND CANADA
800.81 7.6527 • info@sunwize.com • www.sunwize.com
SunWize
Reliable People Reliable Products ::: Reliable Power!
ler Advantage
✓ Pre-Engineered Packaged Systems
✓ Superior Technical Support
✓ Free Jobsite Delivery*
✓ Product Shipment Nationwide
✓ Training Workshops
✓ Rebate Filing Assistance
✓ Lead Referral Program
✓ Marketing & Advertising Support
■ ^ „ : p r A <■ ■
A j ■■ -V
n
4 <■-» <-
-t . V ■
-a
, tf ♦ r; :
• J ?- j- -- ■■>!**"
Experience. Quality. Integrity.
‘ Within 1 00 mile radius of our branches
Solar PV / Solar Water Heating / Solar Pool / Radiant Floor Heating
(Homeowner and Business Owner Inquiries Welcome)
Petaluma, CA
800 - 822-4041
Sacramento, CA
800 - 321-0101
Corona, CA
800 - 680-7922
Mailbox
A Better Hydro Intake
I was disappointed not to see a simple, in-stream intake
included in Jerry Ostermeier's otherwise excellent article
in HP124. Using the Hydro-Shear Coanda effect screen from
Hydroscreen, I've installed simple, in-stream intakes multiple
times, by choosing a suitable spot in the stream, and either
building or inserting a screen box. Though these screens
weren't originally designed to be submerged, my experience
is that they work very well in this configuration if a vent is
included lower on the penstock to release trapped air.
I've used 1 square foot of the screen to collect more than
100 gallons per minute (gpm), which covers many home-scale
systems' needs. (The manufacturer claims it can collect 225 gpm
per square foot.) By avoiding building a dam, we not only reduce
the embodied energy in a hydro installation and minimize the
impact on the streambed, we also keep the impact on the stream
flow to a minimum, and don't impede fish. One of my intakes is
so well hidden that the house sitter couldn't find it, even when he
knew it was there.
I installed one that I only visit once a year for maintenance
checkups. I've found that the screens are very much self-cleaning.
Sometimes sand or pine needles will partially slow the intake. The
worst blockage I've seen was by algae growth in a sunny location.
An occasional scrub with a brush solves that problem.
Screens well anchored to large rocks need very little concrete
to make a robust intake that is immune to flash floods. The water
doesn't have anything to oppose it, and just flows over the top.
Chris Soler, Soler Hydro-Electric • Bow, Washington
"I've installed simple, in-stream
intakes multiple times, by
choosing a suitable spot in the
stream, and either building or
inserting a screen box."
Skip the Politics
In your editorial, "Waiting for the Sun" in HP123 , I noticed an
anti-Bush, anti-Republican tone. I must be blunt and let you
know I don't like that at all.
I don't care if you vote Democrat or Republican; I just don't like
the magazine to be infused with any politics. I pay to subscribe
for the sole purpose of improving our world, not to listen to your
prejudices about what one party did to another and what one party
has done for RE versus another. I don't need or want your help
in looking at these issues. If I want editorials on which party did
"better" than the other, countless magazines can give me that.
I don't want to read another boring, biased editorial. Please
just stick to RE untouched by bias (yours or anyone else's), and
let us read a magazine that helps get on with the job of RE.
Home Power is about solutions. Your editorial was not about
solutions. RE is about unity, not division. Your editorial was
about division, not unity. Both parties share the blame for the
mess we are in. Don't try to make it someone's fault when we all
share the blame. It serves no purpose.
Robert Montgomery • via e-mail
"Both parties share the blame for the mess we are in. Don't
try to make it someone's fault when we all share the blame."
home power 125 /june & july 2008
Trusted
10,654 miles from our test center
Customers rely on the long-term performance of our solar
inverters. That's why over 750,000 of them are in service
around the world. Our innovative engineers have developed
a complete range of inverters, all designed, manufactured,
and tested in Germany.
New product line now available
Complete range of 2007-UL-compliant inverters from 700
to 7000 watts, featuring integrated disconnect switches with
easier conduit knockouts, andtheSunny Tower, handling
36 to 42 kW, for simplified commercial installations.
10-year warranty now standard on 2007 inverter line.
Call us: (888)476-2872
www.sma-america.com
Rock Solid Solar
r
■ A
Mailbox
• committed to providing the
highest quality solar energy
solutions
• empowering individuals,
communities, & businesses
• contributing to a sustainable
future and clean energy
economy
Independence
You Can Afford
affordable solar
Hybrid Footprint
In regards to the article "Plug-in Hybrids" in HP121, the author points out that it is more
economical to drive a vehicle with batteries recharged with utility electricity than to
drive a gas-consuming vehicle. But being more economical does not mean you have a
smaller carbon footprint or that you're burning less primary fuel (usually combustible
fossil fuel). Because of inefficiencies in heat engines and distribution losses, typically
only about one-third of the energy in a combustible fuel is turned into electrical energy.
The article states that 1 gallon of gasoline is equivalent to 34 KWH of electricity. In
practice, 1 gallon of combusted gasoline will produce 11 KWH of electricity, not 34 KWH.
One of the comparisons the article makes is between an electric car and a hybrid Prius.
In the author's comparison, an electric car can travel 110 miles on 34 KWH, assuming 34
KWH is the amount of heat energy in a gallon of gasoline. But typically only one-third
of this energy can be converted to electricity. The electric vehicle's mileage is then 110
divided by 3, or 36.6 miles per gallon. The author points out that the Prius at 50 miles per
gallon costs twice as much to operate per mile.
With the author's assumption that most of the electricity generated in the United
States is produced using fossil fuels, the Prius will consume 35% less primary energy
than the electric car. However, because of the price structure, the electric car will cost
less to operate.
The amount of carbon put into the air while generating electricity will depend on
the type of fossil fuel consumed at the power plant. Per unit of energy, coal produces
66% more carbon dioxide (C0 2 ) than gasoline, and natural gas produces 20% less. The
article points out that half of our electricity comes from coal. If more of our electricity is
produced by renewables, the primary energy consumption and carbon footprint will be
reduced for the electric car.
One reason for an electric car's economic advantage is that there are fewer taxes on
electricity than gasoline. As a consequence, taxes will go up someplace else to pay for
our roads. In the article on my house in HP112, this point is discussed further in regards
to gas and electricity consumption for a home. For a home generating more electricity
than it consumes, the article looks at the relative merits of feeding this electricity into
the grid or using the excess electricity to reduce natural gas consumption. In California,
if you generate more electricity than you consume on a yearly basis, you are not paid
for the excess electricity you feed into the grid. In my home, I decided to feed my excess
electricity into the grid. This further reduced my carbon footprint but resulted in a larger
utility bill. My point is that the price structure does not always encourage the most
efficient way to consume energy.
Larry Schlussler, Sun Frost • Areata, California
The efficiencies of creating electricity depends
on the generator used. A large-scale power
plant will be more efficient than a small
engine. According to the U.S. Department of
Energy, well-to-wheel efficiencies (including
all transition stages, from raw materials to
motive power at the drive wheels) are 11%
for gasoline-fueled vehicles versus 17% for
electric vehicles. So whatever portion of
its energy a plug-in hybrid took from the
grid would be half again as efficient as the
gasoline burned in an internal combustion
engine (ICE) vehicle.
If you are going to look at the carbon
footprint of the grid-supplied electricity of
the plug-in hybrid and include the power
plant, then you will also need to include the
carbon footprint of the gas refinery in your
calculations for an ICE car, as well as the
tanker trucks that deliver it. Keep in mind
that gas refineries use an enormous amount
of electricity, so some carbon impact from
the electric power plant would have to
be applied to the ICE vehicle as well. It
is inherently more efficient to use the
electricity to directly power a vehicle than
to power a gas refinery to make gasoline to
power a vehicle.
The scale for greater efficiency (therefore,
lower pollution and carbon footprint)
proceeds in this order: gas vehicles to
hybrids to plug-in hybrids to grid-charged
pure EVs to renewable-energy-charged
pure EVs.
Shari Prange, Electro Automotive •
Felton, California
industrial solar
KEEKERS
www.affordable-solar.com
home power 125 /june & july 2008
Buy panels in bulk and save!
We offer a variety of panels from
the best manufacturers.
Discounts available if you are
interested in several pallets.
bp solar
SX-1 95B, 1 95w, 1 6v, Pallet of 20
evergreen solar
ES-1 80, 1 80w, 1 6v, Pallet of 30
^ KldDCERE
KD180GX-LP, 180w, 16v, Pallet of 20
SHARP
ND-21 6U2, 21 6w, 1 6v, Pallet of 28
BSUNTECH
STP1 70S-24Ab-l , 1 70w, 24v, Pallet of 44
Supplies are limited.
Pallet quantity varies by manufacturer, please call us for more
details. If there is another panel that interests you but it's not
listed here, please contact us.
Kyocera KD205X-LP
205 Watt 16V Nominal Solar Module
Kyocera is leading the solar
industry with the development of
the most efficient and cost
effective systems available.
Kyocera’s new and improved,
larger modules feature higher
output per module and maintain
the three-bus bar circuitry along
with d.Blue solar technology.
Our Price : $ 91 0. 00
KACO IkW
Complete Grid Tie System
The Krannich 1 kW Grid Tie
system includes almost every-
thing you need to start using
power from the sun! System is
expandable to 1 .7 kW.
Our Price : $ 6,399. 00
OutBack FLEXmax 80
Charge Controller
The FLEXmax 80 is the latest
innovation in Maximum Power
Point Tracking (MPPT) charge
controllers from OutBack
Power Systems.
Our Price : $ 580. 00
BP Solar SX3200B
200 Watt 1 6 Volt P V Module
High-efficiency photovoltaic
module using silicon nitride
multicrystalline silicon cells.
Our Price :$ 91 0.°°
1
■J
fit 1
SMA SB 7000US
7000 watt inverter
Increased efficiency means
better performance and
shorter payback periods.
Our Price : $ 3,953. 00
Xantrex XW6048-
120/240-60
Designed with consultation
and input from industry ex-
perts, dealers, and installers,
the XW sets a new standard
for battery-based inverter/
chargers.
Our Price : $ 3,485. 00
Air-X Land 24V
Wind Turbine Kit
The AIR-X builds upon what
has made AIR the world’s #1
selling small wind turbine with
new technology previously
found only in today's state-of-
the-art megawatt-class wind
turbines.
Our Price : $ 606. 87
*Please note pricing and availability subject to change in this crazy market
Call now toll free to order your way to a
Solar Energy Solution at 1 (800) 810-9939
or email us at sales@affordable-solar.com
You can also visit us online at vvvvw.affordable-solar.com
10+ years of experience & service
you can depend on and trust
• design • consultation
• financing • installation
affordable solar
Affordable Solar Group, LLC • 2501 Yale Blvd SE, STE 105 • Albuquerque, NM 87106 • (800) 810-9939 • www.affordable-solar.com
Mailbox
"I installed a heat
pump as a companion
to my more than 90%
efficient propane
furnace two years
ago, and have
documented overall
energy savings in the
25% to 30% range."
Hybrid Heating System
As a person who has worked in the HVAC
industry my entire life, I found your article,
"Home Heating Options," in HP123 both
accurate and informative. One option
that you did not suggest, much to my
surprise, was the hybrid gas furnace/air-
source heat-pump system.
Even in my home state of Wisconsin,
where the winters are extremely cold, a
hybrid system is a real energy saver and
has a very reasonable payback. Standard
air-source heat pumps are effective for
home heating with outdoor temperatures
down to 20°F, depending on the moisture
content in the air. I installed a heat pump as
a companion to my more than 90% efficient
propane furnace two years ago and have
documented overall energy savings in the
25% to 30% range. A dual-fuel controller
operates the furnace automatically when it
is too cold for the heat pump to be effective.
Using this combination, my propane
furnace did not come on until December
and did not operate after mid-February,
since the temperatures were above
24°F — the system's changeover point — the
majority of the time. On many days during
the winter, the furnace would run early
in the morning and the heat pump would
take over as the daytime temperature rose.
My heat pump is a standard 11 SEER, R-22
unit. Newer units coming onto the market
will offer better efficiency and better heat
transfer at low temperatures.
My 2,200-square-foot home has some
passive solar gain, and I am careful about
setting back the thermostat. With the
new system, over the past 12 months,
I have paid an average of $100 per
month for propane and $120 per month
for electricity, including heating or air
conditioning. This is with propane at $2.25
per gallon, and electricity at about $0,095
per KWH. I also installed a Bosch tankless
water heater, which has contributed to
my energy savings.
I enjoy your magazine a great deal
and have gained much knowledge
about renewable energy, which I plan to
incorporate into the next home I build. Keep
up the good work. I will look for an article
on hybrid heating systems in the future.
Mike Henry • Edgerton, Wisconsin
ABS Alaskan, fnc* introduces:
Water Turbines
Run^cf-river design for easy installation
- No dems, dnrtiSf&M. 04 , «iw^(Wp«!istocfcs r
Low rotational spaed for safer operation
- Lets potoftw demise to & totoine btedes
Easy installation in grid-Intertie & off-grid sites
- TtiVthVia-i nKluiSt compete fo wrfft' install M
5 kW, lOkW and 25 fcW systems available
- ItufWfWfl ssajy apemta in psreHai for larger systems
For more information abmit FtiCtirretii turbines, visit
www.tlhsilk.cmtl or contact us offline:
A ItS Aiaskntt , I nr,
2I.V Vbn Hen RJ. f - ~1 ■; f
jt*: m J* i: Wl7 45 1
(O'; WW-iy-ONHJ
4 fitS Distribution Center
i*4 -Usd Swn.Jfcffli'rt.
P 1151.5745 fiix. J35.il 1. 574S
tbit f-'trr b IS:
home power 125 /june & july 2008
Mailbox
Moving Toward Energy
Efficiency
I just discovered your magazine at the
library today and was excited to see
another source of information regarding
building an energy-efficient home.
We are hoping to sell our house
soon. I am being threatened with
legal action if I hang my clothes on a
clothesline (see The Wall Street Journal,
September 18, 2007).
One thing led to another, and we
decided rural living is more conducive
to our lifestyle. We feel this is an
opportunity for us to build green
and hang a clothesline without our
neighbors complaining.
I look forward to getting great ideas
for building a new house from your
magazine. In the meantime, encourage
your readers to hang their clothes out
on clotheslines to dry. Clothes dried in
the fresh air smell great, and you can
save up to 10% of residential energy use
by not using your dryer.
Susan Taylor • Bend, Oregon
Errata
In the wiring schematic on page 53 of HP124
we overlooked the positive grounding
requirements of the SunPower PV modules.
The positive (grounded) conductors should be
white. The negative (ungrounded) conductors
should be black in this configuration, and
routed through the array disconnect switch.
The correct wiring configuration is shown
below.
To send a letter to
Home Power's Mailbox,
write to: mailbox@homepower.com
or Mailbox, c/o Home Power
PO Box 520, Ashland, OR 97520
Published letters are edited for content and
length. Due to mail volume, we regret that
unpublished letters may not receive a reply.
DC Disconnect
Bigger, Better and
Maintenance Free!
IntxwlDciiiB the NEW L-18 Group Size • DC40O-8
NOW WITH A
5-YEAR SOLAR WARRANTY
From China's Premier Quality
manufacturer - Fullriver Battery
Mfg. Co. Ltd.
• True Deep Cycle Performance
and Longer Life
• Perfect for Solar, Back Up
Power and all RE Applications
• Non Hazardous - Non Spillable
Dual Terminals and Handles
• In stock in warehouses Coast to
Coast. Other unique models
and sizes are also available.
Contact us for a distributor near you.
phone:
1-800-522-8191
e-mail:
sales@fullriverdcbattery.com
See our complete AGM battery line up at
www.fullriverdcbattery.com
www.homepower.com
The MidNite E-Panel with two 63 amp breakers
imilar set up using OB Flexware 500 $1430 list, $
(Now save even more)
ich would you rather have, a nice new shiny box tl
wall or an even shinier, more compact system, an<
- — I $933 /_j
can be diverted
\ to buy a
PV panel or <
18 pairs of shoes
zn or? ^
OutBack mounted on a
MidNite Solar E-Panel
$549 list (E-Panel only)
120VAC version
Magnum Energy mounted on a
MidNite Solar E-Panel
$799 List (E-Panel only)
1 20/240VAC version
Check out
“E-Panels Explained”
on our website for
help in selecting the
best E-Panel for your
application
$ 01 / 11 ?, inc
Made in the USA
Trust nothing less than top quality American-made PV modules that provide
more kWh per kW than other major brands. By installing SolarWorld
Sunmodules, you're getting a superior value - more kWh foryour money.
In addition to superior performance, SolarWorld Sunmodules are lighter
weight and feature a sealed junction box with integrated locking connectors,
which makes them easierto install and completely reliable.
SolarWorld Sunmodules also carry a 25-year power warranty supported by
the largest manufacturer in the USA since 1977, so you get long-term
performance you can count on.
Maximize the value of your PV installation by using SolarWorld Sunmodules.
Call 1-866-226-5806 for a distributor nearyou.
SolarWorld California
4650 Adohr Lane
Camarillo, CA 93012
service@solarworld-usa.com
SolarWorld
THE SUNPOWERED COMPANY™
SolarWorld. And EveryDay is a Sun Day.
www.solarworld-usa.com
Off Shore
by Derek Young
photos by Roger Webb
Some say home is where you
hang your hat. Michael and
Joanne Young say home is where
you hang your PV modules — and
your wind genny. As they have
found, you can travel and have all
the comforts of home by bringing
along your own power company.
#hen Mike Young imagined his dream home, his
/ fantasy included one mast, two sails, a wind turbine,
ft and a solar-electric system. " I pictured my wife and
myself on a sailboat surrounded by blue water. I saw us
enjoying sunrises and sunsets day after day, breathing in the
salt air while listening to the ocean and watching the sails fill
with wind," says Mike, a native of Springfield, Vermont. "I
saw us living independently."
Fed up with Vermont's cold, dark winters, Mike fell in
love with the idea of escaping to the warm, sunny Caribbean
for part of the year. An avid sailor who spent many years
sailing on Lake Champlain and crewing on friends' boats, he
had the know-how to pull it off. All he needed was an ocean-
worthy vessel and a good first mate. "When he first told me
the idea, I thought he was crazy," says Joanne, his wife of
40 years. "But he was serious."
The couple bought Orion — a 37-foot sloop — and
upgraded its navigational, steering, and safety systems
for ocean cruising. They sold the family's retail propane
business and embraced the idea of early retirement at age
52. In 2000, Mike and Joanne made their maiden voyage to
the Caribbean islands. From Shelburne, Vermont, they took
Orion south to the Hudson River, which brought them to
New York City. From there, they followed the coast south
to Virginia, where they departed on the 11-day voyage to
Virgin Gorda.
Testing the Waters
The first trip gave newbie cruisers Mike and Joanne the
chance to get a feel for their energy needs. They left home
with a diesel engine set up to charge a 12-volt, 366 amp-hour
battery bank that powered the boat's electrical loads. Though
the engine worked well for cruising when winds were low
and produced more than enough energy for battery-charging,
it was less than ideal for generating energy for their day-to-
A noisy diesel engine used to spoil the ambiance at dinnertime.
With their RE systems in place, Joanne and Mike now
enjoy quiet evenings.
day needs — lighting, refrigeration, and hot water, and for
small household appliances, the navigation equipment, and
communication radios.
Running the engine a few hours each day to recharge the
battery bank burns about 1 gallon of diesel fuel — only about
90 cents on the islands — so it wasn't the expense that bothered
Mike and Joanne. It was the fumes and the noise. A diesel
engine likes to be run hard and hot, preferably over long periods
www.homepower.corn
sustainable sailing
Mike and Joanne's two-module PV system
and wind generator have significantly reduced
their reliance on the boat's diesel generator.
with a heavy load. But when it's used as a generator only, the
engine doesn't operate at its optimal temperature and burns
inefficiently, producing more pollution per energy output.
To add insult to injury, the warm Caribbean temperatures
doubled the energy requirements of the refrigerator and
freezer — two of the largest and most critical demands on the
batteries. Because they wanted to avoid paying for electric
hookups at marinas, Mike and Joanne found that they needed
to run the engine at least twice a day — about an hour during
the day and an hour at night — to charge the batteries and
meet their electrical loads.
"Have you ever heard or smelled a diesel engine?" Mike
says. "There was no room in my sailing fantasy for a smoky,
noisy diesel engine and all its pollution. The engine ruined
one too many cocktail hours on the deck. I looked around and
saw other boats with solar modules and wind turbines, and
knew what I had to do."
The battery monitor, conveniently located
next to the other electric controls.
Sustainability at Sea
For cruisers, who generally sail in areas where the sun and
wind are abundant, combining solar and wind power is a no-
brainer — especially when the alternative is burning diesel fuel
to charge batteries. "When you use the power of the wind to
move your home," Mike says, "you feel good. And when you
can power the rest of your needs with renewable energy, it
completes the picture."
In 2003, after talking with fellow cruisers and observing
different wind turbines at work, Mike purchased a wind
turbine manufactured by Kiss Energy Systems (KES) in
Chaguaramas, Trinidad. Designed for marine conditions,
the KISS (Keep It Simple Sailor) turbine is durable yet quiet
enough for the confined quarters of a sailboat. Elliptical blade
ends minimize tip noise, while a 9-foot tower mounted to the
stern provides plenty of headroom — nearly 7 feet.
Mike and Joanne saved on labor costs by installing the
turbine themselves. Instead of using the mast mount kit
offered by KES, they fashioned a mount from stainless-steel
pipe — which cut costs some but added hours to the project.
"Measuring, cutting, and fitting the turbine mount took
several days. What made the installation more difficult was
that we did it at anchor. It would have been much easier if the
boat was on land or docked, but we managed," Mike says.
Three blades make up the 58-inch-diameter rotor.
The aerodynamic fiberglass two-piece housing is hand-
molded in KES's Chaguaramas shop, as are the blades.
The manufacturing of the three-phase, permanent-magnet
alternator is subcontracted to local fabricators. The alternator's
three-phase AC output is, in turn, converted to DC for battery
charging. In typical 15-knot (17.3 mph) winds, the turbine
can produce up to 7.5 amps for the 12-volt nominal battery
bank. If batteries are full, the wind genny can freewheel or an
electrical brake can minimize the rotation in winds up to 30
knots (34.5 mph). Stronger winds require the freewheel mode,
and a thermal switch reduces the output and prevents the
alternator from overheating.
Because the turbine does not include additional regulation
other than the thermal switch, manually furling the turbine
is necessary to prevent excessive battery voltages. Mike does
home power 125 /June & july 2008
sailing
Young Off-Grid PV & Wind System
Photovoltaic Array:
Two, Shell SQ80,
80 W each at 17.5 Vmp,
wired for 160 W total
at 17.5 Vmp
WindTurbine:
KISS, 58-in. rotor diameter,
7.5 A at 12VDC at 15 knots (17.3 mph)
DC Array
Disconnect:
15 A
breakers
1 1
i —
:d :
)
j v.
DC
Load
Panel
Charge Controller:
Morningstar SunSaver, 10 A
• SunSaver-io
Battery Bank:
12VDC,
366 AH total
Inverter/Charger:
Xantrex Freedom Marine 10,
1,000 W, 12VDC input,
120 VAC mod. square-wave output
AC Load Panel:
To 120 VAC loads,
automatic
neutral/ground
bond internal to
inverter
Battery/ Inverter
Overcurrent
Protection:
200 A, classT fuse
Note: All numbers are rated, manufacturers' specifications, or nominal unless otherwise specified.
PV & Wind Systems Tech Specs
Overview
System type: Battery-based solar- and wind-electric
Location: New England to Trinidad
Solar and wind resource: Varies with location
Photovoltaics
Modules: 2 Shell SQ80, 80 W STC, 17.5 Vmp
Array: Two modules in parallel, 160 W STC total, 17.5 Vmp
Array installation: Self-fabricated flush mounts made from
stainless-steel tubing, installed horizontally over the boat's
cockpit
Orientation: Varies with the movement of the boat
Wind Turbine
Turbine: KISS (Keep it Simple Sailor)
Rotor diameter: 58 in.
Rated energy output: 7.5 A, 12 VDC nominal, at 15 knots
(17.3 mph)
Rated peak power output: 25 A at 12 VDC nominal
Mount: Home-built stainless-steel pipe, rubber-mounted on
the stern
Energy Storage
Batteries: Two Deka 8G4DM, 12 VDC nominal, 183 AH,
sealed gel
Battery bank: 12 VDC nominal, 366 AH total
Balance of System
Charge controller: Morningstar SunSaver, 10 A
Inverter: Xantrex Freedom Marine 10, 1,000 W, 12 VDC
nominal input, 120 VAC modified square-wave output
Battery capacity metering: CDM Systems BT2000
www.homepower.corn
Living the good life.
not worry too much about overcharging the batteries, since
he's never far from the boat for long. On the rare occasion
when the turbine needs a break or, in trade winds, makes
too much noise, he stops the rotor manually by switch. "If
we're lucky enough to make that much
energy, it's time to do some ironing,
use the microwave, or make some other
use of it," he says.
Off-Grid Self Sufficiency
"When traveling in remote places, you are forced to become
a jack of all trades — an electrician, plumber, diesel mechanic,
and handyman, all in one," Mike says. "My best defense is to
be prepared for anything. I've done my research, and I can
handle most repairs that arise. So far, so good."
Mindful of the elements, Mike took extra care when
wiring both the wind- and solar-electric systems — twisting,
taping, and heat-shrinking all connections. "The salt air can
be brutal on mechanical systems of any kind," he says. "So
long as the wire connections are sealed properly, then you
have very few problems and the systems are easy — virtually
maintenance free."
Well, almost. . ."There are a lot of seagulls, and we have to
clean the droppings off the modules. If we're lucky enough to
have fresh water, then we just hose off the modules now and
again," he says. "But it's not so bad. I'll take bird droppings in
the Caribbean over Vermont's snow and ice any day."
Thanks to their wind- and solar-electric systems, Mike
and Joanne enjoy all the comforts and conveniences of home
with cleaner, quieter power sources. "Solar does great in
the daytime," Mike says, "but at night, when energy needs
are much higher, the wind takes over." The sun is fairly
Indoor lighting and television, powered by renewable energy.
Because the position of the boat is always changing and
shadows are inevitable, the placement of the modules is not
critical to the system's overall performance. "On a boat, it's
usually a matter of finding free space where the modules
are out of the way and won't get damaged," says Mike, who
chose not to tilt the modules, and instead, flush-mounted
them to the bimini frame. "I probably could have gotten
slightly better performance if I'd made the mount adjustable,
but the sun is so strong and the days are so long here that the
slight gain didn't seem all that important."
Solar in Safe Harbor
"It's a double-edged sword with wind,"
Mike says. "We like the wind, and we
need the wind, but we also like to get out
of the wind." Before, anchoring in low-
wind spots or seeking shelter in harbors
meant that the couple had to rely on the
diesel generator. For that reason, Mike
chose to supplement the wind generator
with a simple solar-electric system — two
Shell 80-watt PV modules mounted
horizontally on the bimini (awning) over
the cockpit. He purchased the modules
from Marine Warehouse in Trinidad,
and sourced from a local hardware
store the electrical cabling and other
parts — stainless-steel tubing, mounting
brackets, and nuts and bolts that resist
the corrosive effects of salt water.
home power 125 /june & july 2008
consistent, but when there is not adequate wind, Mike and
Joanne still must offset energy usage by running the engine
to charge the batteries. On its own, the solar-electric system
produces about 55 amp-hours (AH) per day on average — shy
of their 70- AH usage. "One more PV module, and we'd be
perfect," Mike says. "I just need to make room for it."
Currently, the 12-gallon hot water tank is fitted with a
heat exchanger that uses waste heat from the diesel engine
to heat water for domestic use. When Mike and Joanne need
to replenish the hot water, they run the engine, usually every
third day for about an hour. Though the engine only burns
about a half gallon of fuel — about 45 cents' worth — in that
hour, that's one hour and one half gallon too much for Mike.
He has devised a plan to add a custom solar hot water system
off the stern. Tapping into the existing plumbing will be fairly
easy, he says, but coordinating the shipping of the unit to the
islands will require some patience. "This," he says, "is the last
piece. Then we'll be totally independent."
On the Horizon
For the past eight years, Mike and Joanne have spent every
winter island-hopping around the Caribbean. By living
simply and relying on renewable energy, they keep their
expenses down. They anchor at out-of-the-way places and
catch their dinner most nights. One yellowfin tuna feeds the
couple for days, and they trade what they can't store for other
sustainable sailing
goods. Though the couple only saves an estimated $15 per
week by offsetting their diesel fuel use, every dollar helps
perpetuate their cruising lifestyle.
For the rest of the year, the couple returns to their home
in Springfield, Vermont. "We have the best of both worlds
right now," Joanne says. "When this all started, he had to
drag me down here kicking and screaming, but now I love
this lifestyle — seeing all the different places, meeting the local
people, and hanging out with fellow cruisers. Living by the
wind and the sun — I wouldn't have it any other way."
Access
Derek Young (seagoatmusic@gmail.com) is a freelance writer and
musician who dabbles in renewable energy. He lives in a solar-
powered camper in an undisclosed, off-grid location in Vermont.
System Components:
East Penn Manufacturing Co. • www.eastpenn-deka.com • Deka
batteries
Kiss Energy Systems • www.kissenergy.com • Wind turbine
Morningstar • www.morningstarcorp.com • Controllers
SolarWorld • www.solarworld-usa.com • PV modules
Xantrex • www.xantrex.com • Inverter/charger
gro Solar
What the World Needs. NOW*
Do flat roofs torment you?
Are flat roof mounting system lead times and
customer service issues causing you heartburn?
Would you like to install more product faster?
PanelClaw™ has heard you!
Developed by a leading installer and exclusively distributed by groSolar.
Stop the torment!
Coming soon...
Call us for more information:
8oo CO SOLAR (800.467.6527) groSolar.com PanelClaw
■ ®
gro
brilliant energy
solutions™
www.homepower.corn
♦ MITSUBISHI
ELECTRIC
SDLAR ELECTRIC INNOVATIONS
powered by the sun
With more than 33 years of experience in the
solar electric industry, Mitsubishi Electric is an
industry leader in developing high-efficiency
photovoltaic modules that deliver clean,
reliable energy to homes and businesses.
Mitsubishi Electric has made a commitment to
protecting the environment and we are proud
to use 100% lead-free solder in our solar
panels. For more information, please call
714-220-2500 or visit our website:
www.mitsubishielectricsolar.com
Solahart has been
designing and building
Hot Water Free from the Sun
solar water
heaters since
1953. The Solahart
brand is backed by
Rheem, the leading
water heater
manufacturer
in the world.
• Simple and reliable
passive thermosiphon
systems
• Open and closed
loop systems for
installation in almost
any environment
For more information
on Solahart systems
and dealers, call
334 - 260-1525
or email us at
solar@rheem.com
Dealer inquiries
are welcomed!
Hot Water Free from
the Sun™ is a trademark
of Solahart Industries
Pty Ltd
Solar
Water Heaters
built by Solahart
and backed by
Rheem!
Solahart systems
QG-300 certified by SRCC
Rheem Water Heating | 101 Bell Road | Montgomery, AL 36117-4305 | www.rheem.com
RH 120607
Average Annual Rainfall
| More than 96 inches
H 64 to 96 inches
EH 32 to 64 inches
□ 16 to 32 inches
□ 8 to 16 inches
□ Less than 8 inches
Adapted from Design for Water
by Heather Kinkade
ike it or not, drought is becoming more common in
many parts of the country. As dropping water levels
b n rivers and aquifers put the squeeze on freshwater
stores, municipalities are tightening their belts, raising
rates, and even implementing water-use restrictions. This
past spring, Raleigh, North Carolina, residents and others
in six surrounding towns were under "stage 2" water
restrictions — no lawn sprinkling, no car washing, and no
pool filling. Similar curbs are becoming more prevalent
across the country.
Even those who rely on well water aren't escaping the
consequences, as underground water tables drop below the
reach of many wells. In 1999, a drought in the Northeast
lowered water levels below their pumps in hundreds of wells
in two New Jersey counties. Three years later, the prospect
of parched wells pitted farmers against city dwellers of
Cheyenne County, Nebraska, in an effort to secure water.
And the situation is not getting better. According to a 2007
report by the U.S. Geological Survey, underground water
supplies all over the United States are continuing to shrink.
Some people are looking to the skies: catching and storing
rainwater. A rainwater harvesting system can reduce the need
and cost to pump groundwater, and can be less expensive
than tapping other water sources. It also provides a close-by
water supply that contributes to self-sufficiency. Rainwater is
"soft" water that's low in mineral content, which helps reduce
buildup in your home's plumbing. In coastal areas where
saltwater intrusion into aquifers is a problem, catchment
becomes even more important. And, in some places, installing
a rainwater system makes you eligible to receive rebates for
reducing your use and dependency on municipal water.
System Components
Rooftop rainwater harvesting systems are easy to construct,
operate, and maintain. Whether it is large or small, a rainwater
harvesting system has six basic components:
1. Catchment area: The surface upon which the rain falls,
generally a roof or impervious pavement.
2. Conveyance: The channels or pipes that transport the
water from the catchment area to storage.
3. Roof washer: The systems that filter and remove
contaminants and debris, includes first-flush devices.
4. Storage: The tanks where collected rainwater is stored.
5. Distribution: The system that delivers the rainwater for its
end use, either by gravity or pump.
6. Purification: The equipment that filters and distills, as well as
additives that filter and disinfect the collected rainwater.
home power 125 /June & july 2008
catching rain
Catchment Area
Although rainwater harvesting for nonpotable use can be
accomplished with any type of roofing material, for potable
use, the best roof materials are metal, clay, or concrete.
Water for drinking purposes should not be collected from
roofs containing zinc coatings, copper, asbestos sheets,
lead, or asphalt compounds. For flat or semi-flat roofs, an
acceptable roofing material for potable water catchment
systems is Weather Barrier Raincoat 2000 (www.haleypaint.
com), a coating product approved by the National Sanitation
Foundation (NSF).
Catchment Area
Length (ft.) x Width (ft.) x Annual Rainfall (in.) x Surface Area
Efficiency x 7.48 gal./ft 3 = Annual Catchment Area Runoff (in gal.)
A rainbarn describes an open-air shed with a large roof
area to catch rainwater. The structure can also provide
shelter for a variety of uses — a patio, carport, hay storage, or
farm equipment storage — thereby serving multiple functions.
Typically, the rainwater storage cistern is housed under a
rainbarn.
The quality of the captured rainwater depends, in part,
upon catchment texture: The best water quality comes from
Rainwater Regs
Several communities are enacting regulations and
guidelines for dealing with rainwater harvesting. In
Arizona, the towns of Tucson, Flagstaff, Chino Valley,
and Pason have enacted ordinances encouraging the
use of harvested rainwater. In Washington state, Seattle
and Friday Harbor, as well as King County, have recently
established their own guidelines.
Currently, the American Rainwater Catchment
Systems Association is working with several national
organizations to come up with general ordinances that
communities can revise and adopt. Texas has state
legislation dealing with rainwater harvesting and, along
with Hawaii and Virginia, offers rainwater harvesting
guideline booklets (see Access).
The Uniform Plumbing Code has an appendix dedicated
to rainwater systems, with sizing guidelines for gutters,
downspouts, and lateral pipes. The applicable plumbing
code should be reviewed for any design of rainwater
conveyance systems.
smooth, impervious catchment or roofing materials. Quality is
also determined by rainfall pattern and frequency. The greater
the storm event (i.e. the rainfall extent) and the shorter the time
between storms influence the cleanliness of the catchment area.
Greater rainwater volumes and frequencies will transport fewer
pollutants to the first-flush device and to storage.
Rainwater is slightly acidic, which means it will dissolve
and carry minerals into the storage system from any catchment
surface. For systems intended for potable water, first test the
water collected from the proposed catchment surface to
determine its contents. In some cases, filtration can remove
some contaminants. In other cases, the catchment surface
must be reevaluated or amended.
Conveyance
A common rainwater conveyance system features gutters
with downspouts that direct rain from rooftop catchment
Roof Surfaces for Potable Gaichmeni
Yes — Painted metal Yes — Ceramic or concrete No — Wood shingles No — Asphalt No — Galvanized or copper
www.homepower.corn
catching rain
surfaces to cisterns or storage tanks. The materials for gutters
and downspouts range from vinyl and galvanized steel to
aluminum, copper, and stainless steel. At a minimum,
gutters should be 5 or 6 inches wide, with an outer edge
higher than the roof-side edge and splash guards at roof
valleys. Gutters should slope toward downspouts at 1 /16
to 1/4 inch per 10-foot length of gutter, and be installed
per manufacturer's guidelines for hangers and connection
points.
Downspouts should have 1 square inch of outlet
(downspout) for every 100 square feet of roof area
to be drained — a 4-inch-diameter downspout can drain
approximately 400 square feet of roof area. Add more or
larger downspouts for larger collection areas. A typical
connection material from a downspout to a cistern is a 3- or
4-inch-diameter, schedule 40 PVC pipe or ABS pipe, which is
considered a more environmentally friendly plastic. However,
for potable rainwater collection, PVC or stainless steel should
be used. It is made from new material, not recycled material
Leaf screens are the
first defense in keeping
debris out of your system.
What’s a Rain Head?
The filtering process can be augmented by using a rain
head — a downspout that incorporates a self-cleaning
system. This unit has a funnel topped by a screen, which is
set at an angle of about 33 degrees to the lower horizontal
edge of the funnel. As the water washes over the angled
screen, the debris is forced toward the screen's lower
edge and away from the building, while most of the
rainwater continues through the funnel screen.
that may have picked up contaminants from its previous
use. Coated aluminum downspouts are also acceptable for
potable water collecting. Avoid ABS, DWV PVC, copper,
lead-containing, or galvanized pipes.
To keep leaves and other debris from entering the system,
the gutters should have continuous leaf screens made out of
1 /4-inch wire mesh or an equally efficient product covering the
entire length of gutter. Installing leaf screens will help reduce
system maintenance, reduce mosquito-breeding habitat, and
eliminate the need for frequent ladder-climbing to clean the
gutters. Downspout filtering rain heads, such as the Leaf
Beater and the Leaf Eater, provide a second chance to capture
and remove debris that might enter a storage system.
First-Flush Diversion
Downspout:
From gutter
40
home power 125 /june & july 2008
catching rain
Basic Potable Rainwater Catchment System
Roof Washing
Roofs, like other large, exposed areas, continuously receive
deposits of debris, leaves, silt, and pollutants on their surfaces.
One or several components can be used to filter or collect
debris and soluble pollutants, including gutter leaf-guards,
rain heads, screens, and/or first-flush devices. First-flush
devices are important when rainwater is collected without
the use of gutter leaf-guards, leafslides, or rain heads, or if the
rainwater is to be used for human consumption.
The simplest roof-washing system is a first-flush device
that consists of a standpipe (the diversion chamber for
collecting the initial rainwater runoff) and a gutter downspout
located prior to the cistern or storage tank inlet. When the first
rainfall enters the standpipe, the pipe fills, and a floating
ball seals the entrance to the diversion chamber, sending
rainwater to the cistern. Because a typical standpipe does not
automatically outlet to a storm drain, a screw-on cleanout
plug should be located at the end of the standpipe. If it is not
the self-draining variety, the standpipe should be emptied
after each rain event. This will eliminate standing water
from becoming foul from debris and soluble pollutants, and
thereby contaminating future collected rainwater.
Another diversion device is a roof washer, which consists
of a 30- to 50-gallon box, with leaf strainers and a filter, placed
just ahead of the storage tank. Several models of roof washer
are commercially available. Regardless of which type you use,
cleaning the washer is imperative. Otherwise, clogging can
result, restricting the flow of rainwater, and the stagnant water
can encourage pathogen growth.
Storage
Cisterns or storage tanks represent the largest investment in a
rainwater harvesting system, since already-existing buildings
have most of the other components: a roof, gutters, and
downspouts.
Above-ground tanks are available at most farm-supply
and building centers. They allow for easy inspection and
water extraction /draining by gravity. However, they also
A storage tank with a SafeRain first-flush diversion valve,
which operates on flow rate instead of initial quantity.
www.homepower.corn
41
Courtesy Heather Kinkade
catching rain
Rainwater Harvesting Costs
Typical Capacity
A.
Collection
Estimated Cost
/Size
1
Gutters
$0.30-$12.00
/lineal ft.
—
Roof Washing
This 8,800-gallon, galvanized storage tank requires a lining to
make it suitable for potable water.
take up yard space, can be expensive, and are susceptible
to damage from constant exposure to the elements. Below-
grade storage systems generally are reasonably priced,
although you'll have to budget for excavation expenses. They
require little or no above-ground space, and permit thinner
cistern walls due to the support of the surrounding ground.
However, extracting water from below-grade systems is more
difficult — requiring a pump unless a tank is buried on a hill
above its end use — and leaks and failures are more difficult to
detect. In addition, tree roots or overhead traffic may damage
a below-grade storage system.
Whether you go with above- or below-ground, a cistern
that is kept cool and devoid of sunlight allows water quality
to increase with time. When photosynthesis cannot take place,
most organisms die as their food source is eliminated. With
each rain event, a new supply of sediment and organisms
A variety of pumps
are acceptable
for rainwater
distribution. This
submersible pump
has a floating
intake to avoid
sediment on the
bottom of the tank.
Vertical or horizontal
box roof washers
$460-$ 1,000
—
Storage
Precast concrete or
ferro-cement tanks
$0.35-$1 .50/gal.
Any
Fiberglass
$0.50-$2. 00/gal.
500-20,000 gal.
Steel, corrugated &
galvanized with liner
$0.30-$2.79/gal.
150-104,000 gal.
Polyethylene
$0.50-$1. 90/gal.
210-5,000 gal.
Polypropylene
$0.35-$1. 00/gal.
290-20,000 gal.
Welded stainless steel
$0.80-$4.00/gal.
Any
Wood
(treated, with liner)
$0.88-$2. 06/gal.
Any
Stone
Up to $1.00/sq. ft.
Any
Invisible structures
underground retention
reservoir
$8.00/cu. ft.
Any
Atlantis underground
storage tank
$4.84-$5.15/cu. ft.
Any
Conveyance
Prefilters
$50-$80
—
Pressure tanks
$200-$1,000
—
Pumps
$500-$600
0.75-1.00 hp
Filtration
Cartridge filter sets
$100
—
1-micron filter
$265
—
Reverse-osmosis filters
$400-$1,500
—
UV filters
$300-$1,000
—
Ozone disinfection
system
$700-$2,600
—
Chlorine disinfection
systems
(automatic dosing)
$600-$1,000
—
Chlorine disinfection
system (manual dosing)
$1. 00/dose
—
will enter the storage unit. The sediment, while not usually
unhealthy, can initially discolor and flavor the water, but will
ultimately settle to the bottom of the storage container. It is
best to remove water from a cistern or tank at a position that
is farthest from a runoff inlet to allow settling before the water
is used. Some storage containers may require baffles, inflow
smoothing filters, or turbulence dissipaters to slow remixing
with the aged water.
Distribution
Stored rainwater may be conveyed (or distributed) by
gravity or by pumping. If a tank is located uphill or
above the point of use, gravity may work. Most plumbing
fixtures, appliances, and drip irrigation systems require at
home power 125 /June & july 2008
catching rain
least 20 pounds per square inch (psi) for proper operation.
(Standard municipal water pressures are typically in the
40 psi to 80 psi range.) As a general rule, water gains 1 psi
of pressure for every 2.31 feet of rise, which would mean
positioning a storage cistern almost 100 feet above the house
to achieve typical household pressure.
In most installations, placing a tank above its point of use
will also place it above the source, which is often the roof of
the building where the end use is. Because of this, pumps,
rather than elevated tanks, are typically used to extract both
below-grade and above-grade stored water. Submersible
or at-grade pumps may be used in any rainwater storage
system. Self-priming pumps with floating screened intakes
and automatic shutoffs — for times when water levels are
insufficient — are recommended.
Generally, well pumps or any type of submersible
pumps, as well as a pump located outside the tank, can
be used to transfer the rainwater out of a tank. Some
pumps keep the line pressurized, eliminating the need for a
pressure tank. When the rainwater is brought into a house, a
pressure tank is typically used in combination with a pump.
Using a pressure tank saves wear and tear on the pump by
reducing its run-time.
Purification
Rainwater intended for human consumption (potable) should
be screened, settled, filtered, and disinfected. When stored
water is being used, sediment filtration should be a maximum
of 5 microns, followed by a 0.5-micron carbon filter or an
equivalent 1 -micron absolute filter. These ultrafilters should
be NSF approved for cyst removal, since youTl want them to
remove disease-causing giardia and Cryptosporidia.
Specifically designed for potable rainwater filtration,
the AquaEst RainPC MK II removes bacteria, and organic
and inorganic contaminants.
Solar Purification
Solar water distillation systems are among the
simplest water purification systems available. No
filters or membranes are required, no moving parts
are used, and no electricity is needed.
Solar stills have a shallow pan with a sloping glass
cover. Water is directed to the pan where it is heated
by the sun. The water evaporates from the pan, rises,
condenses on the underside of the glass cover, and
runs down its slope into a collection trough and
into a clean container for storage. The contaminants
left behind in the pan should be flushed regularly.
Solar stills can be mounted on roofs or on ground
structures.
Most common filters are designed to be used with
municipal supplies and do not have a convenient method of
monitoring when they have become overloaded and are due
for replacement. For safety's sake, filters connected to a cistern
system should be changed more frequently than suggested by
the manufacturer. Rainwater used for potable systems should
be lab-tested periodically for quality.
Access
Heather Kinkade is a land-use planner, LEED accredited professional,
and registered landscape architect in Arizona, and the author of the
award-winning Forgotten Rain. She is president of Forgotten Rain
LLC, a rainwater harvesting and stormwater reuse company. This
article was adapted with permission from her most recent book on
rainwater harvesting, Design for Water ( New Society, 2007).
www.homepower.corn
Clean energy made ...clean!
Our commitment to clean energy goes
way deeper than just the quality inverters
we manufacture. Our entire corporation is
dedicated to implementing and innovating
green business practices from the inside out.
You see, we believe clean energy
products should be made with clean
energy. KACO’s onsite PV systems
generate more than 100% of the
electricity that we use on an annual
basis. Our onsite Biomass Com-
bined Heat & Power Plant provides
1 00% of our heating needs.
KACO also provides employees
free public transportation passes,
electric vehicles and bicycles for
their commute. We have even
started to plant trees to further
meet our goal of carbon neutral
manufacturing.
We believe quality clean energy
components should be made clean.
Learn more about our commit-
ment to clean energy and other
important company develop-
ments at www.kacosolar.com/zero
emissions.php
www.kacosolar.co
415 . 931.2046
KACO
It's not only a quality promise, it's a
If
T ^ i
1
1 i I
i
MBiW
-j
i fit y i
Our passion for solar energy has made us a world
leader in the field. State-of-the-art designs and rigorous
quality control result in products that meet the highest
international standards. We deliver increased energy
efficiency and environmental benefits, backed with
dedicated service. Because with Suntech, you can rely
on the product and on the people.
B SUNTECH
Solar powering a green future ™
www.suntech-power.com
Climbing the
Energy Everest
The Ups & Downs of
Creating a Net Zero-Energy Home
by Mel Tyree
6
home power 125 /june & July 2008
! : U \ ■ I Li
r ■
The Tyrees' barn
was designed
to perfectly
accommodate a
10 KW PV array.
carbon free
Living plants rely on solar energy
as their primary energy source, so
why not a house? In July 2000, my
wife Charleen and I set our sights
on building a net zero-energy
home. Our goal was to demonstrate
that you can operate a comfortable,
modern home — even in a climate-
challenged location — without
burning anything.
I
A t the start of the project, I was inexperienced in
building design. But I had spent much of my
career in biophysics immersed in numbers and
calculations, working to quantify the exchange of energy and
matter between sunlight, the environment, and plants. When
I began running energy systems design calculations for our
new home, I was amazed by how well my years of seemingly
unrelated research had prepared me for the journey ahead.
Along the way, we had to overcome some unique regulatory
and technical challenges, but, in the end, patience and
determination gave way to a carbon-neutral home that
derives 100% of its energy from the sun and wind.
The motivation to build our zero-emission home came
from the desire to reduce our contribution to global warming
and pollution. That meant eliminating our home's dependency
on all conventional fuels. Homes with solar- and wind-electric
systems commonly rely on natural gas, propane, heating oil or
firewood for cooking, as well as water and space heating. We
wanted to prove that it is possible to live in a home that offsets
100% of its energy with renewable, nonpolluting sources.
The first step was to find a location for our new home.
Over several months, we came across four suitable properties
in our home state of Vermont, but our potential neighbors
were opposed to the notion of having a wind turbine in their
backyard. Eventually we widened our search to the North
Country of New York, where we found a beautiful, affordable
property that met our needs — 102 acres of forest and pasture,
in Ellenburg, just north of Adirondack Park at 44.9° north
latitude.
New York state's net-metering law for residential RE
systems allowed excess energy credits to be carried forward
to the end of the annual billing cycle and supported property
tax exemptions for the systems' value. In addition, the New
York State Energy Research and Development Authority
www. homepower . com
r A
carbon free
Erecting the tower — 10 feet at a time. Final section — 120 feet up. Hoisting the rotor.
(NYSERDA) offered generous financial incentives for both
PV and wind systems. Based on some initial conversations,
neighborhood support for wind generators seemed positive.
I also learned that the town of Ellenburg has no zoning
regulations that prevent erecting a 120-foot tower for the
wind genny. Our project's future looked bright. We closed on
the property in October 2003 and were on our way.
Our Big Picture Energy Plan
Offsetting 100% of our energy needs would be no small
feat given the cold, cloudy winters and humid summers
in Ellenburg, which sits about six miles from the Canadian
border. Key to our plan was a ground-source electric heat
pump for space heating and cooling (see "Get Pumped"
sidebar). Producing the electricity needed to run our heat
pump — an estimated 7,400 kilowatt-hours per year — would
require substantial RE generation capacity. And while our
heat pump is also designed to assist in domestic water heating,
we'd still need to generate about 3,000 KWH annually for our
tank-style, backup electric water heater. Even though using
energy-efficient appliances and lighting would help keep the
remainder of our loads to a minimum, our annual electrical
load still came close to 17,000 KWH.
Because net-metering eligibility in New York limits the
size of residential PV systems to 10 KW, we planned to
add a 10 KW wind turbine to the 10 KW PV array. Based
on our site's solar and wind resources, this hybrid system
was projected to offset 100% of our home's energy use. Ice
storms can cause extended power failures in our area, so we
wanted a grid-tied PV system with battery backup, which
would supply electricity for the critical loads: an emergency
backup oil furnace, well pump, refrigerator, some lights, and
a microwave.
Working the System
Our plan was to install wind and PV systems prior to building
the house, and we didn't want to waste any time. Within
days of closing on the property, we contracted Sustainable
Energy Developments Inc. (SED) of Ontario, New York, to
install a 10 KW Bergey wind generator on a 120-foot tower.
But, in all the excitement, we overlooked a few critical details.
Apparently, our local power company. New York State
Even just the rotor assembly of the
10 KW Bergey is big and heavy.
home power 125 /June & july 2008
carbon free
Electric & Gas Corp. (NYSEG), was not very supportive of
on-site residential power generation. Even more sobering,
at that time, was that New York's residential net-metering
legislation for wind systems was not as favorable as it was for
PV systems. We would be credited only 4.2 cents per KWH
for excess energy our wind turbine produced but would have
to pay 17 cents per KWH for this "premium" electricity when
we needed to buy it back from the utility.
Another hurdle came when we discovered that the state's
property tax exemption for solar- and wind-electric systems
was voluntary, and that our local tax authority was one of the
few in the state that had opted out of the program. Based on
the full-retail value of our planned RE systems, the associated
property tax payment would amount to $3,000 per year. By
the numbers, our project made little economic sense. But we
weren't going to give up that easily.
We became frequent faces at city council and school board
meetings, grabbing anyone and everyone's ear whenever we
could to make our case for reversing the property tax policy.
For all our effort, we did persuade the local tax assessor to
add a new stipulation that the property taxes for each new
system would not exceed $227 per year — versus the $3,000
we had originally projected. Other good news was that the
New York state legislature was on board to approve a bill
that restructured the net-metering rules for wind energy.
According to these rules, which went into effect in 2006, we
would get full retail value for excess energy produced in any
given year, provided that the energy credits were used within
the same 12-month period. With the dollars-and-cents side of
things looking more promising, we decided to proceed with
our project.
Wrangling the Wind
Due to all of the regulatory hurdles, it wasn't until August
2005 that the Bergey wind generator was up and spinning.
The actual wind turbine installation went very smoothly.
SED did a fantastic job assembling the tower, turbine, and
balance of system components. However, we couldn't find
an appropriately sized crane within any reasonable distance
from the site to lift a pre-assembled tower. The resulting
section-by-section installation of the tower using rigging and
a gin pole turned out to be one of the highlights of the project
Get Pumped
The ground-source heat pump that heats and cools our
home — and supplements domestic water heating — is our
biggest load, consuming almost half of the electricity our RE
systems generate. This amount might sound high, but it's
actually quite low because of the high efficiency of the heat
pump and its ability to take advantage of ground temperature.
If we burned carbon-fuel (like oil or natural gas), the heating
load would account for 72% of our home's total energy
consumption.
Since our goal was to reduce our carbon footprint to zero,
fossil-fueled appliances were out. Electric resistance heating
would have been an option, but ground-source heat pumps
deliver heat with less energy input. A ground-source heat
pump takes advantage of the relatively constant temperature
below frost level in the ground — transferring ground heat to
the home in the winter and the home's heat to the ground
in the summer. These systems put out a lot more heat
energy than the amount of electric they consume (300%
plus), even on the coldest of winter nights. In our system, for
every 4.3 KWH of energy sent to the house, the compressor
consumes just 1 KWH for an overall efficiency of 330%. (For
more on heat pumps, see "Heat from the Earth — A Heat
Pump Primer" in HP98.)
Heat Exchanger:
Refrigerant to
potable water
and air
Compressor ( •
Heat Exchanger:
Groundwater to
refrigerant
~50°F
40°F
Source Well:
190 ft. deep
Dump Well:
220 ft. deep
for me.
Anyone with long-term experience with home-scale wind
systems will tell you that the technology isn't for the faint-
hearted, and my experience mirrors this seasoned perspective.
Compared to low-maintenance PV modules, which have
no moving parts and typically carry 25-year warranties,
wind turbines are inherently reliant on rotating parts that
are exposed to some of the harshest conditions imaginable.
Turbines have a tough job to do and, over time, can fail. While
our wind turbine installation went without a hitch, some
technical issues with the system still lay ahead.
Not all wind turbines, inverters, and their use together in
a given system will produce similar results when it comes to
producing energy. In our system, on days where wind speeds
www.homepower.corn
carbon free
tech specs
Overview
System type: Grid-tied, solar- and
wind-electric with battery backup
Location: Ellenburg, New York
Solar resource: 4.3 average daily
peak sun-hours
Average annual PV system
production: 10,400 AC KWH
Wind resource: 12 to 13 mph average
wind speed
Average annual wind system
production: 8,800 AC KWH
Utility electricity offset: 100% plus
PV System
Modules: 80, BP 3125, 125 W STC,
17.6 Vmp
Array: Five subarrays of 16 modules
each, four modules per series string,
70.4 Vmp, 10 KW STC total
Array installation: UniRac SolarMount
racks on south-facing roof, 45° tilt
Array combiner box: Five OutBack
PSPV with four 15 A breakers each
Batteries: 36 Rolls Surrette KS-21,
2 VDC nominal, 1,000 AH at 20-hour
rate, flooded lead-acid
Battery bank: Three series strings,
3,000 AH total at 24 VDC nominal
Charge controllers: Five OutBack
MX60, 60 A, MPPT, 70.4 Vmp input,
24 VDC nominal output
Inverters: Two Xantrex Series 2
SW4024 inverters with Grid Tie
Interfaces (GTIs), 4 KW each, 8 KW
total, 24 VDC nominal input, 120/240
VAC output
System performance metering: Two
form 12S AC KWH meters
Wind System
Turbine: Bergey Excel-S
Rotor diameter: 23 ft.
Rated energy output: 10,800 DC
KWH/month at 12 mph (5.4 m/s)
Tower: Bergey XLG37 guyed-lattice,
120 feet
Inverter: Xantrex GridTek 10, 10 KW,
batteryless grid-tie, 240 VAC output
System performance metering: AC
KWH meter
repeatedly exceed 28 mph, our Xantrex
GridTek 10 inverter spends much of its
time in standby mode. The turbine's
power output increases as blade speed
increases to 300 rpm — where the nominal
maximum output of 10 KW is produced.
In winds exceeding 28 mph, the turbine's
rpm continues to slowly increase. At
420 rpm (12.4 KW output), the inverter
goes into standby mode to protect it
from being overloaded. The inverter is
designed to stay in standby for five
minutes before turning on again. It will
attempt to go back online regardless of
how fast the blades are spinning.
But if the inverter tries to reconnect
when the turbine is spinning faster than
460 rpm, it goes offline and stays that way
until I notice it and do a manual reset. At
times, there may be hours or days of lost
production if I'm traveling or don't notice
that the inverter is offline. This issue
isn't unique to my unit: Testing at the
National Renewable Energy Laboratory
(NREL) documented this behavior back
in 2002. Because I only recently added
anemometers to the tower for measuring
wind speed, I can't yet be certain how
much energy production is lost due to
this issue, but I estimate between 8%
and 15%.
Considering what was to follow, the
inverter performance issue was minor.
In February 2006, the wind generator
threw a blade. This caused the turbine to
vibrate so violently that it broke the pivot
point connecting the turbine mount to the
tower and the turbine fell — my $23,000
wind generator was toast. Fortunately,
the 1,100-pound turbine did not hit any
guy wires on its way down — otherwise
it could have taken down the tower with
Mel and
Charleen with
the PV system's
component wall.
home power 125 /june & july 2008
carbon free
www.homepower.corn
carbon free
it A batch of defective blades was the cause of the failure. The
system sat idle for almost six months until we received a new
turbine in August 2006. The five-year warranty covered all the
costs, and Bergey generously compensated us for the value of
our lost electrical production — above and beyond the warranty
terms.
Harnessing the Sun
In the spring of 2005, while we waited for our replacement
wind turbine to arrive, construction of a new barn was
underway. The barn faces toward true south with 1,000 square
feet of roof area for our 10 KW PV array. We contracted
Vermont Solar Engineering to design and install a grid-tied
solar-electric system with about 60 KWH (at 80% depth of
discharge) of battery backup for critical loads. An array of 80
BP Solar 125-watt modules would feed five OutBack MX60
charge controllers. But before we got very far into the project,
we hit a few more regulatory stumbling blocks.
NYSEG rules did not allow both a wind and a PV net-
metered system on the same residential line. A call to NYSERDA
confirmed this, but they said they were in the process of
redrafting rules. NYSERDA contacted all power companies
in New York and found that Niagara Mohawk would allow
that combination. This gave the NYSERDA the leverage they
needed to rule that all New York power companies must follow
the policy allowed by Niagara Mohawk.
That good news came with caveats, though. Due to the
state's 10 KW cap on residential net-metered PV systems,
NYSEG would not approve the use of more than 10 KW of
rated inverter capacity. This restricted our inverter choices
and ultimately resulted in a less-than-optimal system. To
meet code, we ended up undersizing the inverter capacity
to 8 KW and selecting older-model Xantrex SW inverters.
It was a clear case of poor regulations dragging technology
down with them, as a variety of more efficient battery-based
inverters are currently on the market.
Setting aside the regulatory walls we hit, our PV system
has been operating without a serious glitch since November
2006. We were pleased with the job Vermont Solar did on our
installation, and they promptly corrected a couple of minor
problems.
Hitting Zero
At long last, the day came to break ground for our new home.
After nearly four years working through the regulatory and
technical issues related to the power systems, building the
house went surprisingly smooth, taking only about four
months. By January 2008, we were moved into our new two-
story home. The home features all the modern conveniences
and amenities, as well as low-E windows, low-toxicity
materials, and energy-efficient electric appliances.
Although the up-front costs of our home's energy systems
tacked on an extra 40% to the cost, the investment was well
worth it. NYSERDA provided a 50% rebate on the installed
cost of both systems, and we were able to take advantage of
state and federal tax credits, which lowered our initial system
costs significantly. In the long run, as utility rates continue
to climb, the cost to operate the home will be far less than a
conventional home that depends on fossil fuels. Over the past
nine years, the price of electrical energy has been increasing
at 3.7% annually and fuel oil has increased 14.6% per year.
Taking this into account. I've calculated that our initial return
on investment is about 5.4% per year and increases each year
as the projected cost of energy goes up. This results in an
estimated financial payback period of 10 to 11 years.
While there were definitely some frustrating phases during
the project, our solar-electric and wind systems have been
operating smoothly for more than a year. I'm proud to say that
we've reached an actual production of 19,000 KWH, and are
offsetting more than 100% of the energy required to heat, cool,
and power our new home, without relying on any fossil fuels
or wood. Despite the problems, I wouldn't hesitate to tackle
the project again.
Access
Mel Tyree (Mel.Tyree@ales.ualberta.ca) is a university professor who
likes to build scientific equipment and tinker with electronics. As a
public service, he compiles and posts information about small wind
turbines on a University of Alberta Web page, called the Small Wind
Information Exchange Program (www.ualberta.ca/~mtyree/SWIEP).
Sustainable Energy Developments Inc. • 585-265-2384 •
www.sed-net.com • Wind power equipment and installation
Vermont Solar LLC • 800-286-1252 • www.vermontsolar.com •
Solar-electric equipment and installation
Small Wind Info:
AWEA Small Wind Listserve • www.groups.yahoo.com/group/awea-
smallwind/
SWIEP • www.ualberta.ca/~mtyree/SWIEP or http://tech. groups.
yahoo.com/group/SWIEP • Consumer reporting group on wind
systems
System Components:
Bergey • www.bergey.com • Wind turbine
BP Solar • www.bpsolar.com • PV modules
OutBack Power Systems • www.outbackpower.com •
Charge controllers
Surrette • www.surrette.com • Batteries
UniRac • www.unirac.com • PV mounts
Xantrex Technology Inc. • www.xantrex.com • Inverters
home power 125 /june & july 2008
Apricus Solar Hot Water Systems
Perfect For
V' Residential hot water
Space heating
S Hot tub heating
V" Commercial heating
The brightest way to capture the sun
Distribution
partners and
installers still
needed in many
*>
regions.
■B
The Apricus Advantage
V Proven Designs
S Long Warranty
V' Customer Service
S Reliability
S Performance
V Quality Installation
North America Toll-free: 877-458-2634
Visit: www.apricus.com
POWER. DURABILITY. PERFORMANCE ,
Depend on the Power of Maroon for your most
demanding off-grid and grid-tie backup applications:
• Building the most trusted deep cycle flooded batteries in the world since 1 925
•The next generation of Deep-Cycle Gel™ and AGM batteries for maintenance free
cycling and backup applications
Our signature deep cycle construction and durable Polyon™ casing are available through
Trojan Battery's worldwide distribution network.
Visit our booth #609 at SOLAR 2008
May 3-8, 2008, San Diego, CA
Trojan,
BATTERY COMPANY#
Clean energy for life m
For live technical support, call 800-423-6569 or visit us at www.trojanbattery.com.
Harvest the
f£r of
Season after season,
the sun gives its light to the earth,
allowing life to bloom.
Every day a limitless crop of free,
clean energy reaches our planet.
Stiebel Eltron manufactures all the tools you
need for a successful thermal solar harvest.
And we've been doing so since 1976.
From our highly efficient flat plate collectors and
storage tanks to our complete line of mounting
hardware, pump stations, controllers, and
accessories, we have it all.
Stiebel Eltron is your one stop solar shop.
SOLKIT 2 includes:
2 x SOL 25 PLUS
Flat Plate Collectors
Pump station with
SOM 6 Controller
SBB 300 Plus Storage Tank
Because every installation is
different, we have a full line of
SOLKITS and mounting
hardware kits available. All
components and accessories are
available for individual sale.
Stiebel Eltron is the
authorized distributor
of Thermomax®
vacuum tube collectors
for New England.
S TIEBEL ELTRON
Simply the Best
800 - 582-8423
17 West Street
West Hatfield, MA 01088
info@stiebel-eltron-usa.com
www.stiebel-eltron-usa.com
Hydro-Electric Penstock Design
by Jerry Ostermeier
If you want to extract every last bit of energy from your
microhydro system, three main components are critical
to optimal performance — intakes, penstocks, and turbine
selection. Intake options were covered in HP124, along with
various methods of diverting water from the source. Here,
we'll talk about best practices for penstocks, which channel
the water from the intake to the microhydro turbine, building
up pressure along the way.
In many ways, the penstock (pipeline) is the most
important part of your hydro-electric installation. It's the
"engine" in your system. Trying to cut corners on this design
element can cost you in performance. And poorly installed
penstocks can give you trouble, instead of what you're really
after — maximum energy generation.
Pipe Types & Pressure Ratings
Almost any type of pipe will work as a penstock, at least to
some degree. The most common types are white polyvinyl
chloride (PVC) and "poly pipe" (black polyethylene, PE; or
high-density polyethylene, HDPE), which come in several
pressure ratings. Common drainpipe is thin- walled and not
rated for pressure. Though it can accommodate up to about
30 feet of head if you are careful opening and closing valves,
drainpipe is not normally a recommended choice.
Intake and top section of penstock with standpipe vent.
Standpipe
or Vacuum Release Valve
Weir & Intake:
See HP124
The rules are simple
straight as possible, round sweeps,
and steady elevation declines.
Supports:
Keep pipe run
smooth over
varied terrain
home power 125 /june & july 2008
hydro penstock
In selecting pipe with the correct pressure rating, be sure
to allow an extra 40% above the static water pressure in the
pipe. For example, with 200 feet of head, the static pressure
is about 87 pounds per square inch (psi). Multiply that by 1.4
(140%) to reach the needed pipe pressure rating of 122 psi.
To compute the static pressure for the proposed penstock (in
psi), divide the total head (in feet) by 2.3.
To save on penstock costs, a system can use pipes of
increasingly higher pressure ratings as it gets closer to the
bottom of the run, where pressure is highest. In that case,
calculate the pipe pressure ratings for different total heads as
you move down the pipeline.
Some hydro installers will disagree, but my strong
preference for penstocks is to use PVC pipe in 20-foot lengths
with a bell end for gluing lengths together. Splices used
for other pipe types are not reliable at high pressure or for
unrestrained pipe movement. Thin-wall poly pipe comes in
a long roll and can be easy to use, especially if your penstock
has to weave through trees and over rocks to the turbine, and
if you can complete the entire run without splices. Thick-wall
poly pipe requires special butt-welding equipment. The welds
will leave a bead on the inside of the pipe that will affect flow.
In our area, the critters tend to like chewing on poly pipe, but
in other parts of the country, they seem to have a taste for the
white PVC.
Aluminum pipe can be easy to get in agricultural areas
but generally should only be used for pressures up to about
125 psi. It should not be buried unless treated to deal with
the acidity in soils. Steel will handle very high pressure but
should also not be buried, since it will rust out over time.
Common PE poly pipe and HDPE have pressure ratings
around 80 psi. They are available at even higher pressure
ratings but can be hard to get in larger sizes.
Dealing with Losses
Aluminum, steel, and poly pipe have comparatively high
friction loss (resistance to flow), so it is important to factor this
loss into sizing — which can play a part in system cost. As with
different types of electrical wire, every pipe type has different
resistance to flow based on the roughness of the walls. Also
like wire, the diameter of the pipe determines the resistance
to flow and how much flow the penstock can handle. In
very high-head situations, steel pipe might be the only pipe
capable of handling the high pressures.
Pipe friction-loss tables for each pipe material will tell
you how much flow a particular pipe size can handle. Then,
by comparing prices, you can determine if changing pipe
Round
the
Bad: 90° elbow;
lots of friction loss
Good: Multiple 22.5°
sweeps; far less
friction loss
Pipe lengths: At least
three times pipe
diameter
diameter or material type is worthwhile. Steel and aluminum
pipes generally have double or more the resistance of PVC,
and the larger sizes tend to make it prohibitively expensive
for use in small systems.
Friction-loss tables are commonly used for hydro penstock
sizing (visit www.homepower.com/penstocktables), but
precise friction-loss calculations can become complicated
because they deal with velocity, pressure rise, critical time,
and pressure wave velocity — frankly, it can become a physics
exercise. But more simplified pipe sizing " rules" can address
all the factors adequately. The following rules are for typical
PVC schedule-40 pipe with runs of 300 to 1,200 feet. Short,
Choose your pipe type based on head,
flow, run length, and your budget.
hydro penstock
straight pipe runs can exceed these max flow rates a little —
longer pipe runs need to be reduced.
• Up to 7 gpm can use 1-in. pipe (300 ft. of static head or
higher)
• Up to 15 gpm can use 1.25-in. pipe (250 ft. of static head or
higher)
• Up to 25 gpm can use 1.5-in. pipe (200 ft. of static head or
higher)
• Up to 45 gpm can use 2-in. pipe (any head)
• Up to 75 gpm can use 2.5-in. pipe (any head)
• Up to 110 gpm can use 3-in. pipe (any head)
• Up to 190 gpm can use 4-in. pipe (any head)
• Up to 300 gpm can use 5-in. pipe (any head)
• Up to 430 gpm can use 6-in. pipe (any head)
The "rules" list is based on rounded estimates. If you are
pushing the envelope within a pipe size, it is usually better to
go bigger. This strategy will almost always improve system
performance. The same holds true for long pipe runs. Bigger
pipe will make more power available to your hydro plant at
the bottom end of the penstock.
Web Link: For more information on determining
pipe and fitting friction loss, go to www.homepower.
com/penstocktables
Penstock Protection
Poly pipe is well known for being chewed on by rats,
raccoons, and bear, to name just a few — but PVC has been
attacked too. On the other hand, poly pipe can sometimes be
better than harder-shelled pipe types because it is relatively
freeze-tolerant and can be a little tougher for laying over
treacherous terrain. Buried pipe offers more protection from
toothsome critters, freezing, and falling trees, and more
stability to handle pipeline movement.
If you are burying the penstock, the recommended trench
depth is 2 feet for pipe up to 4 inches in diameter. Bury larger
pipe at least 2.5 to 3 feet deep. Also be sure to check average
frost depth in your area. Although moving water generally
won't freeze in most climates, snafus — such as blocked
nozzles in the turbine — can stop the flow of water and lead to
freezing during a cold snap.
The trench bed should be free of sharp rocks that can
damage the pipe. A layer of sand or pea gravel under the
pipe works great. The trench should not curve beyond the
Supporting the penstock with brackets and cables helps
keep the run smooth and prevents pipe movement.
home power 125 /june & july 2008
hydro penstock
Valves St Vents: Microhydro Relief
Placing a valve between the intake's pipe and the main penstock
can be quite handy when you need to shut down a hydro system
for maintenance or freezing weather. Any type of valve, other
than a plastic slide-gate, will work. I usually place a union close-
coupled just below the gate valve, so I can clear pebbles or other
debris that might accumulate in the cavity at the bottom of the
valve and prevent the valve from closing completely.
Sometimes, instead of adding a valve, the connector between
the penstock and the intake pipe, such as a rubber compression
union, can be removed to keep water out of a penstock. This is
not only a hassle and slower than a valve but also problematic
if the pipeline has to be shut down in a hurry. Some systems
may use a rubber hose to connect the two pipes. In this case, it
is important to make sure that the hose is suction-rated and has
wire coil molded into the rubber to prevent collapse. A screw-
apart union or a compression splice can also work to keep water
out of the penstock.
At the turbine, consider using a gate valve for the main shutoff —
especially for high-head systems. Compared to a ball valve, they
operate slower, reducing the risk of water hammer — an effect
caused by stopping a flow of water too quickly. There's a lot
of kinetic energy in water flowing down a pipe, and gradually
slowing the flow to a stop will avoid the high pressures that can
break or weaken a pipe and its joints. A ball or vane valve can be
a better choice on lower-head applications because they create
less turbulence at their typically higher-flow rates. Regardless of
your system type, this rule is paramount: Be careful to shut the
main valve at the turbine slowly to avoid water hammer.
Venting also should be included in any design, especially in
a system that has an upper shutoff valve, because there is a
chance that the intake screen could become blocked enough to
collapse the penstock. The down-pipe movement of water can
create tremendous suction in the pipe if its flow is stopped from
above. At 200 feet of head, a pipe has greater risk of collapsing
from suction than breaking from water hammer when a turbine
shutoff valve is suddenly closed.
A manual valve works as an air-vacuum release.
Top-of-penstock components.
The diagram above shows an automatic air-vacuum-operated
release valve. If a vacuum occurs, the valve lets the penstock
drain without damage. Penstocks 4 inches and smaller should
use a V 2 -inch or larger valve. Larger pipe should have a valve
sized no less than one-sixteenth the diameter of the penstock.
Another method for suction relief uses a standpipe, which must
be placed below the valve to the penstock and extend above the
maximum level of the water source at the diversion. This keeps
the penstock open to the atmosphere above the water level. Be
sure to place the standpipe far enough down the penstock so that
the system will have enough suction to draw through the intake
instead of sucking air down the standpipe.
A standpipe can also help purge from the penstock any air
bubbles mixed in with the water that result from turbulence
in the intake area. Spring-loaded and manual vents are also
available. Avoid the floating ball type because they tend to open
when they shouldn't, sucking air at higher-flow rates or in the
event of partially obstructed intake filters. Air trapped at any
high points in the pipeline can slow or stop water, decreasing or
even stopping turbine output. At low heads (32 feet or less), this
is not usually a problem, but air in the penstock can also lead
to premature bearing failure in the turbine, or even damage the
runner, when an on-off repeated pulse set up by water-airspace
repetitions acts like little hammer blows hitting the runner. The
higher the head and the bigger the airspace, the greater the blow
to the turbine.
Another air-removal method is to use permanently installed
manual valves to bleed the air from the high spots when the
penstock is full but not flowing. Some hydro system owners will
simply thread a screw into the penstock at the high points, and
occasionally back the screw out to bleed any accumulated air.
The bottom of the system should always include a drain valve for
draining all piping or bypassing the hydro plant. In cold climates,
the unburied end of the penstock, valves, and hydro manifold
are susceptible to freeze damage if the flow is stopped, so it is
critical to keep the drains or bypass open if freezing weather is
imminent. This applies to all nozzles on the hydro — not just the
ones that are currently "on." Re-jet the nozzles if necessary to be
able to open them all. If you can't, it is better to shut the whole
thing down and drain everything. Not paying attention to this can
cost you several hundred dollars in freeze damage.
www.homepower.corn
hydro penstock
A penstock, heavy with water, should be anchored at the
turbine to keep from moving downhill. How much anchoring
is necessary is calculated in the same manner as any other thrust
blocking. In areas with very steep terrain, there may be no way to
apply thrust blocking in the normal manner. Instead, the pipe can
be anchored with wire rope by attaching one end to the hillside's
rocks or trees and the other end to the pipe, and then, using
tumbuckles for adjustment.
Lower Penstock & Hydro Connection
Connecting the turbine to the penstock usually involves
correcting the angle of the downhill pipe run to match the
turbine's angle, which is usually zero. You can change the
angle with a king nipple (similar to a hose barb) and a short,
high-pressure piece of rubber hose, or you can use two
22.5-degree elbows that can make any correction up to 45
degrees. Correction may be unnecessary for hydro turbines
that have a gang manifold at the end of the penstock or
use valves and hoses to feed the individual nozzles. Some
manifolds are hard-plumbed, and will likely need an angle
correction where they meet the penstock. A cleanout valve at
the end of the manifold may also be helpful for draining or
flushing leaves and trapped sediment.
The most visually impressive installations have the pipe
exiting the ground at a 22.5-degree or 45-degree angle inside
a shed or protected area that houses the hydro turbine. If you
keep your turbine out of the weather, it will last longer and
need less service, especially the wound-field models.
Hydro Mounting & Tail Race
Since most turbines are meant to discharge water out the
bottom, it's important to design your system so the "waste"
water can move away freely. In constructing a turbine mount,
be sure that the cutout is not smaller than the turbine's tail-
water opening. A cutout that is too small will deflect water
back into the runner and reduce the system's performance.
At the Turbine
recommendations for the particular pipe being laid in it, or else
the pipe could break or distort to the point of flow restriction.
Water weight and normal vibrations from water moving
through the pipe can cause the pipes to move. Where a
change in flow direction occurs, like at an elbow, powerful
forces can break or separate connections. "Thrust blocking"
at the bends in the system prevents that pipe movement.
Blocking is usually unnecessary for 3-inch or smaller pipe
that is buried in most soils. The illustration above shows
recommended thrust blocks for different bends commonly
found in penstocks. For pipes up to 5 inches, it is prudent
to dig a little deeper at the critical points, build a makeshift
form, and pour concrete over the entire corner. Though the
concrete does a good job at keeping the pipe in place, it also
can make pipe replacement or repairs difficult later on. For
larger pipe and high-flow situations, the size of the thrust
block must be calculated precisely, (see "Calculating Thrust-
Block Size" sidebar).
From Penstock
home power 125 /June & july 2008
hydro penstock
Calculating Thrust-Block Size
Preventing pipe thrust from harming a penstock is critical to
a successful hydro installation. Here is a sample thrust-block
design calculation for a 45-degree bend in the penstock. This
case assumes that a 4-inch pipe under 87 psi of pressure is
buried in medium, clay-type soil.
Determine pipeline thrust. From the "Pipe Fitting Thrust" table,
the factor is 12.4 Ibs./psi for a 4-inch pipe and a 45° elbow.
Calculate the total thrust at the fitting. 12.4 Ibs./psi x 87 psi
working pressure = 1,078.8 lbs. of thrust
Determine soil load strength. From the "Soil Load Strength"
table, the soil load strength is 2,000 lbs. per sq. ft.
Calculate the size of the thrust block. 1,078.8 lbs. 2,000 lbs.
per sq. ft. = 0.54 sq. ft. of thrust-block surface area
The computation means that 0.54 square feet of blocking is
necessary to hold the bend against the medium clay-type soil.
Concrete is usually poured over the pipe fitting, filling the area
against the undisturbed trench sides for thrust blocking.
For unburied pipe or pipe in soft soils with little resistance to
movement, thrust blocking needs to rely on mass instead of the
area resting against trench wall. Here is an example calculation
of thrust block weight for a 6-inch pipe at 139 psi with 8 degrees
of deflection:
Determine the thrust factor. From the "Side Thrust" table,
6-inch pipe has 61 lbs. of thrust per 100 psi per degree of
deflection.
Calculate the amount of thrust. 0.61 Ibs./psi x 8° x 139 psi = 678 lbs.
This means that there needs to be 678 pounds of mass (usually
poured concrete) to keep this penstock from moving at the
bend.
A chunk of concrete, cast in place, acts as a thrust block for a
small change in direction of this penstock.
Pipe Fitting Thrust
Thrust (Lbs./psi)
Pipe
Size (In.)
Tee
90°
Elbow
45°
Elbow
22.5°
Elbow
1.5
2.94
4.16
2.25
1.15
2.0
4.56
6.45
3.50
1.80
2.5
6.65
9.40
5.10
2.60
3.0
9.80
13.90
7.50
3.80
4.0
16.20
23.00
12.40
6.30
5.0
24.70
35.00
19.00
9.70
6.0
35.00
49.00
27.00
14.00
8.0
59.00
84.00
45.00
23.00
10.0
92.00
130.00
70.00
36.00
12.0
129.00
182.00
99.00
50.00
Soil Load Strength
Soil Type
Safe Bearing Load (Lbs./Sq. Ft.)
Shale
10,000
Cemented sand & gravel;
4,000
hard to pick
Good mix compact soil
3,000
Clay — medium
2,000
Clay — soft
1,000
Side Thrust
Pipe Size (In.)
Thrust Factor*
1.5
5
2.0
8
2.5
12
3.0
17
4.0
28
5.0
43
6.0
61
8.0
103
10.0
160
12.0
225
*Lbs. per 100 psi per degree deflection
Although the most common mount is a simple, 2- by 4-foot
plywood, structure, built close to the water source, the most
durable mounting platforms are sturdy plates on permanent
concrete structures with the tail or waste water exiting the
bottom or side, either into a wide opening or a drain pipe. The
drainpipe needs to be at least twice the diameter of the supply
pipe, with a reasonably steep downward slope. An air vent in
the tailbox will help prevent the tail water from sucking on
the water running through the hydro, creating a power loss
on an impulse turbine. The vent also removes pressure so that
water won't find its way into the front bearing, which can
lead to a bearing failure in some hydro turbines.
www.homepower.corn
61
Courtesy www.microhydropower.com
hydro penstock
Another popular hydro mounting method uses a modified
55-gallon metal drum, with the turbine fastened to the drum
top with bolts. The bottom third of the drum is secured into
the creek bank with concrete or by loading the drum with
rocks. The middle third has a hole drilled out, which allows
water discharge. These drums will usually last about 10 to 15
years before they rust out.
Alternatively, an up-ended culvert pipe that is 24 inches
or larger can be used, though fabricating a top will be more
difficult. My preferred top is a high-density polyethylene
sheet at least V2-inch thick. This special-order item is more
expensive, yet longer lasting, than plywood.
Mounts can have more elaborate masonry spillways or
even drains that feed to a decorative water feature in the
yard. Other times, the tail water can be used for a secondary
purpose, such as filling a pond or irrigating a garden. Let
your imagination be your guide, but remember that once you
have extracted the energy for making electricity, the water
will not be pressurized for other uses and gravity needs to
take the water away freely.
The final consideration for hydro mounting is protection
for electrical portions of the control panel. Though rain
needs to be kept out, the unit should not be so well sealed
that condensation becomes a problem. A roofed, three-
walled structure for the turbine works great. One side is
left open for easy access to the hydro plant. Although most
permanent-magnet turbines are built for outdoor operation,
they will last longer if protected from the elements. In terms
of human resilience — an all-important factor to enable turbine
maintenance — having a shelter makes repairs, flushing the
penstock, and cleaning the turbine jets much more tolerable.
The components at the bottom: Thrust block, coupler, pressure
gauge, cleanout valve, nozzle valves, turbine, and tailrace.
Tailrace Hole:
Cut from middle
section
Ballast:
Rocks in bottom
55-Gallon Drum
Best Penstock Practices
For penstocks, the rules are simple — straight-as-possible,
round sweeps, and steady elevation declines. Unfortunately,
that's usually easier said than done. Often times, site constraints
make it necessary to break or bend the rules. You should do
what you have to do, but know that your system will be more
vulnerable to performance and maintenance issues. Any low
spots in the pipeline, for example, could become sediment
traps that will occasionally need to be blown out by opening
the pipe at the bottom and letting it run full volume. High
spots in the penstock will create air pockets that will need to
be bled. Finally, any bend in the pipeline will mean greater
resistance to flow and reduce the energy available.
Include a pressure gauge in the pipe on the uphill side of
the lower shutoff valve to help diagnose problems. A higher-
than-normal reading usually indicates a plugged jet. A lower-
than-normal reading can mean that the pipe or filter screen
is plugged, or that there is not enough water available to the
penstock. A pulsating gauge indicates turbulence, usually
caused by running a higher flow rate than the penstock is
designed for, which can result from installation errors, such
as too many bends or an uphill run somewhere.
Select the right pipe, anchor it well, and keep it straight
and simple. Follow these rules, and the penstock "engine"
will serve you and your turbine well — and get the most
energy out of your hydro system. And be sure to check out
the next installment, where we'll take a look at the electrical
and wiring aspects of your hydro system.
Access
Jerry Ostermeier (altpower@grantspass.com) owns Alternative
Power & Machine in Grants Pass, Oregon (541-476-8916 • www.
apmhydro.com). He has been designing and installing microhydro
and off-grid power systems since 1979. He also manufactures a user-
friendly residential-scale microhydro turbine.
home power 125 /june & july 2008
We DESIGN, MANUFACTURE and DELIVER the
sun’s unlimited energy to your everyday life
We are an internationally recognized manufacturer of high quality mono
and multicrystalline PV modules with locations around the globe. We are
one of the few PV manufacturers that has developed a vertically integrated
business model from the production of crystalline ingots, wafers and cells to
the assembly of high quality modules. Producing each step of the value
chain in-house helps to ensure that we deliver high quality products to our
customers for clean and efficient residential, commercial and utility-scale
solar solutions.
TRINA SOLAR. CELEBRATING TEN YEARS OF SUCCESS IN SOLAR, THANKS TO YOU!
Visit us: InterSolar North America, San Francisco, CA, July 15-17, 2008 (Booth #: 9112)
Trmasolar
www.trinasolar.com
usa@trinasolar.com
NYSE:TSL
A
B
A «
www.homepower.com
rebuilt & fully loaded for 2008
F or more than twenty years, Home Power magazine has inspired and
educated readers with practical, reliable information about renewable
energy and sustainable living technologies. Homepower.com now enables
you to conveniently browse, download, and print the best of that content
online, anytime, for just $24.95 (one year).
Membership to homepower.com includes:
► Access to a growing pool of more than 1,300 feature articles, columns, Q&As, and more
► Advanced search and filtering functionality to quickly find what you’re looking for
► Access to three years of complete back issues in PDF, exactly as published
► E-mail notification when each new issue of Home Power is available for you to download
► The option to add a subscription to Home Power’s print edition for just $9.95 per year!
Already a subscriber to the print edition of Home Power ?
Add an online membership for just $9.95 per year.
Visit homepower.com to explore what’s new and activate your membership today:
www, homepower, com / j om
DC Power\
Systems^
Proud Distributor of Sharp Solar Energy Products
fr
£
!!-;
to
m
V ! 1
A? J
Vi Jr 1
'it:: \
sen
in
Efl j
Sharp Solar Racking System (SRS):
• Integrated grounding • Shared rail design
• No protruding screws • Ultra low profile
• No cutting, no drilling • Covered rails
• Fast, simple installation • Economical
To order the new Sharp SRS System
call us at 800-967-6917
DC Power Systems
Full spectrum of solar energy products, in-house tech support, product training,
financing solutions and unparalleled product availability
Become a DC Power Systems dealer today
103 W. North St. Healdsburg, CA 95448 phone 800-967-6917 fax 707-433-5698
info@dcpower-systems.com www.dcpower-systems.com
String Theory
PV Array
Voltage Calculations
by Ryan Mayfield
A decade or so ago, most PVs were designed with
battery charging in mind. Module open-circuit and
maximum power voltages fit into simple 12- volt
nominal building blocks — one or more modules wired in
parallel provided ideal voltage for charging a 12 V battery
bank. Strings of two modules wired in series charged 24 V
battery banks, and "high" voltage systems had four modules
in series and operated at 48 V nominal. But as inverter
and charge controller designs have evolved, the concept of
designing systems in 12 V increments has faded.
Today, grid-direct battery less inverters are designed for
up to 600 volts open circuit (Voc). Several brands of maximum
power point tracking (MPPT) charge controllers are able to
charge a lower-voltage battery bank (12 to 48 V nominal)
from higher-voltage arrays with open-circuit voltages of
approximately 150 Voc. Even module design voltages have
The Fronius IG 5100
inverter has an
operating voltage
range between 150
and 450 VDC, and
a maximum input
voltage of 500 Voc.
The Fronius string-
sizing calculator
is available
online and for
downloading.
deviated from the simple 12 V building-block approach. First,
24 V nominal modules hit the market, and now many modules
operate at voltages either above or below 24 VDC nominal. In
fact, in most systems, the concept of PV array nominal voltage
has been left by the wayside. Open-circuit voltage (Voc) and
maximum power voltage (Vmp) are now the basis of PV array
design.
home power 125 /June & july 2008
String Sizing Considerations
A number of variables affect PV array
voltage and performance. Module-
specific operating characteristics, the
number of modules in series, cell
temperature, mount type, inverter or
charge controller specifications, and
the coldest historical temperature at
your site all come into play. Most,
if not all, high-voltage-string inverter
manufacturers have online calculators
to help system designers determine
the maximum, minimum, and the ideal
number of modules per series string
for their equipment. Similar calculators
have yet to be developed by all MPPT
charge controller manufacturers, so
system designers need to run their
own calculations to determine an
array's acceptable voltage range.
While string-sizing calculators remove
much of the math from system design,
understanding how the calculations are
made will help you better understand
how a PV array functions day to day
and season to season.
string theory
IV Curve per Cell Temperature
HighTemp. (63°C; 145°F) STC (25°C; 77°F) Low Temp. (-22°C; -8°F)
Temperature Effects & Array Voltage
A PV module's voltage is directly affected by its operating
temperature. As module temperature increases, voltage
decreases. PV module manufacturers rate a module's open-
circuit and maximum power voltages at a standard test
condition (STC) of 25°C (about 77° F). As module temperature
rises above 25°C, the voltage drops. Conversely, if the
module's temperature drops below 25°C, the module's
operating voltage will be greater than its rating at STC.
Because temperature has a significant effect on module
output, PV manufacturers specify a module's temperature
coefficient, which is represented as a percentage of voltage
loss per 1°C above 25°C. A common temperature coefficient
value for crystalline PV modules is -0.38% per degree Celsius;
so for every 1°C above 25°C, the module temporarily loses
0.38% of its voltage. And for every 1°C below 25°C, the
module voltage will increase by 0.38%.
Another approach to specifying the effect of changing
module temperature is a voltage correction value — the
number of volts per degree Celsius that the module will
lose as its temperature rises above the 25°C reference point.
For example, a crystalline module with a maximum power
voltage of 34.8 volts might have a temperature correction
factor of approximately -0.144 Voc per degree Celsius. These
figures are provided on the module's specification sheets.
The Kaco 3601xi
inverter has an
operating voltage
range between 125
and 300 VDC, and
a maximum input
voltage of 400 Voc.
The Kaco string-
sizing calculator
is one part of the
system design
software available
for download.
www. homepower . com
string theory
It may not sound like much, but when the temperature
values are applied, the combined effect can be substantial.
For example, on a sunny summer day, module temperatures
in a parallel-to-the-roof array installation will typically be
about 35°C (63°F) above ambient temperature. If the module's
temperature coefficient was -0.38%, for every degree Celsius
in temperature rise array voltage will be reduced by this
percentage. In this case, if the ambient temperature was 25°C
(77° F), the module temperature would be approximately 60°C
(140°F), and the actual array voltage would be about 13.3%
below its rated value at STC.
Sizing to the Voltage Window
The power processing equipment connected to a PV array also
has an allowable voltage range. This is true of high-voltage
string inverters, battery-based MPPT charge controllers, and,
less commonly, DC loads, such as well pumps that are
directly connected to PV modules.
The SMA online
string-sizing
calculator.
The SMA Sunny Boy
SB7000US inverter
has an operating
voltage range
between 250 and
480 VDC, and a
maximum input
voltage of 600 Voc.
These components have both maximum Voc and minimum
Vmp requirements. Together, these specifications represent the
"voltage window" within which the components can operate.
For example, a high-voltage grid-direct inverter might have a
maximum Voc rating of 600 volts, and an operating voltage
range or window between 240 and 550 VDC.
In many cases, inverters and charge controllers can be
damaged if the array produces voltage greater than the
maximum value of the equipment, which can happen in
cold, sunny weather if the design voltage is too close to the
maximum. In turn, if the array voltage drops below the
minimum value due to elevated temperatures, inverter or
controller power production will stop until the array cools and
the voltage rises. Because of this, PV system designers need to
account for both extremes of the voltage window to ensure that
the PV system will perform in the full range of conditions.
For a particular piece of equipment, voltage correction
factors must be applied to the array's assumed operating
temperatures for the system's site. This information is one
piece of the puzzle that will help determine the appropriate
number of modules allowed in a series string.
It all boils down to choosing a string size that meets three
very important parameters while trying to optimize a few
more. You must satisfy a voltage window that, on the high
end, is limited by the maximum open-circuit voltage that
the inverter or controller can handle before you harm its
electronics. On the low end, there are two limiting factors —
the minimum MPPT voltage that the inverter can operate
at and the minimum start-up voltage the inverter needs to
have. If the maximum Voc and minimum Vmp values are
correctly calculated and the array designed to these specs, the
minimum start-up voltage will always be met.
Once you have satisfied these requirements, you'll still need
to determine the appropriate array wattage to ensure you are
home power 125 /june & july 2008
string theory
using the inverter or controller efficiently. Oversizing an array's
wattage typically won't damage inverters or controllers, but a
portion of the array's output will be dumped (wasted) as heat,
and elevated operating temperatures may lead to shortening
the operational life of the equipment. When sizing the array,
you'll also have to stay within the inverter or controller's
amperage limit, and size transmission wiring to keep voltage
drop to a minimum. Finally, because PV module output is
inherently temperature dependent, all of these parameters
are moving targets, with cold and hot weather performance
varying greatly, and array output current changing throughout
the day as irradiance levels fluctuate.
Maximum Modules in Series
PV modules reach open-circuit voltage with very little irradiance
striking them, approximately 200 watts per square meter. This
can often occur within half an hour of sunrise, before the sun
has the opportunity to warm the modules. And although the
array will be at Voc and not producing any power, that voltage
will be applied to whatever component it is connected to.
To determine the maximum number of modules allowable
in series for a given piece of equipment, you'll need to
determine array Voc at the coldest historical temperature
where the array will be installed (see www.weather.com/
common /home/ climatology.html). You may need to adjust
this value somewhat for your microclimate and elevation.
The temperature used in this calculation is most often the
record low temperature at the array location. To determine
the adjusted open-circuit voltage (Vadj) for the PV module,
use the following equation:
Vadj = Voc x {1 + [(Tcell - Tstc) x temperature coefficient]}
Where:
Vadj is the adjusted voltage for the module;
Voc is the STC open-circuit value for the module;
Tcell is the module's cell temperature in degrees Celsius
(the cell temperature in this situation will be the same as
the coldest historical ambient temperature at the site);
Tstc is the STC temperature value for the module,
generally 25 °C; and
Temperature coefficient is the percentage loss of voltage
specified for the module.
To determine the maximum number of modules allowed
for a piece of equipment, the adjusted voltage must be divided
into the equipment's given maximum voltage (Vmax). Round
down to the next whole number to ensure the array's voltage
will not exceed the maximum value.
Minimum Modules Needed Per String
After calculating the maximum number of modules allowable
per string, verify the minimum number of modules needed. The
array needs to be sized so that when the system is operating at
high temperatures, the array voltage remains above the minimum
voltage-window threshold to ensure continued operation. To do
this, you'll need to determine the array voltage (Vmp) based on its
typical operating temperature during the hot summer months.
Example String-Sizing
Calculations
Location & Climate
Location: Corvallis, OR
Record low: -22°C (-7°F)
Average low: 1°C (34°F)
Average high: 28°C (82°F)
Record high: 42°C (108°F)
Photovoltaics
Module: SolarWorld 175 W
Voc: 44.4 V
Vmp: 35.8 V
Temperature coefficient: -0.33%/°C
Mount type: Parallel-to-roof mount
(4 in. from roof surface to back of module)
Equipment
Inverter: PV Powered 5200
Maximum Voc: 500 VDC
Minimum Vmp: 240 VDC
Calculations
Step 1. Calculate the adjusted voltage for low
temperatures.
Vadj = 44.4 V x {1 + [(-22°C - 25°C) x -0.33%/°C]}
Vadj = 51.3 V
Determine the maximum number of these modules in
series for this inverter at this location:
Maximum number per string:
Component's max. Voc Vadj for low temperatures
500 VDC - 51.3 V = 9.7 modules
Round down to the next whole number — in this case,
nine modules is the maximum number in series.
Step 2. Calculate the adjusted voltage for high
temperatures.
Vadj = 35.8 V x {1 + [(28°C + 35°C - 25°C) x -0.33%/°C]}
(Note the additional temperature — 35°C — due to the
racking method.)
Vadj = 31.3 V
Determine the minimum number of these modules in
series for this inverter at this location:
Minimum number per string:
Component's min. Vmp Vadj for high temperatures
240 VDC -r 31.3 V = 7.7
Round up to the next whole number — in this case,
eight modules is the minimum number in series.
Comparing these calculations to those for other equipment
will determine if you may be better off with a different
combination of equipment. The minimum value calculated
should always be carefully considered and is rarely the
best choice. In this example, if strings of eight modules
are used, the resulting Vmp on an average day will only
be 250.4 — precariously close to the low value (240 VDC) of
the sample inverter's operating window.
www.homepower.corn
string theory
The Xantrex GT5.0
inverter has an
operating voltage
range between 240
and 550 VDC, and
a maximum input
voltage of 600 Voc.
The Xantrex
online string-
sizing calculator.
Hacking Correction Figures
Two things — array mounts and operating temperatures — are
important in evaluating the array's operating voltage. The type
of module mounting used influences heat dissipation — some
methods allow for better airflow than others (see "Rack &
Stack" in HP123). And although there are methods to estimate
the module's operating temperature based on mounting
method and irradiance, it is common to use industry-accepted
factors based solely on mounting methods. These values are
added to the ambient temperature to estimate the array's
operating temperature.
The racking correction temperatures are applied to the
highest average ambient temperature at the array's location:
• Parallel to roof (<6 in. standoff): +35°C
• Rack-type mount (>6 in. standoff): +30°C
• Top-of-pole mount: +25°C
The highest temperature used is generally the average
high temperature during the summer months, although some
designers prefer to use the annual record high temperature for
this calculation. Using the annual record high temperature for
the calculation is a more conservative approach that ensures
that the array will operate in all conditions it is subjected to
without dropping below the inverter's voltage window.
After the module's voltage is corrected for maximum
temperature, this value is divided into the component's
minimum voltage window. The result is a fractional value
that must be rounded up to the next highest whole number,
since at times the array will be operating at temperatures
higher than the average value used.
When determining the minimum number of modules in
series, designers need to be careful not to design a system
that will normally operate at the very bottom of the voltage
window. An array's voltage that consistently drops to or
near a component's minimum window on "average" days
increases the possibility of reduced energy output on days
that exceed the average temperature. And, while PV modules
C K * — - -»» -■ ■« ■ ■ i - 1
XBntTEX
are built to last, some degradation occurs over time. This is
primarily due to moisture ingress that gradually corrodes
a module's internal electrical connections, creating higher
resistance that, in turn, results in lower operating voltages.
In extreme cases, this voltage degradation could amount
to as much a 1% annual drop in module voltage. So you'll
also need to account for this over the array's lifetime. Given
these considerations, designing string sizes well above the
minimum acceptable voltage level is sound system design.
Access
Ryan Mayfield (ryan@renewableassociates.com) has a degree in
environmental engineering from Humboldt State University and lives in
Corvallis, Oregon. He teaches PV classes at Lane Community College
and Solar Energy International, and is a principal at Renewable Energy
Associates, a firm focusing on PV system design, implementation,
commissioning, and industry-related training. He holds a Renewable
Energy Technician license in Oregon.
Online String Calculators:
Fronius • www.fronius-usa.com
Kaco • www.kacosolar.com
PV Powered • www.pvpowered.com
SMA America • www.sma-america.com
Solectria • www.solren.com (charts only)
Xantrex • www.xantrex.com
home power 125 /june & july 2008
RV Solar Packages
Natural Light Solar Attic Vent/Fan
10W&20W Modules
alternative energy store
www.altenergystore.com
Shop online 24/7 or call now (M-F, 9AM-7PM EST)
Toll-free: 1.877.878.4060 or Direct: +1.978.562.5858
Learn about Renewable Energy
with our new Webinars!
Energy Basics • Solar Air Heating Basics • Solar Electricity Basics • More to come!
Now available online at: http://learn.altenergystore.com. Sign up today!
Remember to use code HP125 for an extra discount!
Xantrex XW
Inverter/Chargers
Successor to the robust,
well-regarded SW series.
True sine wave, 120/240-volt
AC, split-phase, inverter/char-
ger that incorporates a DC to
AC inverter, a battery charger,
and an AC auto-transfer switch.
starting at $2,599
Southwest Windpower
Air Breeze Wind Turbine
Quieter, more efficient, and
precision engineered to
deliver more energy at lower
wind speeds than any other
wind generator in its class!
starting at $557
“Making renewable do-able”
The Alternative Energy Store is
the premiere retailer of renewable
energy goods. We provide not only
the expertise and the technical
service the Do-It-Yourselfer needs,
but also a place for learning &
sharing with others who have
the same passion.
We make renewable do-able.
Power your RV with the sun!
Packaged systems in stock and ready to go.
(Airstream not included!)
starting at $139
Sun-Mar
Garden Composters
Reduce your contribution
to landfills AND produce
beautiful compost for
your garden!
Made in the U.S.A.! Get
'em while we’ve got 'em!
starting at $288
Apollo Solar
T-80 MPPT Charge Controller
Reduces the cost of your solar electric system
dramatically by reducing the number of PV panels
required, decreases your need for expensive
I illl 1 , heavy gauge wiring, and gives you
the freedom to grow to a large system
as you can afford without buying
another controller. Up to 35% more
HII efficient than traditional solar charge
controllers and you can upload
charging data to a < 1*790
PC or
the ‘net.
A simple and environmentally sensible solu-
tion that can save you money!
Powered completely by solar
energy, these efficient
units are installable by
the do-it-yourselfer.
starting at: $350
We even
Solar Panels
Call today for updated pricing
and availability on your favorite
solar module brands!
eveignew '2 KSDLtud
t A tWV and many
more!
P3 International P4400
Kill-A-Watt Power Meter
Use the Kill-A-Watt Meter to
discover how much energy
your appliances and electronics
are REALLY using and where
you can start saving on your
electricity bills!
$33
Great Prices • Friendly Service • FREE Online Educational Materials • NEW! Public Renewable Energy Training Workshops
Puzzled? We’ve Got the Solution.
A well designed renewable energy system is much more than a pile of hardware.
We live on renewable energy, have 20 years of
experience, and have established over 500 systems.
Your best resource is a local pro. Tap into our network
of qualified, competent Electron Connection associates
across the country.
Installing RE and looking for a competent distributor?
Why talk to a sales technician when you can talk
to an electrician? We know what works and how it
works. We offer technical support, system design help,
prompt shipment, fair pricing and NO BULL. Local
referrals always. Electrical competence required.
Bob-0 Schultze
CA Electrical Lie #
613554
OR CCB Lie #
149724
Authorized Distributor Authorized Distributor
■■wfcl 91 r LI r I i ■
Authorized Distributor
WE PROVIDE COMPLETE SERVICE:
• Solar
• Wind
• Micro-hydro
• Water Pumping
• Load Analysis
• Local Site Survey
• System Design & Installation
• User Training & Tech Support
Inert USB
Authorized Distributor
800.945.7587 toll free
www.electronconnection.com online catalog
P.O. Box 203, Hornbrook, CA 96044 U.S.A. • Voice/Fax: 530.475.3401 • E-mail: bob-o@electronconnection.com
inter
solar
North America
July 15-17, 2008
i Francisco I California I Moscone G your place
Intersolar North America will be the
largest exhibition serving the entire solar
technology supply chain in the United
States. The event focuses on photovoltaic
technologies, solar thermal technologies
and solar architecture.
5EMIGON
ESS
nfeture: SynPow^ Corporation- « - S _
www.intersolar.us
mping Water
ith Sunshine <
by Erik Lensch
One of the simplest and most
economical uses of solar
energy is for pumping water.
With advancements in pumps
and pump controllers, solar
water-pumping systems have
become fairly easyio install,
operate, and maidfSilm^ /
If you live beyond the reach of the grid, or have a remote
pumping need like irrigation or livestock watering,
a solar-electric pump system can be a solution that's
reliable and sustainable. This article covers the basics of
several types of PV-powered pumping systems, including
array-direct, battery-based, and both pressure-tank and
high-volume water storage.
Solar Pump Types
There are two basic types of solar water pumps —
submersible and surface. In this article, we'll be looking
primarily at submersible pumps used to deliver potable
water for domestic use. A submersible pump is usually
positioned in a well, although there are instances
where a stream or pond is used as the source. Unlike
surface pumps (installed above the source's water
level) that draw water up from shallow sources like a
pond, submersible pumps push water up to a holding
tank or pressure tank. The right-sized submersible can
pump water out of deep wells, up to 1,000 feet or more.
Most models are durable and can tolerate water with
relatively high levels of silt.
Submersible pumps break down into three main
categories — centrifugal, helical rotor, and diaphragm.
Centrifugal pumps have an impeller that spins at high
speeds, producing a high flow of water. Because the
spinning rate is high, the flow rate is generally high.
However, pressure, and therefore the amount of pumping
height (head or lift) that can be attained, is usually lower
than in other types of pumps.
Higher lift can be achieved with helical rotor pumps
(a type of "positive displacement" pump), which will also
provide a flow rate great enough to meet most household
demands. With these pumps, picture the water being sent
out of the pump body in small "packets" that are pumped
very quickly to provide a constant flow. An analogy that is
sometimes used is that of a spiral staircase in a sealed shaft,
with the staircase spinning around very quickly. Each "stair
step" lifts water toward the top of the pump, then to the
k pump outtake, and eventually out the top of the well.
Since the water needs to be carried through the pump
body, the result is a lower flow compared to centrifugal
pumps. However, with its higher pressure, a helical rotor
pump can deliver water against higher heads.
home power 125 /June & July 2008
pumping
Depending on the model, submersible diaphragm pumps
(another type of positive displacement pump) can pump up
to about 5 gpm from shallow wells (under 100 feet), or lower
volumes from well depths down to approximately 250 feet.
A 4-inch well casing is typically required. Although these
pumps are less expensive than centrifugal or helical pumps,
they require significantly more maintenance.
Different models of submersible pumps are designed to
run on AC, DC, or both. To simplify wiring, off-grid residences
with AC PV systems often rely on an AC submersible pump.
It's important to note that most "AC" pumps actually
utilize brushless DC motors. In this case, the pump contains
electronics that allow it to be powered by a standard AC
source like an inverter or the grid. The pump is just another
AC load to be considered when sizing the system's battery
bank, inverter, and charge sources. Many AC pumps will
require two or more times the power (wattage) to start the
pump than is needed when the pump is running, and the
system's inverter needs to be able to handle this extra start-
up load. The Grundfos SQ series of pumps is very popular in
the off-grid world. These pumps have no start-up surge, and
have a great reliability record in the field.
But DC submersibles take more efficient advantage of
battery-based PV systems compared to AC pumps. AC pumping
includes DC-to-AC conversion losses: A PV array's direct
A pump controller
like this SunPumps
PCB-180BT balances
PV voltage and
current to optimize
pump performance
throughout the day.
current is stored in batteries before being converted to AC by the
system's inverter, which in turn, powers the pump. Inefficiencies
associated with the charging and discharging of batteries can
account for losses of 5% to 10% or more, depending on the age
and condition of the battery pack. And with an inverter average
conversion efficiency of approximately 85%, an AC pump will
require approximately 20% to 25% more PV energy to pump the
same amount of water compared to a DC-direct pump.
Submersible Pump Types
A DC submersible diaphragm pump (middle)
and a centrifugal pump (right), with controller
(left), by SunPumps.
www. homepower . com
pumping
Component Considerations
For either PV-direct or battery-based solar water pumping, the
following design practices can ensure a top-notch system that
maximizes your investment.
Site Right. For optimal performance, the array must be free
of shading during the day and must be facing as close to
true south as possible. For most residential water-pumping
systems, the modules are set at a fixed tilt. But for applications
that require a lot of water pumping during the summer, like
irrigation, a sun-tracking PV module mount can maximize
power production and pumping.
Trackers keep the modules perpendicular to the sun as it
moves through the sky, providing more power to the pump
over a longer period of the day. In the summertime, a tracked
system with a clear horizon-to-horizon solar window can
provide 20% to 40% more water than a fixed array.
Minimize Voltage Loss. To limit wiring voltage loss and minimize
the length and the gauge of wire needed, locate the PV array as
close to the pump or battery bank as possible. The greater the
distance from the PV modules to the pump, the greater the
voltage drop. Too much voltage loss can significantly reduce the
amount of water pumped, and in some cases may be so great
that the pump will not operate effectively.
Voltage loss should not exceed the accepted standard of 2%.
For long distances, wire size must be increased, at additional
expense. With the price of copper at an all-time high, it's
usually cost-effective to locate the array as close to the pump
or battery bank as possible. Your system designer can provide
the wire-sizing calculation for you, or you can use software
provided by the pump manufacturer.
Free Flow. Pipe friction is another important factor in
optimizing pump production. The greaterthe distance between
the pump's outtake and the delivery point, the greater the
flow restriction from pipe friction. Much like voltage drop
can be mitigated with larger wire size, flow restriction can be
reduced by increasing the pipe size or reducing the distance.
For household use, 1.25-inch- or 1.5-inch-diameter pipe is
typical. However, if the distance exceeds 500 feet or the flow
rate is expected to be unusually high, consider increasing the
pipe diameter to 2 inches to keep friction losses down.
Pump Protection. To regulate flow, pressurized systems use a
pressure switch. If a holding tank is used, a float or level switch
turns off the pump when the water rises to a certain level.
Some pumps require a "reverse-acting" pressure switch.
Most pressure switches operate by closing the contacts when
the pressure has risen to a preset point. Conversely, in a
reverse-acting pressure switch, the contacts open when the
pressure falls to a certain level.
Just as important is providing a shutoff mechanism for the
pump. Damage can occur to the pump if it pumps against
"shutoff" head when the holding tank is full and there's no
overflow pipe or float switch in place. And to avoid damaging
the pump if the water source runs dry, use dry-run protection (a
water-level sensor) at the source. Some pumps have this built in,
so check a given pump's specifications.
Under Control. All submersible water-pumping systems should
have a controller between the power source and the pump. In
PV-direct systems, the control can be as simple as using a linear
current booster (LCB). An LCB optimizes array voltage and
current, maximizing the volume of water pumped and helping
the pump start sooner in low-light conditions. More advanced
controllers include pump motor speed-control and low-water
cutoff circuits. Some even provide information related to the
system status, including how many watts the PV modules are
producing, and can be helpful for system troubleshooting.
Most pump manufacturers offer one or more controller options
designed to be used with their pump model.
Arresting Lightning. Proper system grounding will usually
protect the pump and control. But some manufacturer warranties
also require a lightning arrestor be installed. As with any PV
system, the array and its modules should be properly grounded.
While a direct lightning strike will likely damage the controller,
the pump may survive if the system is well-grounded.
Lorentz manufactures a range of pumps, some of which
operate at up to 200 volts open circuit. Centrifugal DC pumps
manufactured by SunPumps operate at up to 245 Voc. They
offer models that can pump 4 gpm from wells up to 650 feet
deep, or up to 250 gpm from shallow wells or surface water
sources. SunPumps and Shurflo also make less expensive
diaphragm pumps that can be good choices in array-direct
(batteryless DC from PV modules) applications for domestic,
irrigation, or livestock watering, provided that the water is
relatively silt free.
Grundfos manufacturers the SQFlex, a centrifugal pump
that can run on either AC or DC power — no special equipment
is needed to make the switch. In DC systems, the pump only
requires 30 VDC to get going, but the pump's 300-volt open-
circuit limit allows the array to be wired at higher voltages,
decreasing both wire size and cost. With the addition of a
generator interface box, the pump can be switched to accept AC
power from a generator during sunless periods.
A Lorentz PS150 Boost diaphragm
surface pump is typically used to
pressurize water systems.
home power 125 /June & july 2008
Solar Pumping Systems
There are three general solar water-pumping system types.
Your best solution will depend on elevation changes at your
site, whether there are inverters in your system, and how much
flexibility you have when it comes to when you pump water.
Array-Direct to Elevated Storage. The most efficient
solar water-pumping systems are PV-direct without
batteries. This classic off-grid pumping solution connects
a DC submersible pump directly to the PV array. One
additional component, either a controller or linear current
booster (LCB) wired between the PV array and the pump,
optimizes the relationship between array voltage and
current to maximize the amount of water pumped under
varying sunlight conditions. When the sun is shining, the
pump moves water to a tank located above the water's point
of use. (For potable water, use only drinking-water-grade
tanks.) For each 2.31 feet of elevation, there will be 1 psi of
water pressure. Many household water supplies operate
at about 40 psi (though down to 20 psi can often work),
so locating the storage tank about 100 feet higher than the
point of use will provide adequate water pressure.
The beauty of these systems lies in their simplicity.
The tank acts as a large "battery," storing the pumped
water for later use. And since the elevation of the tank
provides the needed water pressure, no pressurizing
pumps or pressure tanks are required. For household
domestic water systems, I recommend sizing the storage
tank to hold at least five days' supply of water to cover
those inevitable periods of cloudy weather. If properly
sized, the pump will slowly fill the tank when the sun
is shining. When the sun isn't shining, the pump doesn't
run. It does not damage the pump to go on and off during
the day as clouds pass over.
Other advantages of PV-direct pumping are the efficient
use of PV energy (no losses to battery charging or inverter
conversion) and the potential for reducing generator
run-time. Off-grid system users often limit generator-
based charging (and the associated noise, pollution, and
fuel expense) by waiting to perform energy-intensive
activities — like running the vacuum or shop tools — until
there's plenty of solar energy available. This limits
battery bank depth of discharge to extend battery life. In
properly sized PV-direct to storage tank systems, several
days' worth of water will be stored in the tank. During
cloudy periods, you will already have pumped the water
you need, and the generator won't be needed to keep the
batteries topped off while pumping.
Array-direct to elevated storage systems will save
you money in the long run and add more flexibility to
your off-grid energy lifestyle. But keep in mind that
the additional expense of the tank and for trenching
the pipeline deep enough for freeze protection can
make these systems more expensive up front than other
options.
Array-Direct to Storage Tank with Pressure Pump. If you
like the efficiency of DC pumping and want stored water at
your disposal, but don't have enough of an elevation change
on your property for a gravity system, there are still options.
solar pumping
Array-Direct to Elevated
Storage
Float Switch
Storage Tank:
Elevated 2.31 ft. for every
psi of pressure needed;
sized for days without
Static Water Level
Drawdown Level
DC Submersible Pump:
Sized for head to tank inlet
Array-Direct to Storage
Tank with Pressure Pump
Photovoltaic Array:
Sized for pump load
Well
StorageTank:
At grade; sized for days
without sun
Static Water Level
Drawdown Level
DC Submersible Pump:
Sized for head to top of tank
www.homepower.corn
3lar pumping
A PV-direct DC pump can be configured to fill a storage tank
near its point of use, and an additional DC or AC booster
pump can be installed at the tank to pressurize the water. This
solution gets the heavy lifting (from the well to the storage
tank) done whenever the sun's shining, and limits energy
use during cloudy periods to a smaller pressure pump that
activates via a pressure switch when water is used.
While this configuration gives you more flexibility to
choose when you consume the energy required to pump well
water, the up-front costs of the storage tank and additional
pressure pump add to overall system cost and installation
complexity.
Pump to Pressure Tank. The most conventional of the
three pumping systems described uses an AC submersible
pump to push water directly to a pressure tank. A DC pump
sized to meet the site's flow rate requirements can also be
run directly from the battery bank, eliminating inverter
conversion losses. A standard pressure switch activates the
pump when the pressure in the tank drops below a set level,
say 30 psi. At 50 psi or so, the switch's upper-limit shuts off
the pump. Instead of a 1,200-gallon or larger water storage
tank, a smaller 40- to 60-gallon pressure tank is all that is
needed.
Compared to the systems described earlier, pump-to-
pressure tank systems usually have the lowest up-front
component costs (there's no large storage tank or secondary
booster pump), and pump installers everywhere are familiar
with these systems. But they may not be familiar with the
limitations of battery-based power sources (pump surge,
inverter capacity issues, and the like), so pay close attention to
Pump to Pressure Tank
Photovoltaic Array:
Sized for pump load
or part of whole-house
system
Battery:
For pumping
at any time
Pressure Tank:
Charged by well pump,
maintains house pressure
Inverter: If AC system
(not shown)
Pump
Controller
Well
Point
of Use
Static Water Level
Drawdown Level
AC or DC Submersible Pump:
Sized for head to point of use,
plus final pressure
Installation of a Grundfos SQFlex submersible pump.
the pump's operating characteristics and seek out an installer
familiar with off-grid pumping systems whenever possible.
For off-grid installations, the downside of pump-to-
pressure tank systems is that the pump will need to come
on during most water draws. During cloudy weather or
overnight, the energy to repressurize the tank will come
from your battery bank. Batteries like to be fully charged,
and the deeper you discharge them and the longer they stay
in that state, the shorter their service life will be. Another
consideration is that, compared to array-direct systems with
high-volume storage, increased generator run-time during
cloudy weather will be a necessity.
Access
Erik Lensch is the owner of Innovative Solar Solutions
(www.innovativesolar.com), based in Charlotte, North Carolina.
Formerly SC Solar, the company has been designing and supplying
solar water-pumping systems since 1999.
Submersible Pump Manufacturers:
Conergy • www.conergy.us • DC pressure & surface pumps
Grundfos • www.grundfos.com • AC & DC/AC submersibles
Lorentz • www.lorentz.de • DC pumps & solar trackers
March • www.marchpump.com • AC & DC pressure pumps
Shurflo • www.shurflo.com • AC & DC pressure pumps & DC
submersibles
SunPumps • www.sunpumps.com • DC pressure
& submersibles
home power 125 /june & july 2008
GPS monitoring station at Cape Roberts, Antarctica operates year-round with solar power and a large bank of Deka Solar Gel Batteries.
How Far Off The
PROVEN PRODUCTS IN DEMANDING PHOTOVOLTAIC APPLICATIONS U.L. RECOGNIZED COMPONENTS COMPETITIVE WARRANTY MADE IN THE U.S.A.
Photb Courtesy of UNAVCO
EAST PENN INTERNATIONAL INQUIRIES:
manufacturing co.,inc. 610-682-3263 9 www.dekabatteries.com
DOMESTIC INQUIRIES:
800-372-9253 9 www.mkbattery.com
No matter where you are, depend on Deka Solar.
Antarctica is the coldest continent on the planet. Only the toughest plants and animals are
able to survive the cold. And the same goes for your batteries. So when a government
funded agency needed to deploy a photovoltaic system for monitoring land mass
movement in this harsh environment, they chose Deka Solar Batteries.
Whatever the demands of your renewable energy application, Deka Solar Gel/AGM
or flooded batteries are the proven choice.
NEW from MORNINGSTAR . . .
TM
Maximum PV input of 400W
• Enables use of high voltage
modules up to 75Voc
Converts up to 36 volt PV to 24V
or 12V battery
• Provides power boost and
maximizes PV output
• Smaller and less expensive than
other MPPT controllers
jidjil&t Mm
Solar Controller with Maximum Power Point Tracking
Please Visit Us at the MREA Energy Fair BOOTH A20
O MORNINGSTAR
1Y1 corporation
Phone: +1-215-321-4457 Fax: +1-215-321-4458
info@morningstarcorp. com www.morningstarcorp. com
www.homepower.com
The Solar Thermal Contractor’s Bible!
DOWNLOAD NOW
fJ^www ihu fan* you &vk
LW fikmtt jlrii'.^Af rf Ctntayrra
J CTm^uw 7 tVwfr Wdi i
iwwvr,«c 3 ' 9 glar,cent
1
f.fw w£ J 2 i'
Sotar Hal Water, Solar Space H eati ng.
and Pool Healing; Installation and Ltestgn
High Performance-Law Maintenance Systems
Reality Checks Using Current Technology
In this ckalmiCsve ?30- page manual, solar cnrgy pwnDer
Tam Liw, In 20&& IrwlUettii Into thfl lull or f ume,
tiuC&nes how E lie laleit Eechndegy and valuable lossens laamed
from the past can help a new ger eraticn of solar contractors
eipa nd their hiisinraus and liCisfy Ifttlf ciiitGflnen .
Urzfcf miimhit frtw w.tfcs-sdjr.-eanO sm eredif card
ar land 1 frhwt or -moniv rm
Energy Conservation Services
5JM Siv J3<*| St ■ dWmMfe fL $2603
OSH} 3fMB6&
i"rJcn Ii&SimL' DtspKS ? Sil S e»di — S_
K*i> and Vi r HCti EtiMft . C^rfcii ff &JB <*idi *
l>GMTwisr:iG Shipping ariirHais<il*iQ; S i.M
TOTAL: 5_
Solar Converters Inc.
IVe design and manufacture Power Con frof SoJutrons for your PenekvaJife Energy Systems?
Li nea r Currant DC ^ Battery Linear Voltage Generator
Boosters Autotransformers DttlllphJtOrl Boosters Starter*
frmuu Mar Pmrw
PctfamwKa
BFTpt
r FlfHti U.l^ijl
B*-BttVGtrariw} K*QC
Comwlwt
t ftafUPjs ■ Eqiijlir
‘CffWl* F,ir*fv Pptf to
DMwIWtW]
- U£ I to Gtfrfcm
t.r* rtdi tsiftn^Lirr
* 6mwt
■ WjvWWl F\it» Sain?ti
K«Apx a Conitifrt flfttwy
WHY#pf-toynurtgu^enr
J tah*Y *vn i
LiwUil^
- WBhf ftdTip Eo»i#f ifid
GMolv
Sfjrta / di l Lf>5 GttnS-rfi iMBfld
an
»Sfl^ipnifi94iv
k TmfCenw i tlM
also 4 MPPT Power Ti 3 Gker lv Charge Coelr oilers * Voltage Controlled Switches
• Catfnd ic Proteclion Controllers * Solar Lighting Conlrollers
Please visit www.solarconverters.coTn for MORE products and details
CM» Victoria Road S. Guelph, On. Nl£ &T 9 , Canada Plmna ■: SI 9 -! 2 <-S 2 Xi Fan: 5 l«! 2 IHJ 325 tmall: lnto<gstf areMivcrtcf sjcom
home power 125 /june & july 2008
BackHome
Magazine
Free
Wind Turbine
..Plans
lira BackHome
FROM — Ml"
Wind
Build Your Own
Low Cost >
Wind Turbine 1
Wbs* 1 1
.$400 Estimated Cost ^
This low-cost, high-output f
Subscribe to
BackHome
for just
turbine is constructed of
$21.97 per year.
salvaged materials and can be
Call us at
built for about $400. To receive
800-992-2546,
your free PDF download of this
write to us at
plans booklet, just go to the
P.0. Box 70hp,
Web site below for details
Hendersonville, NC
and learn how BackHome can
28793 or visit our
“EM-POWER” you.
Web site
www.BackHomeMagazine.com
“Its hard to imagine a more comprehensive, and
comprehensible, guide to making your home work for you
and for the planet, inside and out. Its frugal, its sensible, and it
will help!” — Bill McKibben, author of Deep Economy and
Fight Global Warming Now
THE
CARBON-FREE
HOME
3ft ■■'■ iil lli| n l-atlt li Hip-
Chelsea
Green
PUBLISHING
the politics and practice of sustainable living
Visit us at:
chelseagreen.com
800.639.4099
Quality First!
TM
Inc.
SOLAR PUMPING PRODUCTS
Brushless DC Submersible Pumps
up to 2 HP. Heads up to 650 feet
and flow rates up to 250 GPM.
Diaphragm Submersible
Pumps with heads up to
230 feet and flow rates
up to 5 GPM.
Centrifugal Booster Pumps
from 24 volt battery home
pressure systems to 180
volt panel direct systems,
6 GPM to 30 GPM.
DC Pool Circulating Pumps
from y 2 HP to 1 y 2 HP,
20 GPM to 100 GPM.
PCA & PCB SERIES
Micro-processor based pump
controllers up to 3 HP.
Current boosting and voltage
boosting models available.
PUMP CONTROLLERS
SHARP
For more products and services
check our web site on-line at:
www.sunpumps.com
Phone:
Fax:
1 - 800 - 370-8115
( 928 ) 348-9652
( 928 ) 348-9653
www.homepower.com
81
_
F
T7
For 28 years, my company has been
helping its customers meet their energy
needs with the power of the sun, but
only recently, with our move into a
new headquarters, have we been able
to walk our talk by operating in a net
zero-energy facility. When I started this
business, working with only a part-time
plumber, I never would have imagined
that the company would grow to a
team of more than 20 employees. With
each new employee, I've become more
and more aware of the energy impact
of our day-to-day operations.
home power 125 /june & july 2008
net zero
I n 2002, after almost ten years working out of a solar
demonstration home that I had built near downtown
Portland, Oregon, I moved our offices into a nearby
commercial facility. Though the building suited our operations
in many ways, it had one major drawback: The landlord
would not allow us to put PV or solar hot water systems on
the roof.
Because I'm in the solar business, I dreamed of housing
our offices and warehouse in an energy-efficient building
with solar systems providing 100% of our energy needs.
Though I initially had mixed emotions about starting over in a
new building, I began to see the move as an opportunity — the
first step in achieving zero net-energy use.
Of course, while energy efficiency was a high priority, I
had other considerations too — namely, I needed a loading
dock. At our previous location, wheeling a 14-foot solar
collector down the hallway, out the door, and hoisting it up
onto the truck while cars sped by only a few feet away was
precarious to say the least. So when I found a south-facing
building with loading docks, it was a double bonus. The fact
that the building was in a highly visible spot near Portland
International Airport made it that much more appealing.
Plus, the location was central to the city and Vancouver,
Washington, where we perform most of our installations.
The 10,000-square-foot building had been built as a
sandblasting facility in 1950. More recently, it had been used
by a trailer manufacturer, with a portion of the space divided
into offices. The building was sturdy as a rock and had both
single-phase and three-phase electricity. On the other hand,
it was filthy, and the low ceilings and lack of windows in the
office area made it dark and gloomy. For six months, I resisted
purchasing the building just because I dreaded the work that
I'd need to do to get it into shape.
In December 2005, I finally gave in. The plan was to
expand the existing office area, which had been sectioned into
small rooms, to accommodate our showroom. The remaining
8,000 square feet with 16-foot- tall, open- truss ceilings would
become a warehouse, shop, and production area.
Getting Comfy with Efficiency
From an energy and comfort standpoint, the building was
a disaster — and I wanted no part of the $l,500-per-month
energy bills that the previous occupant reported. The office
area had only two windows. The carpet was more blackish-
gray than beige from years of hard wear and greasy boots.
The whole space smelled like a mechanic's garage. Light-
defying walnut paneling engulfed the four office walls. The
ceilings were oppressively low and dingy.
Improving Insulation. The only insulation in the building
was ancient R-ll fiberglass batting haphazardly placed above
the false ceilings in the office area. The first order of business
was to blow an 18-inch- thick layer of new cellulose insulation
right on top of the fiberglass. This filled in many of the voids
and raised the insulation value in the attic to an estimated
R-50.
The building's exterior walls are 1-foot-thick concrete.
The interior wall surface was furred with wood nailers
and covered with paneling. We attached R-16 rigid-foam
insulation sheets directly over the existing walls and installed
new drywall over that. Though the layering reduced the size
of our already-small offices, the added insulation made all the
difference in comfort.
Next, we searched for air leaks. We sealed all the ducts,
replaced broken window panes, and weather-stripped the
outside doors. Because all the electrical outlets and switches
had to be extended 2.5 inches to accommodate the thicker
walls, we even sealed out any drafts around the boxes with
insulation pads specially made for this purpose.
Lighting Strategies. The building's only natural light came
from a bank of inoperable, steel-framed, single-pane windows
Glass blocks, filled with water and dyes, are part of the
showroom's daylighting strategy.
Natural sunlight,
provided by tubular
skylights, brightens
the office space.
a
net zero
Tubular skylights bring sunlight into interior spaces to reduce
daily lighting loads.
on the south and west walls. A fresh coat of light-colored paint
covered dark, ugly interior walls and helped to brighten the
office space some, but the building needed serious help in the
lighting department. We swapped out the existing 10-kilowatt
lighting system — 40 industrial light fixtures drawing 250
watts each — with industrial-sized tubular skylights, reducing
the need for supplemental lighting during the day. Eight
tubular skylights provide 90% of the lighting for the shop/
warehouse space and office during business hours.
Next, we added two tube-fluorescent fixtures for task
lighting in the production area. For our most creative lighting
project, we fit 1-foot-square glass blocks — filled with water
for thermal mass — into the frames of a permanently locked,
south-facing garage door that had been covered with drywall
by the previous owner. For an interesting and colorful effect,
we added yellow and orange dye to the water in some of the
glass blocks.
All of these upgrades
dropped our lighting
load from 80 KWH to
approximately 2 KWH per
day, reducing our lighting
costs by $240 per month.
The skylights cost about
$1,000 each, installed ($450
materials; $550 labor). At
present electricity rates, it'll
take us less than three years
to recoup our costs.
Solar Water Heating.
Within a year of moving into
the building, we installed
The storage tank (left) and
the hot water collectors
with the module for the DC
pump (right) make up the
solar water heating system,
which provides 100% of the
building's hot water.
a solar water heating system and removed the backup
electric water heater. Solar energy now provides 100% of the
building's hot water, which serves two lavatories and two
showers in the bathrooms. The system features a 56-square-
foot thermal collector typically suited for a family of four.
We located the solar storage tank in the showroom area so
visitors can observe the water temperatures from the solar
collectors — typically 140°F in the summer and 80°F in the
winter. Even on the cloudiest days, visitors are pleasantly
surprised to see the results of the system's PV-powered pump
(a 12-volt DC Hartell pump directly powered by a 36 W
module) in the glass flow meter.
Space Conditioning. The mass of the slab-on-grade
concrete floors in the building help moderate interior
temperature swings. In the summer, the cool soil below
the concrete floor tempers summer temperatures, while an
awning shades the south-facing side of the building and
prevents the summer sun from charging the concrete floor
mass. As a result, our air conditioning unit is never used. On
sunny wintertime days, the concrete absorbs solar energy,
providing some offset for the electric air-source heat-pump
system that serves the office space.
To improve the efficiency and operation of the heat-pump
system, which was installed in the 1950s, I hired an HVAC
contractor to inspect and service the equipment. He inspected
the ducts, sealed air leaks, and replaced the dirty, blackened
filter that looked as if it was original to the system. For added
conservation, I installed a programmable setback thermostat.
Heating 2,000 square feet of segregated space efficiently
takes some creativity and staff buy-in. Employees dress
warmly in the winter, when the thermostat remains at 65 °F
during work hours. As needed, a 1,000 W radiant electric
heater supplements the main heating system in the colder
back offices. Overnight, the programmable thermostat allows
interior temperatures to drop as much as 20°F. But because the
functional mass of the concrete floor tempers heat loss through
the night, the space reheats quickly — about an hour after the
thermostat turns on the heating system in the morning.
The 8,000-square-foot warehouse is mainly used to store
vehicles and renewable energy equipment inventory, so heating
and cooling it is less of a priority. In the winter, which tends to
be mild and mostly overcast, another 1,000 W electric radiant
heater keeps temperatures tolerable in a production area. In the
summer, two solar attic fans help by drawing hot air out.
home power 125 /June & july 2008
Running the Numbers
After almost two years of tightening our energy belts and
making efficiency upgrades, we were ready to calculate what
it would take to reach net zero-energy usage. Our utility.
Pacific Power, made it easy by providing a bar graph with
the average daily KWH consumption for each month of the
year. Upon poring over a year's worth of utility bills, we
determined that our PV system would need to average at least
23 AC KWH per day to offset our usage.
From my experience, this load was on par with that
of a highly efficient, all-electric home with passive solar
design and solar hot water, and in which occupants practice
energy conservation. In our case, besides space heating, we
power one laptop and four desktop computers, a photocopy
machine, a security system, and a dozen or so 15 W compact
fluorescent lights in the office and showroom. We also have a
total of six T-8 fluorescent tubes (32 W each) at task-lit stations
in the production area. On a typical day, there are also six
cordless-tool battery chargers plugged in.
Once we determined the load, it was time to size the
system. Peak sun is a standard measurement of the sun at its
brightest, and varies depending on the location's weather,
latitude, and other factors. One peak sun-hour is equivalent
to 1 KWH per square meter per day. In other words, a 100%
efficient solar module that's 1 square meter in size would
produce 1 KWH per hour under the best circumstances —
on the brightest day at high noon, with the PV module
perpendicular to the sun and at a time of year when the sun
is passing through the least amount of atmosphere. Of course,
PV modules are really in the 11% to 19% efficiency range, but
you get the picture.
Most inhabited places have between 3 and 7 peak
sun-hours per day. To calculate peak sun-hours in our
location, we used the University of Oregon Solar Radiation
Monitoring Laboratory's data. According to their analyses,
average peak sun-hour equivalents for a fixed PV array in
Portland are 3.9 hours per day. This assumes a true-south
orientation, no shading, and a 30-degree tilt.
We elected to mount the modules at a 15-degree tilt to
aesthetically fit them to the space we had. The shallower
For easier and speedier installation, the array was divided into
three-module subarrays.
angle reduces performance by about 4%, but the concession
for the array's more streamlined appearance was worth it.
We also recognized that there would be about 5% in losses to
convert DC to AC through the inverter, and an additional 1%
voltage drop through the wires carrying the solar-spawned
electrons. This added up to 10% in reductions for our planned
layout, leaving us with the equivalent of 3.5 peak sun-hours
(90% of 3.9 peak sun-hours).
It could be argued that a 15% correction factor might be in
order, allowing for temperature derating, soiling, and other
factors. However, we felt 10% would be a reliable number,
given Portland's moderate average daytime temperature
(62°F), plenty of rain to keep modules clean, and an awning-
mounted system with excellent backside air circulation that
keeps module operating temperatures lower than if they were
mounted parallel to the roof.
To calculate the size of the PV array we'd need, we
divided the average daily KWH load by adjusted peak sun-
hours to get the peak kilowatt rating of PV modules needed
to reach net zero-energy. Although calculations showed that
The Sunny Boy inverter, with the combined
DC/ AC disconnect, and a KWH production meter.
net zero
Mr. Sun Solar's Grid-Tie PV System
Inverter:
Sunny Boy SB 6000US,
6KW, 600VDC
max input,
250-480 VDC MPPT
operating range,
240 VAC output
o
o
Sunny Boy
AC/DC/Disconnect
Combiner, 15 A fuses
(representational)
® 0 ®©@©
Photovoltaic Array:
Thirty-three Sharp ND-208U1F, 208 W each at 28.7 Vmp,
wired in three series strings for 6,864 W total at 315.7 Vmp
Note: All numbers are rated,
manufacturers' specifications, or nominal
unless otherwise specified.
Utility KWH
Meter
we'd need a 6.57 KW array, it's good to oversize slightly.
As it happened, 33 Sharp 208 modules in landscape layout
perfectly fit the awning area we planned for the PV array.
This configuration gave us a DC-rated 6.86 KW and a 4%
margin of error in our estimate to reach zero.
To verify the sizing, I ran another calculation based on the
actual annual production of installed PV systems in the area.
I had good data from several customers. One in particular
had installed a 3 KW system three years prior. He found that
he was getting an average of 1,214 KWH per year for each
peak KW of PV on his roof. Using his real-world numbers,
I multiplied 1,214 and 6.864 (the size of our PV array) to get
8,333 KWH for the year. Dividing 8,333 by 365 days, I got 22.8
KWH per day — almost exactly what we needed.
System Rebates
Item
Amount
Initial cost
$67,500
Incentives
Oregon tax credit
-$27,000
Federal tax credit
-11,670
Energy Trust of Oregon rebate
-8,580
Total Incentives
-$47,250
Total Cost
$20,250
home power 125 /june & july 2008
net zero
Configuring the System
The array is comprised of three, 11-module strings, feeding
a single SMA America Sunny Boy 6,000 W inverter. The SB
6000US features a handy and time-saving extra — a built-in,
four-pole disconnect, so both the AC and DC can be turned
off with one switch. As required by Energy Trust of Oregon,
we installed a Centron permanent KWH meter to keep an
uninterrupted record of the system's AC output in the event
that the inverter might have to be serviced.
Before installing the system, we hired an engineer to make
sure the steel awning on the front of the building would
support a half-ton of additional module and racking weight.
Once we received the thumbs up, we got to work, mounting
groups of three modules together on the ground, which
allowed us to precisely set two parallel underside rails to
match the modules' bolt-hole pattern. Because someone had
recently stolen modules from a similar awning mount system
on a nearby building, we riveted cover plates over the bolts
the net meter and brought along a photographer to cover
the story for their company's newsletter. Our project was
apparently big news, as it had established the first "truly" net
zero-energy commercial facility in the company's six-state
service district.
Even as a solar installer who has personally completed
almost 2,000 solar projects, I still get a thrill when flipping
the switch for the first time. Ironically, the big moment was
delayed by a local power outage caused by a car accident that
had damaged a transformer. But we didn't let an outage slow
down the party. We quickly rigged a battery-based portable
PV system to provide electricity for lighting and music,
including the ever-so-appropriate Beatles' classic, "Here
Comes the Sun." We roasted hot dogs and baked cookies in
solar cookers.
Unfortunately, when we did finally flip the switch later
that day after power had been restored, we discovered a
as a theft deterrent.
Using a boom lift, we raised each three-module group
and positioned it on the frame. Four assistants put up the
whole PV array in a day. We had already installed the
inverter, had an electrician do the AC wiring, and ran
conduit while waiting for the engineering report. It just
took one more day to complete the DC wire run and then
the system was ready to go.
Throwing the Switch
On August 25, 2007, the day after we finished installing the
system, we hosted a "Throwing the Switch" open house to
celebrate. Representatives from Pacific Power came to install
Tech Specs
Overview
System type: Batteryless, grid-tie solar-electric
Location: Portland, Oregon
Solar resource: 3.9 average daily peak sun-hours
Average monthly production: 694 AC KWH
Utility electricity offset annually: 100%
Components
Modules: 33, Sharp ND-208U1F, 208 W STC, 28.7 Vmp
Array: Three, 11-module series strings, 2,288 W STC
each, 6.86 KW total, 315.7 Vmp
Array installation: Custom 1.5 in. aluminum square tube
mounts installed on south-facing awning, 15-degree tilt
Inverter: SMA SB 6000US, with integrated 15 A fused
combiner and AC/DC disconnect, 6 KW rated output,
600 VDC maximum input, 250-480 VDC MPPT operating
range, 240 VAC output
System performance metering: Centron Itron KWH meter
Paying for the System
Professionally installed PV systems in our area run about
$10 per peak watt. For the system I sized for our net zero-
energy building, I was looking at an investment of almost
$68,000. My first thought was, "Yikes! Where am I going
to get that kind of money?"
I considered the possibility of finding a third-party
investor, who would buy the system, take the tax credits,
utility incentives, and depreciation, and then lease the
equipment to our business. In turn, we'd pay rent on the
system for a cost roughly equal to the projected energy
savings. However, since this option is generally used
with larger systems, I had trouble finding a third party
interested in our relatively small project. I did eventually
have one taker, but in the end, the buy-out provision of
the lease asked for "fair market value," which could have
been $50,000 or more with appreciation — more than I
was willing to pay. I didn't want to end up paying for the
system twice.
Instead, I found unsecured private financing at 7%. A low-
interest loan through the state of Oregon's Solar Energy
Loan Program would have come with a slightly more
competitive rate, but the terms required that I take out a
second mortgage on the building — which didn't appeal to
me. Though I was not wild about taking on such a large
loan, the numbers were less daunting once I factored
in all the tax credits and incentives: an $8,580 rebate
from the Energy Trust of Oregon; a $11,670 federal tax
refund (30% of the system's cost, less the Energy Trust
of Oregon incentive); and a $27,000 state tax credit taken
over five years.
In the first six months of the loan, I recovered about half
of the loan amount. By the time all the credits come in, I
will have covered nearly 80%. With all the incentives, the
actual tax reduction from depreciation, and the value at
current electric rates of the energy saved by the system,
I estimate full payback in seven years. It was that easy.
With just a few pushes of the pencil, I went from "Yikes! "
to "Done deal!"
net zero
Phantom Protection
Any net zero-energy home or business must zealously
guard against phantom loads — energy that is gobbled
up even when equipment is turned "off." To slay these
energy wasters, we plug our photocopy/fax machine and
every computer into power strips that are switched off
every night. All devices with wall cubes are also plugged
into power strips. We even went so far as to do away with
a doorbell, and selected a microwave that does not have
an LED clock. The building is as phantom-proof as we
know how to make it.
An exception — over coffee — was almost made when
office java drinkers organized and requested an automatic
coffee maker. Brewing coffee and keeping it hot all
day was not something I was excited about, especially
since I'm not a coffee drinker. But we compromised — I
allowed the coffee maker, but only on the grounds that
it is turned off immediately after coffee is brewed, and
the coffee is transferred into an insulated dispenser that
keeps it warm all day.
technical problem — the SMA inverter kept blowing fuses. We
got the company's technical support on the phone and worked
through the possible scenarios. Based on their suggestion, we
decided to rewire and bring the three individual strings into
the inverter rather than combining them at the array.
A week later, with the rewiring complete, we gave it
another go on a gorgeous, sunny day. The system cranked
out 31 AC KWH on that first day. And the best part: Our new
Pacific Power bidirectional meter read zero when it was first
installed, and the first number recorded was -1. There was
nothing like watching the meter spin backward, knowing that
we were well on our way to net zero-energy use.
Access
John Patterson (jp@mrsunsolar.com) is president of Mr. Sun Solar
and inventor of the Sol-Reliant solar water heating system. Over
the past 28 years, his company has installed more than 1,900 solar
energy systems, including solar hot water, solar pool heating, and
photovoltaic systems.
Suzanne Olsen (suzolsen@integra.net) is a writer and photographer
specializing in renewable energy and the environment.
Tubular Skylights:
Naturalite • www.vistawall.com
Velux Sun Tunnel • www.veluxusa.com
PV System Components:
Sharp Solar • www.solar.sharpusa.com • PV modules
SMA America • www.sma-america.com • Inverter
SUPERIOR
AESTHETICS
SonFrame
CLEAN ENERGY NEVER
LOOKED THIS GOOD
Our SunFrame PV module mounting system is
engineered for exceptional function and design.
Whether you are planning for your home or
business, make an architectural statement while
taking your environmental stand.
Visit
to find a distributor near you.
UNIRAC
THE STANDARD IN PV MOUNTING STRUCTURES 7
www.unirac.com
home power 125 /june & july 2008
As per your request...
T-Rex
Charge Controller
200 Volts PV Voc
100 Amps output
All the T80 features
SOC Energy Meter
Wireless Remote
Optimal MPPT
cm
T80 Also
available
Off Grid
Inverter/Charger
Pure Sinewave
3600W 48V 3200W 24V
Split Phase 120/240VAC
Wireless Remote
Display
Apollo
Solar
www.ApolloSolar.com
203-790-6400
gr Solar
^^^iSotar
*P/<
c
} 1 SunWize
HU
Aunttrar
Visit us or write:
Backwoods Solar Electric Systems,
1589-HP Rapid Lightning Creek Rd,
Sandpoint, Idaho 83864 USA
For an earth restored and a world at peace.
Solar • Wind • Hydro
Specializing in Independent Electric Power for the Remote Home
where utility power is not available. For 30 years, your questions have
been personally answered by the good folks at Backwoods Solar that use
these products everyday. Each Backwoods Solar employee owns and
operates an off-grid home powered by the solar, wind, and/or micro-
hydro systems offered in our catalog. We know what works and how it
works! Our catalog /planning guide teaches the basics of installing solar,
wind and hydro electric residential power and we offer free system
design service either by telephone, email, or your visit to Backwoods.
Phone: (208) 263-4290 • Fax only (208) 265-4788
Website: www.backwoodssolar.com
Email: info@backwoodssolar.com
BACKWOODS
Solar Electric Systems
www.homepower.corn
SOLECTRIA
RENEWABLES
GRID TIED INVERTERS
for kW to MW systems
Best Volue
Fully Featured
Premium Efficiency
Easy to Install
www.solron.com PH 978.6S3.97QD FAX 978.6e3.97p2 C A 562.608.8913
o
CM
O
CM
a>
■d
o
BAnERY System
Monitor
Displays vital battery system data to help users
provide better battery care, increase conservation
awareness and aid system maintenance.
• Volts • Amps • Amp-hours • Min/Max volts
• Days since charged • Battery % full
• Remote locatable • About $169
Bogart Engineering • (831) 338-0616
www.bogartengineering.com
020 Two Bar Rd. Boulder Creek, CA 95006 USA
with more capability
Data logging, five customizable buttons and displays,
audible/visual alarms, three "amps" input channels,
relay control, computer interface
Is data logging really useful
in a system monitor?
When an offgrid system is first
installed everything usually starts
out working OK. But after awhile
it may not work quite like it used
to. Bad battery cell? Solar panel
developed a problem? You can
download the last few weeks of
logged data to your computer and
compare it to data recorded earlier
when everything was working
OK. Or email the file to some
other "expert" who can analyze it
without even coming to your home.
On our website download the document: " How to graph
and analyze renewable energy system performance using
the PentaMetric logged data".
The PentaMetric system with computer interface only is about
$320. LCD Display unit (above) additional $199.
See website for more information.
home power 125 /june & july 2008
Can something this beautiful really save you money?
Y
ou bet it can! The Sol-Reliant solar
water heating system will pay for itself
in energy savings within 3 to 7 years,
depending on your hot water usage.
Tax credits and incentives in some
states pay up to half the cost or more!
Sol-Reliant systems feature a photo-
voltaic powered pump. They’re easy to
install and reinstall after re-roofing. There ’s
no visible plumbing, and best of all, Sol-
Reliant systems won’t freeze or overheat.
OG-300 and Bright Way certified.
Designed to last over 25 years.
S#L-REL1AINT
The S&inr Fii'JJi-r f ft' titer Built To Last
Dealer inquiries welcome!
Call (888) SOL-RELY (888-765-7359)
CCB#33716
www.SolReliant.com
EnengyTruSt
f r I* -
Industry Leaders In MPPT
Solar Charge Controllers
Look For New Products & New Ideas In 2008
With the largest MPPT Solar Charge Controller product line
on the market today, Blue Sky Energy, Inc. has a controller
that’s right for your needs. From Solar Lighting, RVs &
Marine to Telecom & many other off grid applications,
Solar Boost™ Charge Controllers get the job done.
Visit www.blueskyenergyinc.com
Contact today for more info.
800-4Jr7877 or 760-597-164^
2598 fortune Way, Suite K,
■S^A92081 USA
Hueskyener 2 yi 11 c.com
SOLAR PUMPING LIGHTING
MARINE OFF GRID HOMES
QUALITY....RELIABILITY....BLUE SKY ENERGY, CHANGING THE WAY SOLAR IS USED EVERYDAY
www.homepower.corn
91
Chuck Marken
with Doug Puffer
F or most of us, performance matters, whether we're
shopping for a new car or choosing a solar water heating
system. For cars, their estimated fuel economy — miles
per gallon — can influence which model offers the best
value. Although these EPA testing numbers aren't necessarily
"real-world," they can give us a guideline to go by. Solar hot
water (SHW) system performance is not much different. In
this case, systems are evaluated by an independent testing
agency — then certified by the Solar Rating and Certification
Corp. (SRCC). And their ratings are the next best thing to real-
world performance.
Considering Your Choices
Our list of solar water heating systems is condensed from
the SRCC's Operating Guidelines 300 (OG-300) catalog, since
we didn't have room to list the more than 500 SRCC certified
systems. Instead, we tried to include every SHW system
manufacturer, but pared the list to 130 individual systems,
which were selected by two criteria: typical residential tank
size (40 to 120 gallons) and typical collector sizing (1 square
foot of collector area to every 1 to 2 gallons of water stored).
Only seven or eight efficient systems per manufacturer
were included in each climate category. To compare apples to
apples, all the systems listed in our table are assumed to have
electric backup heating. The included data is current as of March
1, 2008 — for updates, visit the SRCC Web site. If you want a
more detailed look at all the systems, but don't want to wade
through the SRCC's 309-page catalog, check out our complete
spreadsheet of OG-300 systems at www.homepower.com.
System Certification
In HP123, we featured a guide to selecting a solar hot water
collector — the "engine" of a SHW system that gathers the
energy. While the collector is the most important component
in a solar water heating system, it is only one component of
several that work together. Once the energy is gathered, it
needs to be stored for on-demand use. The other components
of an SHW system facilitate the storage and distribution of
the solar-heated water, and greatly influence how much hot
water is available.
While choosing a collector is important, knowing how the
entire system will perform is crucial. And getting an idea of how
one system stacks up against another will help you maximize
your investment. The SRCC OG-300 standards provide a
relative performance comparison of various solar water heating
systems. Certification requires testing the collectors under the
OG-lOO standard and testing the entire system. (Note that
some collectors are integrated with the storage tank, such as
integral collector and storage and thermosyphon systems, and
are listed only in the OG-300 catalog.) Before a system can be
certified, a design and installation review, and a performance
computation must be completed.
home power 125 /june & july 2008
Courtesy
certified solar
SRCC's OG-300 Certification Process
SRCC OG-IOO:
OG-300
Collector test
Design and Installation
Guidelines Review:
Drawings,
^ T
installation manual.
System Test
component labels
TRNSYS
Computer Modeling:
Performance computation
Certification:
Rating label
Collectors and systems are tested under standard
laboratory conditions that are certain to be different from
those at your home. Testing is a combination of durability
and performance, with the test procedures for performance
specified by the American Society of Heating, Refrigerating,
and Air-Conditioning Engineers (ASHRAE Standard 93,
"Methods of Testing to Determine the Thermal Performance
of Solar Collectors").
What’s Your Climate?
Before you select a system, you'll need to classify your climate
area as either "mild" or "harsh." For the purposes of the table
(see page 96), we split the list according to each system's
freeze tolerance — or lack of it — and set the dividing line at
10°F.
However, since water freezes under different conditions
of temperature, pipe size, liquid flow, insulation, and time,
there are no hard-and-fast divisions — it's very difficult to give
a rule that will work everywhere under all conditions.
In "mild" climates, where freezing conditions are
uncommon, potable water can be used directly in the collector
loop. In SRCC lingo, this is a "Type I fluid system." These
mild-climate systems have no heat exchangers, and are usually
simpler and less expensive, with few components. However,
because of their limited freeze tolerance, these systems, which
include integrated collector storage (ICS) systems, direct
forced-circulation systems, and open-loop thermosyphon
units, are generally limited to installation in Hawaii and the
southernmost part of the United States — states that border
Mexico or the Gulf of Mexico.
The rest of the United States is classified as falling in
the "harsh" climate, since the probability of freezing is
far greater. These areas are best served with true freeze-
tolerant systems, which have heat exchangers, and are either
drainback systems that use potable water (Type I fluid
system) or nontoxic antifreeze systems (Type II fluid system).
The SRCC catalog refers to these systems as "indirect forced-
circulation systems."
Solar Hot Water System -Types Compared
System Type Climate & Description Advantages Disadvantages Installation
Integral Collector
Storage (ICS)
Passive: Open loop for
mild climates
Simplicity; lowest cost
Poor freeze protection;
poor tank insulation
Heavy units; easy
to install; can have
cosmetic-appearance
issues
Thermosyphon
Passive: Open loop for
mild climates; closed
loop can be used in
harsh climates
Simple open loop;
tank is insulated
Open loop has poor
freeze protection;
closed loop needs
a heat exchanger;
potable water lines
to collector subject to
freezing
Very heavy systems;
easy to install; can have
cosmetic-appearance
issues
Direct Pump:
Direct circulation
Open loop for mild
climates only
Simple active system;
can be PV powered
Poor freeze protection;
freeze valves can give
false security
Easy installation; needs
electrical source
Drainback:
Closed loop, forced
circulation
Closed loop for all
climates
Simple system when
compared to antifreeze
systems; limited
overheating
Needs a high-head
pump and heat
exchanger; harder to
power with PV
Slope of collectors and
piping is critical
Closed-Loop
Antifreeze:
Forced circulation
Closed loop for all
climates
Best freeze protection;
easily PV powered
Most complex; can
have overheating
problems; needs a heat
exchanger
Most difficult
installation
www.homepower.corn
certified solar
MILD CLIMATE SYSTEMS
Integral Collector Storage
Passive ICS systems (batch water heaters) are the simplest
solar water heater. Cold water flows under normal water
pressure to the bottom of the tank, and hot water is taken
off the top. Whenever there's a call for hot water, hot water
moves from the top of the solar batch heater as cold water is
pushed into the bottom. Most of the ICS units produced in
the United States today are progressive-tube-type heaters as
opposed to single-tank units. Although the storage tank(s) of
ICS systems are freeze-tolerant in normal operation, the weak
point in the system is the potable water pipes running to and
from the units. These systems are climate limited and are
included in the mild-climate listings. (For more information
on ICS systems, see HP 9 3 & HP 10 8.)
Thermosyphon
These systems position an insulated solar storage tank higher
than the collector, relying on the principle of heat rising to
move water through the system. These open-loop systems
are more climate-limited than ICS systems because the
small riser tubes in the collector are vulnerable to freezing.
However, thermosyphon systems can be configured in a
closed-loop design, using antifreeze in the collector and a
heat exchanger and potable water in the tank. Because closed-
loop thermosyphon systems have potable domestic water
lines to and from the collector, their Achilles' heel, they are
vulnerable to freezing.
The advantage of this system over the batch heater is
that solar heat is stored in a well-insulated tank, so hot water
can be used any time with lesser penalty of overnight losses.
The SRCC lists open-loop systems as "direct thermosyphon"
and closed-loops as "indirect thermosyphon." (A direct
thermosyphon system is described in detail in HP 97.)
Direct Pump
Used in tropical settings where freezing never occurs, this
is the simplest of the active systems, using a pump and a
standard tank with electrical elements teamed with a solar
thermal collector. A direct-pump system is also known as a
"direct-forced circulation" system by SRCC classifications.
In this open-loop system, the collector-loop fluid is potable
water. As with ICS and open-loop thermosyphon systems,
potable water must run outside to the collector, and the
associated plumbing is vulnerable to freezing. A weaker freeze
link is the smaller riser tubes connected to the header tubes.
They are subject to freezing before the insulated potable water
lines. Direct-pump systems can easily be married to a PV
module that will power a DC pump. Direct forced-circulation
systems are very popular in places like Hawaii, which has
mild temperatures and plenty of sunshine.
Freeze-Protection Gizmos—
Caveat Emptor
In an attempt to have their systems reclassified to gain
more sales, some manufacturers have incorporated freeze-
protection schemes into their "mild climate" systems. The
bottom line? Buyer beware if you're considering installing
one of these systems in your "harsh" climate. Only two
designs — drainback and antifreeze systems — offer reliable
freeze protection in these areas. Here are some freeze-
protection devices that have caused collectors to freeze in the
past — and consequently have required expensive repairs or
replacement.
Direct pump with recirculation. Some differential controls
for turning pumps on and off also have a "freeze-protection
feature" that can be set to recirculate water from the storage
tank to the collector. The logic is that the warmed, stored water
can be routed to the collector to prevent it from freezing. But
this method has ruined collectors when unusually bad winter
storms move in and power outages occur. Without electricity
to power the control and pump, water can stagnate in the
collector, and a hard freeze can burst the collector riser tubes.
Freeze valves (a.k.a. dribble valves). For freeze protection,
some direct-pump, ICS, and thermosyphon systems use a
freeze valve, a passive valve that is set to open at a low
temperature (either 35°F or 45°F). When the valve opens,
water from the municipal or well system enters the collector,
and the near-freezing water in the collector dribbles from the
valve onto the roof or the ground. Although this strategy is
perhaps more reliable than recirculation systems, it is far from
fail-safe. Hard (mineral-laden) water can eventually clog the
valve, and poof! — the supposed freeze protection is gone.
Draindown valves, which were incorporated into direct-pump
systems all over the United States, have been one of the worst
hiccups in solar-thermal history. At a preset, low temperature,
a controller activated the valves to divert water in the collectors
to drain outside. However, like freeze valves, draindown valves
were prone to failure due to corrosion, hard-water deposits,
and clogging. Typically, the first winter freeze ruined the
collector — when the valve failed, the collectors remained full
of water and froze.
home power 125 /June & july 2008
certified solar
HARSH CLIMATE SYSTEMS
Drainback
These indirect forced-circulation systems are reliable,
freeze tolerant, and fairly easy to install. The closed-loop
drainback system requires perhaps the least amount of
maintenance of any indirect, active system. The heat-
transfer fluid is distilled water, which seldom has to
be changed. When the system is not pumping, the
solar collector is empty with the water having drained
to the reservoir tank, usually located just above the
solar storage tank. Higher-capacity reservoir tanks are
typically required in large systems. The system relies on
the collectors and piping being drained when freezing
conditions are possible. Both are sloped toward the
drainback tank so that when the pump turns off, the water
in the collector loop passively drains back into the tank.
Since the pump must have enough power to push
water from the drainback-tank fluid level to the top of
the collectors — a distance that can be 20 or 30 feet — most
installations require a high-head pump. Because of the head
requirements and the limited choices in DC pumps, drainback
systems are tougher to adapt to direct PV power. (Drainback
systems are featured in HP 8 6 & HP 97.)
Antifreeze
This is the most complex indirect forced-circulation, closed-
loop system — and therefore the most difficult to install. It also
is the system with the best freeze protection, and as such, is
popular in northern climates.
In this active, closed-loop system, incoming potable
water is routed to the solar storage tank, but never into the
collectors. A water-antifreeze mixture circulates from the
collectors through a heat exchanger and then is pumped back
through the collectors.
Antifreeze systems can overheat in the summer if there
is too much collector surface area relative to tank storage
volume. Overheating can be combated by using the 'Vacation
mode" of newer differential controls, which will allow
fluid to circulate through the system at night, cooling the
fluid. PV-powered systems can incorporate a bypass valve
around the check valve, which will allow the system to
reverse thermosyphon at night to cool the antifreeze. (See
Bob Inouye's article in HP123 for details of a bypass valve.
Antifreeze systems were covered in depth in HP85 & HP95.)
For a good overview of the five systems mentioned here, see
"Solar Hot Water: Simplified" in HP107.
Basic Open-Loop
System
Cold to Collector:
Potable water in
collector loop
Solar Thermal
Collector
Hot from
Collector
Basic Closed-Loop
System
Cold to Collector:
Antifreeze in
collector loop
Solar Thermal
Collector
Hot from
Collector
Hot Out:
Potable to house
or backup heater
Note: Pumps and other
components not shown
Heat Exchanger:
External (shown) or
internal;Transfers heat
without mixing fluids
Cold Supply In:
Potable
Hot Out:
Potable to house
or backup heater
Note: Pumps and
other components
not shown
www.homepower.corn
MILD CLIMATE SYSTEMS
certified solar
TABLE SPECS
Freeze-Tolerant Temperature — The temperature at which
manufacturers estimate some part of the system is vulner-
able to freezing. The SRCC says that " unless a system is
installed in a nonfreezing climate, every system must have
an automatic mechanism to at least partially protect it
from freezing (i.e., automatic draining, antifreeze fluids, or
thermal mass)."
Collector Size — The collector size for a given system is
determined by the storage-tank volume and the amount
of sunlight available at the installation site. The size of the
collector is important: It must be large enough to do the job but
not so big that it is a waste of money or causes overheating.
Storage Tank Size — System sizing is normally based on a
one-day recovery time, which means that the storage tank
should be large enough to satisfy the demands of a household
for one day, at a minimum.
Annual KWH Saved — The SRCC catalog boils performance
data down to savings estimates — given in annual estimated
KWH — in several cities. We chose San Diego; Richmond,
Virginia; and Seattle to represent sunny, partly cloudy, and
cloudy climate conditions, respectively. The SRCC has modeled
Manufacturer
Freeze Tolerant
Temp. (°F)
Collector Size Storage Tank Size
(Sq. Ft.) (Gal.)
Annual KWH Saved
San Diego, CA
Richmond, VA
Seattle, WA
ACR Solar Inti.
30 °
40.1
50
2,600
2,100
1,700
Energy Laboratories
Inc.
22 °
30.8
68
2,500
2,100
1,600
Heliodyne Inc.
27 °
53.5
80
3,600
3,200
2,600
27 °
64.5
120
3,700
3,300
2,700
27 °
64.5
80
3,600
2,900
2,400
27 °
80.3
120
3,500
3,400
2,900
27 °
80.3
120
3,800
3,500
2,900
27 °
96.7
120
3,700
3,100
2,500
27 °
120.4
120
3,500
3,400
3,000
Integrated Solar LLC
20 °
25.0
40
1,500
1,200
1,000
20 °
33.2
50
1,900
1,600
1,300
Rheem Water Heaters
19 °
42.7
77
2,200
1,600
900
19 °
85.4
113
3,300
2,500
1,600
19 °
85.4
113
3,300
2,500
1,600
19 °
64.0
77
3,000
2,600
2,100
19 °
85.4
113
3,200
2,800
2,200
19 °
85.4
113
3,200
2,800
2,300
41 °
64.0
90
3,500
2,700
2,200
41 °
64.0
114
3,600
2,700
2,200
Solnhnrt Industries
Solene
20 °
64.0
120
3,500
3,100
2,500
20 °
80.1
120
3,700
3,600
3,000
20 °
60.6
80
3,800
3,500
2,800
20 °
80.1
120
3,900
3,900
3,100
20 °
77.7
120
3,700
3,500
2,900
20 °
63.6
120
3,800
3,600
2,800
20 °
77.7
120
3,800
3,800
3,000
SunEarth Inc.
20 °
39.7
64
2,400
2,000
1,700
20 °
49.8
84
2,600
2,200
1,800
41 °
40.9
80
3,000
2,500
2,000
41 °
40.9
80
3,100
2,600
2,000
15 °
73.9
116
3,000
2,600
2,100
15 °
81.7
116
3,300
2,800
2,300
15 °
65.7
80
3,000
2,500
2,000
10 °
32.1
40
2,200
1,900
1,500
10 °
32.1
50
2,300
1,900
1,500
Thermal Conversion
Technology Inc.
home power 125 /june & july 2008
certified solar
the systems data for many other cities in the United States and
also provides listings on systems with gas backup, which are
not included in our condensed table.
System Type — The catalog lists the systems by four types:
integral collector storage (ICS, a.k.a. batch water heater);
thermosyphon systems (open and closed loop); forced-
circulation systems (direct pump, drainback, and antifreeze);
and self-pumping systems. (Note: There are no self-pumping
systems currently certified.)
Controller — Found only in forced-circulation (active) systems,
controllers energize the system pump at the appropriate time.
There are differential controllers, systems without controllers,
and systems that use a PV module to automatically turn on
the pump when the sun shines.
Fluid Used — Only two types of fluids, water (Type I fluid)
and nontoxic propylene glycol antifreeze (Type II) mixed
with water, are used in modern SHW systems.
Heat Exchanger — Transfers the energy collected by the
collector-loop fluid to the domestic water used in the
home. The type and size of heat exchanger can influence
the system efficiency significantly. (For more info, see
HP92.)
System Name
System Model
System Type
Collector Model
Aux. Tank
Size (Gal.)
Fluid
Controller
Supply-Side
Heat Exchanger
Skyline System 3
200132C502TE
Direct Forced
Circulation
ACR Solar 20-01
50
Water
PV Panel
Controller
None
Roof Integrated
Thermosyphon
RITH 72 E
Direct
Thermosyphon
Energy Lab. RITH-72
50
Water
None
None
HF 23366 G 80 AC S E
Heliodyne - 336 000
HF 2408 G 120 AC S E
Heliodyne - 408 000
None
HF 2408 G 80 AC S E
Direct Forced
Circulation
Heliodyne - 408 000
Differential
Controller
Helio-Flo
HF 2410 G 120 AC D E
Heliodyne - 410 000
50
Water
None
HF 2410 G 120 AC S E
Heliodyne - 410 000
None
HF 3408 G 120 AC S E
Heliodyne - 408 000
HF 3410 G 120 AC D E
Heliodyne - 410 000
50
Sun Systems - CS 340
50
Sun Systems - CS 450
50
CopperSun
CS340SV-E
CS450-E
Direct Integral
Collector Storage
Water
None
None
Indirect
Thermosyphon
Mantle Heat
Rheem Solaraide
RS80-42BP
Rheem - RS21-BP
None
Glycol
None
Exchanger with
a Single Wall
Glycol
None
Mantle Heat
Exchanger with
a Single Wall
Water
Differential
Controller
None
Solahart
Streamline Electric
444BCXII
444KF & 444KF Free Heat
ASE 303BCXII
ASE 444BCXII
ASE 444KF & ASE 444KF
Free Heat
340SL-3Bt
430SL-3Bt
Indirect
Thermosyphon
Direct Forced
Circulation
Solahart - KF
Solahart - Bt
None
Solene/Chromagen
SLCR64DC-80
Solene - SLCR-32
Differential
DC Open Loop
SLCR80DC-120
Solene - SLCR-40
Controller
Solene/Chromagen
SLCR60PV-80
Solene - SLCR-30
PV Panel
PV Open Loop
SLCR80PV-120
Direct Forced
Solene - SLCR-40
None
Water
Controller
None
Solene/Corona DC
Open Loop
SLC080DC-120
Circulation
Solene - SLCO-40
Differential
Controller
Solene/Corona PV
SLCO64PV-120
Solene - SLCO-32
PV Panel
Open Loop
SLC080PV-120
Solene - SLCO-40
Controller
CopperHeart
CP-60P
Direct Integral
Collector Storage
SunEarth - CP-30
50
CP-80P
SunEarth - CP-40
50
SunSaver
NF40P-80S
Direct Forced
Circulation
SunEarth - EP-40
None
NF40P-80T
SunEarth - EP-40
SunSiphon
EPGX1 16-63-2
Indirect
Thermosyphon
SunEarth - EP-24
50
EPGX1 16-80-2
SunEarth - EP-40
50
EPGX80-64-2
SunEarth - EP-32
50
Water
None
Differential
Controller
None
Glycol
None
Mantle Heat
Exchanger with a
Single Wall
TCT - PT-40-CN
50
TCT - PT-50-CN
50
ProgressivTube
PT-40-CN
PT-50-CN
Direct Integral
Collector Storage
Water
None
None
www.homepower.corn
MILD CLIMATE SYSTEMS
HARSH CLIMATE SYSTEMS
certified solar
Manufacturer
Freeze Tolerant
Collector Size
Storage Tank Size
Annual KWH Saved
Temp. (°F)
(Sq. Ft.)
(Gal.)
San Diego, CA
Richmond, VA
Seattle, WA
ACR Solar Inti.
-54°
40.1
80
2,300
1,900
1,600
-54°
40.1
80
2,200
1,800
1,500
Alternate Energy
Technologies
-20°
98.0
120
3,200
3,000
2,400
-20°
63.8
120
3,300
3,100
2,500
-20°
65.3
120
3,300
3,100
2,500
-20°
79.6
120
3,400
3,300
2,700
-20°
63.8
80
3,300
3,000
2,400
-20°
65.3
80
3,300
3,000
2,400
-20°
79.6
80
3,400
3,200
2,600
BFT Ltd.
-50°
33.1
65
1,500
1,300
1,100
-50°
66.2
80
2,400
2,000
1,700
Bobcat & Sun Inc.
-60°
64.5
80
2,800
2,500
2,000
-60°
64.5
80
3,000
2,700
2,200
-60°
64.6
80
2,900
2,600
2,100
-60°
65.7
80
2,900
2,600
2,100
Butler Sun Solutions
-54°
40.9
80
2,400
2,000
1,600
-54°
40.9
80
2,500
2,000
1,500
-54°
40.9
80
2,500
2,000
1,500
Enerworks Inc.
-50°
61.9
80
3,000
2,700
2,200
-50°
92.8
120
2,700
2,500
2,200
Fafco Inc.
-20°
47.4
50
1,800
1,500
1,300
-20°
47.4
80
1,900
1,600
1,300
-20°
94.9
50
2,200
1,800
1,500
-20°
94.9
80
2,300
2,000
1,600
Heat Transfer
Products
-60°
43.6
80
NA
NA
NA
Heliodyne Inc.
-60°
53.5
80
3,200
2,800
2,200
-60°
64.5
120
3,300
3,000
2,300
-60°
80.3
120
3,500
3,200
2,600
-60°
53.5
80
3,400
2,800
2,200
-60°
80.3
120
3,600
3,200
2,600
-60°
80.3
120
3,600
3,200
2,500
-60°
96.7
120
3,700
3,400
2,700
Integrated Solar LLC
-60°
79.8
120
3,000
2,500
1,900
-60°
39.9
65
2,200
1,800
1,400
-60°
39.9
80
2,700
2,300
1,800
Morley
Manufacturing
-60°
39.9
60
2,500
2,000
1,600
-60°
40.1
60
2,500
2,000
1,600
-60°
40.9
60
2,500
2,000
1,600
Mr. Sun Solar
-50°
39.8
80
2,900
2,500
2,000
-50°
55.7
80
3,400
3,000
2,400
home power 125 /june & July 2008
certified solar
System Name
System Model
System Type
Collector Model
Aux. Tank
Size (Gal.)
Fluid
Controller
Supply-Side
Heat Exchanger
Skyline System 5
200152C80EX
Direct Forced
ACR Solar 20-01
None
Glycol
PV Panel
Tank Wraparound
Heat Exchanger
with Double Wall
and Positive Leak
Detection
200152C80EX2TE
Circulation
ACR Solar 20-01
50
Controller
EagleSun
DB-120-96
MSC-32
Tank Wraparound
Heat Exchanger with
a Single Wall
DX-1 20-64
Indirect Forced
Circulation -
Drainback
AE-32
DX-1 20-64
MSC-32
None
Water
Differential
EagleSun DX
DX-1 20-80
AE-40
Controller
Immersed Coil Heat
Exchanger with a
Single Wall
DX-80-64
AE-32
DX-80-64
MSC-32
DX-80-80
AE-40
BFT - SP-20
50
BFT - SP-20
50
Solar Patriot
SP20-1-65G-PV-E
SP20-2-80G-PV-E
Indirect Forced
Circulation -
Antifreeze
Glycol
PV Panel
Controller
Immersed Coil Heat
Exchanger with
a Double Wall
Heliodyne - 408 000
None
Heliodyne - 408 000
None
Radco - 408P-HP
None
SunEarth - EP-32
None
Sun-Pak
SP64CHE
SP64CHE-1
SP64PHE-1
SP64PHE-1
Indirect Forced
Circulation -
Antifreeze
Glycol
Differential
Controller
Tank Wraparound
Heat Exchanger
with Double Wall
and Positive Leak
Detection
BSS-PV1-80E2b
Indirect Forced
Circulation -
Antifreeze
SunEarth - SC-40
50
PV Panel
Immersed Coil
Solar Butler
BSS-PV1-80Ea
SunEarth - SC-40
Glycol
Controller
Heat Exchanger
with a Double Wall
and Positive Leak
Detection
BSS-S1-80Ea
SunEarth - SC-40
None
Differential
Controller
Solar Water
Heating Appliance
EWRA2-E80
EWRA3-E120
Indirect Forced
Circulation -
Antifreeze
Enerworks - COL-4x8-TL-
SG1-SD10US
50
Enerworks - COL-4x8-TL-
SG1-SD10US
50
Glycol
Differential
Controller
Plate Heat Exchanger
with a Single Wall
VDB-48U-50E-50S
50
Polymer Drainback
VDB-48U-50E-80S
Indirect Forced
Circulation -
Drainback
Fafco - Revolution
50
Water
Differential
Plate Heat Exchanger
VDB-48UX2-50E-50S
50
Controller
with a Single Wall
VDB-48UX2-50E-80S
50
SuperStor
Contender Solar
SSC-80SE
Indirect Forced
Circulation -
Antifreeze
Apricus - AP-30
None
Glycol
Differential
Controller
Immersed Coil Heat
Exchanger with
a Single Wall
16 DWCL HP 2 3366 G
80 ACS
Heliodyne - 336 000
Heliopak
16 DWCL HP 2 408 G
120 ACS
Heliodyne - 408 000
Differential
Controller
16 DWCL HP 2 410 G
120 ACS
Indirect Forced
Circulation -
Antifreeze
Heliodyne - 410 000
Shell-and-Tube
Heat Exchanger
with a Double Wall
and Positive Leak
Detection
HP HX SS 2 3366 G PV
80 EES
Heliodyne - 336 000
None
Glycol
Helio-Pak Helix
HP HX SS 2 410 G PV
120 SE S
Heliodyne - 410 000
PV Panel
SS PV
HP HX SS 3 3366 G PV
120 SE S
Heliodyne - 336 000
Controller
HP HX SS 3 408 G PV
120 SE S
Heliodyne - 408 000
RadCo Drainback
Heat Exchanger
R-DBHX-8-120S-80P
Indirect Forced
Radco - 410P-HP
Differential
Controller
Immersed Coil Heat
R-DBHX-8-65S-40P
Circulation -
Radco - 410P-HP
None
Water
Exchanger with
R-DBHX-8-80S-40C
Drainback
Radco -410C-HP
a Single Wall
High Sierra
Drainback
HS60B/40
HS60B/40
HS60B/40
Indirect Forced
Circulation -
Drainback
Radco -410P-HP
50
Heliodyne - 410 000
50
SunEarth - EC-40
50
Water
Differential
Controller
Shell-and-Tube Heat
Exchanger with
a Single Wall
AE-40
50
AE-56
50
Sol-Reliant
SR 40/80 E PVDB
SR 56/80 E PVDB
Indirect Forced
Circulation -
Antifreeze
Glycol
PV Panel
Controller
Tank Wraparound
Heat Exchanger
with a Double Wall
and Positive Leak
Detection
www.homepower.corn
HARSH CLIMATE SYSTEMS
HARSH CLIMATE SYSTEMS
certified solar
Manufacturer
Freeze Tolerant
Collector Size
Storage Tank Size
Annual KWH Saved
Temp. (°F)
(Sq. Ft.)
(Gal.)
San Diego, CA
Richmond, VA
Seattle, WA
-40°
58.1
80
3,000
2,700
2,200
Schuco USA L.P.
-40°
87.1
120
3,300
3,100
2,500
-40°
49.7
80
2,900
2,500
2,100
-40°
74.6
120
3,300
3,000
2,400
Solar Energy Inc.
-20°
115.7
120
3,400
3,100
2,500
-20°
119.4
120
3,400
3,100
2,500
-20°
95.7
120
3,300
3,000
2,300
-20°
98.5
120
3,300
3,000
2,300
-20°
65.6
80
3,100
2,700
2,200
-20°
77.1
80
3,200
2,900
2,300
-20°
79.6
80
3,200
2,900
2,300
Solarhot
-10°
64.0
80
3,400
3,200
2,600
-10°
64.5
80
3,400
3,200
2,600
Solene
-10°
60.6
80
3,200
2,900
2,300
-10°
64.0
80
3,300
2,900
2,400
-10°
63.6
80
3,200
2,800
2,300
-10°
77.7
80
3,400
3,000
2,500
-10°
77.7
80
3,200
2,900
2,300
-10°
63.6
80
3,200
2,800
2,300
-10°
77.7
80
3,400
3,000
2,500
Stitt Energy
Systems Inc.
-40°
79.6
120
3,100
2,600
2,100
-40°
39.8
80
2,300
1,900
1,600
SunEarth Inc.
-50°
65.7
80
3,200
2,900
2,400
-60°
65.7
80
3,500
3,200
2,600
-60°
65.7
80
3,500
3,000
2,400
-60°
65.7
80
3,400
3,100
2,500
-60°
81.7
120
3,600
3,400
2,800
-60°
81.7
120
3,400
3,300
2,700
-60°
81.7
120
3,700
3,300
2,600
-60°
81.7
120
3,600
3,300
2,700
Synergy Solar
-50°
39.6
80
2,700
2,200
1,800
-50°
53.4
80
3,100
2,600
2,100
-50°
53.4
80
3,000
2,600
2,100
-50°
59.4
80
3,000
2,700
2,200
-50°
53.4
80
2,700
2,300
1,900
Thermomax
Industries Ltd
-60°
65.9
80
3,200
2,900
2,300
-60°
82.2
120
3,400
3,100
2,500
-60°
98.6
120
3,500
3,400
2,700
-50°
92.1
120
3,400
3,100
2,500
-50°
92.1
80
3,400
3,100
2,500
-50°
107.4
120
3,500
3,300
2,600
Trendsetter
Industries
-20°
81.7
120
2,800
2,500
2,100
lOO
home power 125 /june & july 2008
certified solar
System Name
System Model
System Type
Collector Model
Aux. Tank
Size (Gal.)
Fluid
Controller
Supply-Side
Heat Exchanger
Premium Package
Premium II-80E
Schuco - V, H, LA
Tank Wraparound
Premium III-120E
Indirect Forced
Circulation -
Antifreeze
Schuco - V, H, LA
None
Glycol
Differential
Heat Exchanger
with a Double Wall
and Positive Leak
Slimline Package
Slimline II-80E
Schuco - V, LA
Controller
Slimline III-120E
Schuco - V, LA
Detection
D2B-12009120
Solar Energy - SE-40
D2B-12009120
Alternate Energy Tech.
- AE-40
Shell-and-Tube Heat
Duro-Drainback
D2B-12009-96
Indirect Forced
Alternate Energy Tech.
- AE-32
Differential
Controller
Exchanger
Solar Water Heating
System
D2B-12009-96
Circulation -
Drainback
SunEarth - EP-32
None
Water
D2B-8009-63
Solar Energy - SE-21
D2B-8009-80
Solar Energy - SE-40
Tank Wraparound
D2B-8009-80
Alternate Energy Tech.
- AE-40
Heat Exchanger
Solvelox DB
S-SV-DB100
Indirect Forced
Circulation -
Drainback
Solene - SLCR-32
None
Water
Differential
Controller
Plate Heat Exchanger
with a Single Wall
S-SV-DB100
Heliodyne - 408 000
Solene/Chromagen
DC Closed Loop
SLCR60DC-80HE
Indirect Forced
Circulation -
Antifreeze
Solene - SLCR-30
None
Glycol
Differential
Controller
Tank Wraparound
Heat Exchanger
with a Double Wall
and Positive Leak
Detection
SLCR64DC-80HE
Solene - SLCR-32
Solene/Corona DC
Closed Loop
SLCO64DC-80HE
Indirect Forced
Circulation -
Drainback
Solene - SLCO-32
Water
SLC080DC-80HE
Solene - SLCO-40
SLC080DC-80HE-XE
Solene - SLCO-40
50
Solene/Corona
Drainback
SLCO64DC-80DB
Solene - SLCO-32
None
SLC080DC-80DB
Solene - SLCO-40
Sup.plen.ergy Solar
Water Heater
SESI-120-80
SESI-80-40
Indirect Forced
Circulation -
Antifreeze
Alternate Energy Tech.
- AE-40
Alternate Energy Tech.
- AE-40
None
Glycol
PV Panel
Controller
Tank Wraparound
Heat Exchanger with
a Double Wall
Cascade
ECRD-64-80
Indirect Forced
Circulation -
Drainback
SunEarth - EC-32
None
Water
Differential
Controller
Solaray
TE64C-80-1
Indirect Forced
Circulation -
Antifreeze
SunEarth - EC-32
Glycol
TE64C-80-PV
SunEarth - EC-32
PV Panel
Controller
TE64P-80-1
SunEarth - EP-32
Differential
Controller
TE80C-120-1
SunEarth - EC-40
TE80C-120-2
SunEarth - EC-40
50
TE80C-120-PV
SunEarth - EC-40
None
PV Panel
Controller
TE80P-120-1
SunEarth - EP-40
Differential
Controller
Tank Wraparound
Heat Exchanger
with a Double Wall
and Positive Leak
Detection
40-1T
Synergy - TC-19.78
None
Drainback
Stainless HX
53- IT
Indirect Forced
Synergy - TC-26.52
Differential
Controller
Plate Heat Exchanger
with a Single Wall
53-2T
Circulation -
Synergy - TC-26.52
50
Water
60-2T
Drainback
Synergy - TC-19.78
50
S53-2T
Synergy - S26.68
50
Mazdon 40-R80
Thermo Tech. -
TMA-600-20
Thermomax
Mazdon
Mazdon 50-R120
Indirect Forced
Circulation -
Antifreeze
Thermo Tech. -
TMA-600-50
Tank Wraparound
Heat Exchanger
with a Double Wall
and Positive Leak
Detection
Mazdon 60-R120
Thermo Tech. -
TMA-600-30
None
Glycol
Differential
Controller
Thermomax
Solamax
Solamax 60R-R120
Thermo Tech. - AST30
Solamax 60R-R80
Thermo Tech. - AST30
Solamax 70R-R120
Thermo Tech. - AST70
Six Rivers Solar
SRS-100-2-40-PC-E
Indirect Forced
Circulation -
Drainback
SunEarth - SP-40
50
Water
Differential
Controller
None
www.homepower.corn
101
HARSH CLIMATE SYSTEMS
certified solar
Certification for
Tax Credit Eligibility?
Unless federal tax credits for SHW systems are extended,
this may be the last year you can take advantage of
Uncle Sam by installing a solar hot water system. Under
the existing federal tax credit law, owners of new SHW
installations are eligible for a tax credit of up to $2,000.
But when it comes to what kind of certification is required
to receive a break from the Feds, the waters are muddy.
The law states that "the property" of residential solar
water heaters must be certified by the SRCC, but it's
unclear whether this refers to the collector or the whole
system.
While we aren't aware of anyone being denied the
federal tax credit from basing their claim on the OG-100
standard, some states and utility districts are requiring
OG-300 ratingsto be eligiblefortheir incentives, including
Arizona; California — Sacramento Municipal Utility District
and City of Thousand Oaks; Colorado; Illinois; Nevada —
Public Utilities Commission; and Oregon — Eugene Water
and Electric Board and the City of Ashland.
System Selection Considerations
Once you've classified your climate, you can determine
what system is right for your site. What's best? If you live
in a freezing climate — or in a milder climate but just want to
hedge your bets, use a drainback or antifreeze closed-loop
system. If it doesn't freeze, or freezes are rare and mild, one
of three "mild-climate" systems can fit your needs. Passive
or active, PV or AC powered, these choices are up to you.
Systems with quality components should have decades of
good performance.
Access
Contributing editor Chuck Marken (chuck.marken@homepower.com)
is a New Mexico-licensed plumber, electrician, and heating and air
conditioning contractor. He has been installing and servicing solar
thermal systems since 1979. Chuck is a part-time instructor for Solar
Energy International and the University of New Mexico.
Home Power Data Manager Doug Puffer (doug.puffer@homepower.
com) holds a master's degree in Environmental Studies from Clark
University and an associate's degree in software engineering. He has
installed solar hot water systems and worked in other areas of the RE
industry.
Solar Rating & Certification Corp. • www.solar-rating.org
HaRruess the
PQUUtM
www. u om
|>h SOD-6 9 5-0 5 A 5
U S Ropery offers lh& perfecf s-olufion for off of
your ollcrn ci rive energy sforogc requirement.
^ EXTREME CAPACITY
v EXTREME LIFE
c EXTREME POWER
home power 125 /june & july 2008
© f % p p @ r
1 1 ^ \i W7 1 1
r
N
^ *
■F
Modified Sine Wave
Inverters
Light Duty
Pure Sine Wave
Inverters
Samlex America Power Conversion Solutions are available through:
Commercial Grade
Pure Sine Wave
Inverters
EKXTER3
Muti Stage
Battery Chargers
StepUp/Step Down
DC-DC Converters
NEW BATTERY MONITOR
Uk
rn
i t - h k <> i ■
www.samlexamerica.com
Get Solar Access and Shading Data On-Site
with the Touch of a Button.
The Solmetric SunEye™
is all you need.
• Integrated fish-eye lens and digital camera
• Captures image of obstructions and
superimposes sunpaths
• Works anywhere in the world
• Accounts for panel tilt and orientation
• Simulates removal of shade-causing obstructions
• Generates reports and archives data
To purchase, contact 1-800-967-6917
or www.dcpower-systems.com
Solmetric
w.solmetric.com
GPS Add-on:
• Automatically detects location for each Skyline
• Compatible with new and existing SunEye units
m
Energy Efficient.
B Jmi a
Available in 1 2/24V DC or new 1 20V AC
FEATURES:
3 [F^aaajoa^
5
www.homepower.corn
'a WA Wa
FEATURING:
tpCI i h [j !]rHTiT&i
Serving the Solar Industry Since 1 979
Also Featuring:
SUN AIRE
Liquid Collectors
for Solar Hot Water
& Radiant Floor Systems
Other Solar H 2 0
Products & Parts
• Pumps
• Heat Exchangers
• Storage Tanks
• Complete Systems
• Controls
• Batch Water Heaters
d i Ft-Ti-n-
Air Collectors
for Home Heating
Other Solar Hot Air
Products & Parts
• Blowers
• Backdraft Dampers
• Controls
• DIY Systems
l BOO | 345-0311 • www.aaasalar.cam • salarstuff@aaasalar.cam
2021 ZearingNW, Albuquerque, NM8701 4
ELECTRO AUTOMOTIVE
Electric Car Conversions Since 1979
Books Videos ^=^Kits Components
Catalog Send $6.00 for our catalog, or visit our web site.
"Convert It" We wrote the book on electric car conversions - literally!
Send $30.00 postage paid for this hands-on how-to conversion manual,
written in plain English for the home hobbyist mechanic.
Conversion Kits Complete custom bolt-in kits for the VW Rabbit
and Porsche 914, or a universal kit for other small cars and light trucks.
Web Site Visit our web site for our complete catalog, price list,
gallery of conversions, and extensive conversion information section.
P.0 Box 1113-HP, Felton, CA 95018-1113 -=<^>^831-429-1989
WWW.ELECTROAUTO.COM -<^n>^ELECTRO@CRUZIO.COM
104
home power 125 /june & july 2008
www.homepower.corn
Not
to Fuse?
by John Wiles
Sponsored by the U.S. Department of Energy
Most people agree that the National Electrical Code (NEC)
improves with each edition. However, photovoltaic technology
is still evolving, with new equipment, new wiring procedures,
and new installation requirements being developed constantly.
With these changes, and more inspectors and installers coming
into the field every day, questions are bound to arise.
Some procedures and best approaches continue to stump
both old timers and newcomers alike. The question of when
to use overcurrent devices, such as fuses or circuit breakers,
in direct-current circuits between PV modules and utility-
interactive inverters is one in particular that plagues PV pros,
since the solution is not directly found in the NEC but must
be evaluated on a case-by-case basis.
Before answering this question, we first should address
the issue that properly rated fuses and circuit breakers are
functionally equivalent for this application, and are collectively
known as overcurrent protective devices (OCPDs). This is
true even though the required label on the back of certified/
listed PV modules says "fuse."
In general, PV arrays operating at DC voltages above
150 volts (cold-weather, open-circuit voltage) may use fuses,
and those operating below this voltage may use either fuses
or circuit breakers. These applications are due to the ratings,
availability, and cost of the different devices.
Protecting the Conductor
The NEC requires that, in most electrical systems, every
ungrounded circuit conductor be protected from overcurrent
that might damage that conductor. OCPDs provide that
function. However, smaller utility-interactive PV systems
may not need OCPDs in the DC circuits connected to the PV
modules.
PV modules are current-limited devices, and their
worst-case, continuous outputs, according to NEC Section
690.8(A)(1), are 1.25 times the rated short-circuit current
(Isc). An exception in Section 690.9(A) allows conductors
(typically rated at 1.56 times Isc) to be used with no OCPD
where there are no sources of external currents that might
damage that conductor.
However, if there are external sources of current that
can potentially damage the internal module conductors.
Underwriters Laboratories (UL), in its safety standard for
modules (UL Standard 1703), has established that modules
must have an external series OCPD. The NEC outlines
^ WARNING
r, * a *
u mf h' r ■ ■ * "■*
1 *v-n. LLLv IL
CO NOT TOUfr TEBM4L5.
* n
■ — mmm mm
ce ED
mu
kcso
m HD.
0065100*92
DATE 1
2000.6
iFPWAKf 1
WO ttU
TFj^BUTlHE
Ml 1 E
p C
^TT.h
AT 4 C
iw.tn mr
eow
se w
VTMx
16 . sv
15,2 V
7 d
4. 73A
3,33 A
ITc-t
at, sv
- - -
_ a, 0 kol
IH
4, 97ft
- - -
FIELD VIRIW
uimii 1 1 -■
*f I. JF|| FJi || I
rinr flAT i mg.
eg KyncERa
Hbdf r iirib
mm iM'ituiiiniw
This PV module label states the maximum series fuse size.
protection for the wire, while the UL standard addresses
protecting the module. Without an OCPD, the module can be
damaged if reverse currents are forced through the module
(due to an external or internal fault) in excess of the values of
the maximum series fuse marked on the label on the back of
the module.
External sources of current vary from system to system.
They can originate from modules or module strings paralleled
to the module of interest; from batteries backfeeding through
charge controllers; or from utility currents backfeeding
through utility-interactive inverters. (Note that the scenarios
discussed below apply only to batteryless, utility-interactive
PV systems.)
106
home power 125 /June & july 2008
code corner
Utility- Interactive Inverters &
Utility Backfeed Currents
Most smaller utility-interactive inverters (10 KW or less)
are designed so that they cannot backfeed current from the
utility into array faults. These inverters have a maximum
utility backfeed current of 0 amps. Although tests for
abnormal operation and backfeeding exist, these tests do
not rule out possible backfeed during an inverter's normal
operation. Certification, usually in the form of a technical
bulletin or technical specifications from the manufacturer,
that the inverter cannot backfeed into an array fault under
normal operation should be obtained from the inverter's
manufacturer.
If the inverter can backfeed utility currents into the DC
PV wiring, the NEC requires that an OCPD be installed in
series with the output of all strings (or modules) to protect the
cables and the modules from reverse currents. Inverters that
have a maximum utility backfeed of something other than
0 A may be inverters larger than 10 KW or those designed for
transformerless or bipolar operation. In cases where there are
fused combiner boxes mounted at the array, an OCPD may
also be needed at the inverter input, since the inverter can
be a potential source of overcurrent. This OCPD will have a
minimum rating based on the number of strings connected
in parallel on that circuit and the short-circuit current of
each string. This OCPD is sized to allow maximum forward
currents from the array (all strings of modules) to pass
through without interruption and to keep the overcurrent
device from operating at more than 80% of rating.
Faults & Parallel Strings
The most common backfeed situation occurs in systems where
there are multiple strings of modules connected in parallel. In
the event of a fault, nonfaulted strings may be able to supply
sufficient overcurrents (through the parallel connection) to
damage either the conductors or the modules in the faulted
strings. The inverter, for this example, has not contributed to
the fault currents.
Fault currents can increase the normal current being
carried in wires and modules. So the basic question becomes:
How many PV modules or strings of modules can be
connected in parallel and still meet NEC and UL requirements
(marked on the back of each module) before an OCPD is
needed on each module or string of modules?
UL requirements marked on the modules are based on the
reverse-current tests described, which stipulate a maximum
value for the OCPD. Section 110.3B of the NEC requires that
installers follow the manufacturer's instructions and labels.
However, lesser values can be used as long as they meet the
NEC requirement of being 1.56 times the module short-circuit
current (1.56 Isc) to protect the conductor associated with the
module or string of modules (Section 690. 8 A and B).
In a few cases, module manufacturers have not met
the code requirements, and the value of the module OCPD
marked on the back of the module is less than 1.56 Isc. This
poses a code conflict (110.3(B) vs. 690.8,9) and is an issue for
UL to rectify.
www. homepower . com
107
corner
String Scenarios
Assuming batteryless grid-intertie with an inverter that is
certified not to backfeed via the AC source, let's examine
some scenarios.
One string of modules. In a one-string system, no fusing
would be required because no external sources of overcurrent
exist. An unfused DC PV disconnect would be used on
this type of system. The maximum series fuse rating that is
marked on the back of the module is at least 1.56 Isc, and
there are no sources of external currents that could damage
the modules or the connecting cables (also rated at 1.56 Isc
or higher).
Now let's look at a PV system with multiple strings of
modules connected in parallel. Keep in mind that we are not
determining the rating of any required OCPD; we are merely
making some calculations that determine whether or not an
OCPD is needed on each string of modules.
Two strings in parallel. Consider two modules or two
strings of modules connected in parallel, then connected to the
inverter input. Each string of modules can generate a maximum
of 1.25 Isc. If a fault occurs in one string, the second unfaulted
string can try to force 1.25 Isc amps into the faulted string.
However, the modules in the faulted string can withstand
currents up to at least 1.56 Isc or higher (if their marked series
fuse rating is higher), and the conductors have an ampacity of
at least 1.56 Isc or greater. Therefore, with only two strings of
modules, no currents exist in the PV array that can damage the
modules or the wiring — and no OCPDs are required.
Three strings in parallel. Now consider a system with
three strings of modules connected in parallel. A fault in one
string could see currents from the two other unfaulted strings.
Each of these unfaulted strings could deliver up to 1.25 Isc
under worst-case conditions for a total of 2.5 Isc (2 x 1.25 Isc).
Suppose that the module manufacturer had the value of the
maximum series fuse marked on the back of the module of
exactly 1.56 Isc and the wiring was sized at exactly 1.56 Isc.
The currents from the two unfaulted strings at 2.5 Isc would
be far greater than the series fuse rating of the module and
the ampacity of the conductors, risking damage. In this case,
fuses in all three strings at a minimum value of 1.56 Isc would
be required.
However, module manufacturers usually do not specify
a marked maximum fuse value of exactly 1.56 Isc. Typically,
the module will pass the UL reverse-current tests at a higher
current, such as 15 amps. As an example, let's take a module
that has an Isc of 5 amps and a marked value of the maximum
series fuse of 15 amps. To protect the conductors, the
interconnecting conductors between the modules must also
have an ampacity of 15 amps, after the appropriate derating
for conditions of use have been applied. In a system with
three series strings of this module, the two unfaulted strings
could deliver 12.5 amps (2 x 1.25 x 5). Since this current is less
than the 15-amp ampacity of the conductors and is also less
than the 15-amp maximum series fuse requirement marked
on the back of the module, no fuses are required because no
damage can be caused by overcurrent. The actual conductor
ampacity would not have to be 15 amps but would have to be
at least 12.5 amps after derating for conditions of use.
Determining Fuse
Requirements
In another example, let's look at a module rating of 8 amps
Isc with the module wiring and module fuse rating still at 15
amps. The two unfaulted strings could send up to 20 amps (2
x 8 x 1.25). Because this exceeds the conductor ampacity and
the ability of the module to withstand reverse currents, fuses
would be required in each string of modules. The OCPD must
be at least 1.56 Isc — in this case, 12.48 amps (1.56 x 8) and
not more than 15 amps. A 15-amp OCPD would normally be
used.
Modules with low Isc and high series fuse ratings.
Some modules have a low short-circuit current and a high
maximum series fuse rating. A module with a 1.5-amp Isc and
a 20-amp maximum series fuse can have up to 11 strings of
modules in parallel without any OCPD.
The bottom line is that when more than two modules or
strings of modules are connected in parallel, a calculation
should be done to see if an OCPD is required in each string.
When three strings of modules are connected in parallel
without fuses, the conductor ampacity may have to be greater
than the normal 1.56 Isc, as described in NEC 690.9(A),
exception (b). For a slightly more technical approach to these
requirements and calculations, see Appendix J in PV Power
Systems and the 2005 NEC: Suggested Practices manual (see
Access).
Access
John Wiles (jwiles@nmsu.edu) works at the Institute for Energy
and the Environment, which provides engineering support to the
PV industry and a focal point for code issues related to PV systems.
As an old solar pioneer, he lived for 16 years in a stand-alone PV-
powered home — permitted and inspected, of course. This work
was supported by the United States Department of Energy under
contract DE-FC 36-05-G01 5149.
Photovoltaic Power Systems and the 2005 National Electrical
Code: Suggested Practices by John Wiles • www.nmsu.edu/~tdi/
Photovoltaics/Codes-Stds/PVnecSug Pract.html
PV Systems Inspector/Installer Checklist and previous Code Corner
articles • www.nmsu.edu/~tdi/Photovoltaics/Codes-Stds/Codes-
Stds.html
home power 125 /June & july 2008
1 ^
SOLAR
an SC Solar Company
Toll-Free
866 - 856-9819
innovativesolar.com
Expert Solar Design,
Unsurpassed Customer Service
Whether you are looking for a solar system to power your entire
home, or a small system to provide back-up during a power
outage, the sales and design team at Innovative Solar Solutions
brings the experience and commitment to service that instill
confidence in our customers.
■ Solar Water Pumping Systems
■ Inverters, Charge Controllers and Batteries
■ Large Selection of Solar Panels
■ Complete Systems - Grid Tied & Off Grid Systems
2725 WESTINGHOUSE BLVD., SUITE 100, CHARLOTTE, NC 28273
H Inc. | Phone (909) 434-31 00 | www.sunearthinc.com
yfeca
With Steca's
Temperature Differential
Controllers.
TR 0301 U
■ Digital acojgQ^
■ Lighted animated^CD display
■ 3 sensor inputs / 1 ’fused
1 20 V AC output
■ Freeze recirculation functions
■ Vacation overheat protection I
yieca
Hot water
from the sun.
A&C Green Energy has been
serving the alternative energy
industry for years. In today’s
society where energy demand
is increasing, more attention
is being paid to the environment
and the value of clean energy.
We offer complete wind turbine
systems from 500 W to 20 kW
as well as solar panels.
Wind turbine systems
• Solar panels
• Site Assessment
Installation & Services f'lv.
Toll Free! 866-WNDPWR-3
or 866-963-7973 ■
PO Box 941122, Plano, TX 75074
sales@acgreenenergy.com www.acgreenenergy.com
Wind Turbine DIY Materials
j-p
Blades & Hub
Magnets
Magnet Wire
■*~ 4 *eries
CMS Magnetics has been selling commercial wind generator parts for
years. Our customers require quality, durability, and efficiency. This is
why CMS Magnetics is at the top of the small wind generator industry.
Our powerful neodymium magnets are licensed and include a triple
layer of coating for added protection. All magnet wire is top quality
Essex/REAand made in the USA.
www.homepower.corn
109
SOUR HOr HATER SVSTEJHS (3^
Self-PrzssuriHf}, Antsfrseie Closed
CLEAN: Ro^ucoCQj 6 y 2.500 lb*
P«r Year {"Driving • SrnaH Car)
AFFORDABLE 1 * Sl.OOmwrm or
SO.Q^fcWh
CHJtt
Year Wjrrjcity. FttJEx Ground . D-l-Y Mj i"uj-I
ww w. h utfe rs u n so I uti ons .co rn
(856)259*6895
Mu*!
SOLAR WAND SYSTEMS ARE:
Electricity From the Sun
Solar Electric Utility Tie
- ..
Remote Homes, Water Pumping, RVs
and Telecommunication Systems.
Call one of our
Solar Design. Technicians to
help design the right system for you.
m-m
Come in and visit us
at our NEW
AOm E
> 7 .
The BEST Tool for Solar Site Analysis
JUST SOT SETTER!
Solar
ASSISTANT
RAJSING THE STANDARD IN SOLAR SITE ANALYSIS
3953 Marsh Creek Road, Linden, TN 37096 • 317-501-2529 • Fax 931-589-5400
info@solarpathfinder.com • www.solarpathfinder.com
Now, the NEW Solar Pathfinder
Assistant software, and
your digital camera, carry
that shading information
into a concise, thorough,
professional-looking solar site
analysis report in just seconds.
Solar Pathfinder Assistant:
automatically adjusts for magnetic
declination, latitude, azimuth, tilt angle, &
tracking mode (fixed, 1-axis, 2 axis);
automatically does yearly energy computations using included NREL data
(no internet connection necessary); displays “before /after” results of
removing obstructions; and creates professional-looking reports!
The original Solar Pathfinder
with its reflective properties
gives an excellent “instant solar
blueprint” of the prospective site.
AUTOMAGIC BATTERY WATERING
WE MAKE WATER PROM YOUR GAS
HvdTOtn tKHSu r y causally nKombr-fld mIg-p.'g
w 3rd srtw rod to c^ch z^Hory tel . Hoops Brti-zrv tapped rtf tor
PdOcoded periods rt ton* and- r-educw rrw fiiorvnce certs Esftesrve
M : W" jas STOluaHy elunraflffi] \\m the kaJlery mm Gwrraw
way ard fumes Me remained rd washed bac k i n : «:■ each briery oei
Ekctrrt^e ^ tw*go r . raClendlng fr* usrtu! pewe# ar»d Ha of Iho
ballery. HYDBOCAP leptac-fl bLaJierye Baflnry
msinlen-r-ze ri isdu-ied Wme & cal bf rmne rformaHon-
305^696-2504
975 MW 95 Si
Miami FL 33150
IIO
home power 125 /june & july 2008
NEW BOOKS TO
OURC1
DO-IT-YOURSELF
£ if i
BOOKS TO WALK THE TALK
New Society Publishers
WWW.NEWSOCIETY.COM 1 800 567 6772
/soli
solarHOt
MAKING SOLAR MAKE SENSE
Manufacturing efficient, innovative
and easy to install solar heating
solutions for residential, commercial
and pool applications.
SOLVE LOl
EFF«m
urv'iw f U nH ■ top ibIkI
5 IMX iw Iwnul fc-fiam
wwv*,«4a rNrtvs?i .cwn
Ecopreneuring
Putting Purpose and the
Planet Before Profits
John Ivanko and Lisa Kivirist
How to grow your own green
business from the ground up!
$17.95
HOW TO BUILD
WITH GRID BEAM
A Fast , Easy and Affordable
System for Constructing
Almost Anything
Phil Jergenson,
Richard Jergenson,
Wilma Keppel
Build almost anything!
$29.95
c L . L^innpi
SOLAtf
Living
svo
Powering Your Vehicle
with Straight Vegetable Oil
Forest Gregg
Real Goods
Solar living
Sourcebook
Special 30th
ANNIVERSARY EDITION
The Complete Guide to
Renewable Energy
Technologies and
Sustainable Living
John Schaeffer
Fuel your diesel engine
with vegetable oil!
The essential renewable
energy resource, completely
revised and updated for 2008
$35.00
User Friendly Hydro Power
Repair Service
Parts
Upgraded Parts
for many Homescale Hydros including
Harris, ES&D, Windstream, Little Spokane,
and others.
Alternative Power & Machine
4040 Highland Ave. Unit #H • Grants Pass, OR 97526
541 - 476-8916
altpower@grantspass.com
www.apmhydro.com
www.homepower.corn
111
independent power providers
Protecting the
Interests of PV Pros
by Don Loweburg
The vast majority of PV pros — both the newcomers and
the tried-and-true pioneers who have helped shape the
industry — recognize the need for a trade organization to
protect and support their interests. These men and women
have helped the business grow into the mainstream industry
that it is becoming today, and their position in the industry's
continued evolution should be maintained. The question is:
What trade group can step up to meet this need? Maybe it is
time to reinvigorate this column's namesake organization, the
Independent Power Providers.
In 1993, the Renewable Energy Development Institute
(REDI) held a conference in Willi ts, California. The purpose of
the conference was to explore various approaches and plans
for commercializing PV. Attending the conference were utility
personnel, state regulators, PV industry representatives. Home
Power magazine staff, and solar installers. One intent of the
conference was to discuss PV commercialization proposals
funded by the U.S. Department of Energy (DOE) and the
Utility Photovoltaic Group (UPVG), a consortium of utilities
interested in pursuing PV as a utility-service option.
The basic premise held by UPVG and some within the PV
industry was that utilities would be the natural market for
the commercialization of PV. To this end, the utilities — with
the assistance of UPVG and financial assistance from the
DOE — would aggregate projects and execute bulk buys from
PV manufacturers. It was assumed that the utilities would
be a volume market and, over time, drive down the price of
PV for all customers. Using this model of "sustained orderly
development," PV manufacturers would be able to expand
production to meet the needs of all players in a predictable,
growing utility market.
UPVG's commercialization plan was to first focus on
off-grid applications as a means of familiarizing utilities
with PV. It was understood that this market itself would be
insufficient to bring PV to economic parity with grid power,
but would be a first step — to be followed later with the
commercialization of grid-connected PV systems. UPVG's
plan was that regulated utilities would offer PV systems or
services for sale to off-gridders as a means to bring them into
the utilities' rate base.
This proposal did not sit well with two groups attending the
REDI conference. First, California state regulators pointed out
a possible conflict with California Public Utility Code 2775.5,
which would "deny the authorization sought (by an electric
corporation) if it finds that the proposed program will restrict
competition or restrict growth in the solar energy industry."
Further, the statute stipulated that proposed authorization
would only be granted for a program that "would accelerate
the development and use of solar energy systems."
The second group opposed to the UPVG proposal was
existing PV installers. Fifteen years ago, the market for PV was
primarily off grid and installers saw no benefit to themselves
if utilities were to enter the PV installation business — in
fact, many of them viewed it as giving the utilities an unfair
advantage within their own industry.
Preserving the Pros’ Perspective
A majority of installers at the conference were adamant
in their opposition and decided to form a formal group to
represent their interests. Independent Power Providers (IPP)
was incorporated as a nonprofit public benefit corporation in
California on September 30, 1994, to "promote and encourage
the use of renewable energy by developing opportunities for
end-user ownership of renewable energy generation sources
and encouraging a professional installation infrastructure..."
That same year. Southern California Edison (SCE), one of
the three major California-regulated electric utilities, proposed
to market PV systems to off-grid customers in keeping with
UPVG's strategy to commercialize high-value applications
first. To do so, SCE sought permission from the California
Public Utilities Commission (CPUC) via an "advice letter"
(AL), which is intended to be used only for minor changes
in already-in-place policy. SCE framed their plan as an
experimental, three-year pilot program.
IPP responded to the AL, protesting the plan. Specifically,
IPP asserted that SCE's sale of off-grid systems would not
only restrict competition but also restrict the development
and use of PV systems in the state. The response also pointed
out that about 20 existing PV companies in California already
specialized in the installation of off-grid systems. IPP also
questioned the need and legality of a regulated utility entering
an already-competitive market for PV installation.
IPP's protest resulted in limited success. The CPUC
issued a stipulated decision, allowing SCE to market off-
grid systems but requiring them to bid the jobs out to PV
contractors. Additionally, the regulators required SCE to
hold semiannual public meetings at which the progress of the
program would be evaluated. Within these meetings, it was
understood that SCE needed to show two things: that their
program was not restricting competition or restricting growth
in the solar industry, and that their program was accelerating
the development and use of solar energy systems.
home power 125 /June & july 2008
independent power providers
IPP’s Solar
Scorecard
IPP's action over the past 15 years has strongly
influenced many aspects of the PV industry and market.
Here's a sampling of the stances that IPP has taken:
• Opposed utility ownership of PV resources on
customer sites.
• Supported net metering in California and
nationally.
• Supported rebates and incentives going directly to
the customer.
• Supported simplified interconnection to the utility.
• Opposed unnecessary extra disconnects. (California's
PG&E finally dropped that requirement in 2007.)
• Opposed the levy of "standby" and "demand"
charges by California utilities on net-metered
systems.
• Supported customer ownership of renewable energy
credits (RECs).
At the second REDI conference in 1995, as a rebuttal to
the UPVG plan, IPP presented its own commercialization
plan. The IPP plan included net metering, simplified utility
interconnection rules, rebates delivered to the customer,
UL standards and ratings for equipment, and standards for
installers. IPP and other organizations continued to promote
the ideas central to its plan, eventually resulting in some of
the earliest commercialization regulations and incentives in
the nation (see "IPP's Solar Scorecard" sidebar).
The second phase of the UPVG commercialization plan
was the development of home-scale, grid-connected projects.
Once again, IPP led the opposition when SCE stated its desire
to pursue grid-tied systems as a customer sales option. The
result was that IPP and SCE negotiated an agreement that IPP
would not protest if SCE pursued an experimental grid-tied
PV program structured like the off-grid program.
Overall, only a few off-grid and grid-connected systems
were sold by SCE, and both programs were discontinued
mainly because they were not economical for the company.
As IPP installers had long asserted, the utility's involvement
resulted in higher-cost PV systems — which few customers
could afford.
During the late 1990s, California utilities underwent
restructuring. Given the minimal success of SCE's PV
programs and the overwhelming organizational demands
of restructuring, utility PV commercialization efforts faded.
In 1996, the California legislature created a net metering
law; in 1998, it established a customer rebate program.
The new consensus held in the industry was that on-site,
customer-owned (or third-party-owned) PV would be the
commercialization pathway — the model that remains today.
What’s Next?
Veteran Virginia PV-pioneer Jeffrey Yago said in a recent
forum message, "We are dealing with many common issues,
like the lack of response from manufacturers when they
discontinue products we really need, or code groups that
listen and then go on and do what they want, and states
that make rules right out of never-never land. However, a
single voice is just not being heard, and it is getting worse
as everything gets passed down to us in a take-it-or-leave-it
dictate."
Central to the creation of IPP was the need to give voice
and status to PV pioneers whose interests — and livelihoods —
were being threatened as regulated utilities attempted to take
over the market. While IPP has served its original mission,
many valuable projects, purposes, and installer issues still
remain. Professional installers frequently cite the need for
a trade association to tackle such issues, but none have
been able to step forward to organize it. Can IPP be that
organization? The answer really depends on whether there is
sufficient interest and energy to make it so. The current IPP
board is eager to facilitate any such transition.
Access
Don Loweburg (don.loweburg@homepower.com) is a solar pioneer
in central California. He owns and operates Offline Independent
Energy Systems, and sits on the boards of the California Solar Energy
Industries Association and the North American Board of Certified
Energy Practitioners (NABCEP).
Break Free From the Pump
Enjoy the freedom of driving electric.
Join the EAA today and declare your
independence from
high gas prices
and imported oil.
ELECTRIC AUTO ASSOCIATION
For more information
visit us at eaaev.org
Finding a Green Energy Job
Just Got Easier
"This book is a gem. I highly
recommend it!" - Susan Schleith,
Florida Solar Energy Center
NEW! Careers in Renewable Energy
by Gregory McNamee $ 20.00
www.PixyJackPress.com
call 303.810.2850
PixyJack Press • PO Box 149
Masonville, CO 80541
www.homepower.corn
113
INTER NATIONAL
XC3 Solar Modules
High Quality Modules and Controllers
“This is quite a well built 85 watt panel, I am impressed. Quality
angle Aluminum; very rigid construction. ”
Orval Snyder Northwest Power CO, LLC
Distributed by:
Affordable Solar www.affordable-solar.com
Telephone: 1-800 810 9939
Please quote the special offer code "XC3" for preferential pricing.
www.xc3solar.com
Oziiiiorti®
Our 21st Year Offgrid!
We provide excellent service & technical support.
Residential Power • Water Systems • Communications
Wind • PV • Hydro • Custom Design • Installation
All Major Brands
OFF LINE
Located in the central Sierra, near Yosemite
e-mail: ofln@aol.com
www.psnw.com/~ofln
P.O. Box 231, North Fork, CA 93643
m (559) 877-7080
CA Lie. #661052
IE BE
s. 1 ' »:
MEMBER
et more energy from your system
Rated. for use with PV input up to 96
Vocjn 12/24V
Stand-Alone
Systems
20A Charge
O
ohccos
Efficient MPPT
Ready for use in
Stand-Alone Systems
Phocos USA 742 E. 46th Street Tucson, AZ 85713 USA
Phone :+1 (520) 777-7906 Fax:+1 (520) 844-6316 info-usa@phocos.com
Germany China ■ India Bolivia Bangladesh Australia Brazil
Kenya Mongolia Romania Singapore South Africa Tunisia USA
www.phocos.com
Quality Solar Energy Products
THINK THERMAL-
THINK SUNEARTH
The Empire Series Liquid Flat Plate Collector
www.sunearthinc.com
SunEarfh, Inc.
8425 Almeria Avenue, Fontana, CA 92335
(909) 434-3100, FAX (909) 434-3101
Distributor inquiries welcome.
114
home power 125 /june & july 2008
"NATURE'S HEAD"
COMPOSTING TOILET
* Na Odor
* Compact
■ Exceptional
holding capacity.
■ Urine Diverting
- An ^tjInlesA -SleeJ
Hardware
Great Far;
*Wo itkt *CaMns
*Raali
-inrr ‘Jte_
www.sustainablechoice.net
248.844.7148
Western North Carolina
Renewable Energy Initiative
2008 Workshop Schedule
4/5-6 Solar Water & Space Heating:
with Chuck Marken of Home Power & AAA Solar
4/19-20 Small Scale Wind Energy:
with Southwest Windpower
5/22-23 Photovoltaics:
with Sharp Solar
7/11-12 Domestic Solar Water Heating:
with AET & Brandon Leavitt
8/27 PV & The National Electrical Code:
with John Wiles of the Southwest Technology Development Institute
10/4-5 Micro Hydro:
with Don Harris
10/18-19 Small Scale Wind Energy:
with Southwest Windpower
Other North Carolina Events:
March 8: Organic Growers School, Flat Rock, NC
August 12-13: Western NC Green Building Council workshops, Asheville, NC
August 22-24: Southern Energy & Environment Expo, Fletcher, NC
November: NC Energy Star Conference, Raleigh, NC
www.wind.appstate.edu
828-262-7333 • email: wind@appstate.edu
Bachelors and Masters degree programs available
K Appalachian
■V 1 1 STAl]-: rMVERSJTV
State Energy Office
7) PQpm" gk&B&uajg/p
Four SunPipe-13's in 25 x 35 living room.
The Best Daylight Pipe
The Brightest Daylight Pipe
No Heat Gain, Roof Leaks or Electricity
WWW.SUNPIPE.COM - 800-844-4786
WAirSUN
YYatKiin S-olar Tfjcfcen
Residential
S-ng'c n DiMhAill Aivmuth
f-rHiaa TlMEkif * rmKinl Mrf
— - —
J i- lip WjiTi cf p^iatovciNalc
m ad ill#*
Tt, jT
1
jC / /
ggriinnwcMl
1
- ■ J
Fixs-tfr-T-TI Aiimwih Stiiw
■ |
Tiacluri Uaunf i 1 tu A Liki ft jics
HZ-Lnt*r AkIs Utaher*
f j I
lOlfriO fcliM Jrnj
J
he Lht biK iMJllEflng blocki
UA PtfFWii Pljnln
"mm *
■AHRA.Y TFCHP-^QL QCIFS IRC
F ! B 1 FTni B HI "I - ■ 1 T Iff S T ^BTH! ^ ^ 1 l 1 T B W i
phene WS-8B1-T567
i«: ■g7e ^M-57M
WWW WATTSUH.COM
Anl n.n Tl. Jin m il» 1. ml m ?>■ rU
www.homepower.corn
power politics
Getting FIT
by Michael Welch
The recent changeover to a "greener"
Congress is showing some benefits to
the renewable energy world.
Congress is now drafting bills to form federal policies
supporting household and small-scale commercial RE that
go way beyond net metering. Feed-in tariffs (FITs) may be
the next promising step for RE development in the United
States.
Whereas net metering is designed to offset household or
business usage, renewable energy FITs typically provide a
premium price per KWH (as in production-based incentives,
or PBIs) when a system produces more electrical energy
than the building consumes. Some programs also pay
that premium for offsetting usage even before the using/
producing breakeven.
Incentives for both of these government-mandated
programs — net metering and FITs — are funded through
surcharges that all utility customers pay. The amounts used
to fund these programs are charged on a per-KWH basis
and lumped in with the utility's "public purpose programs."
These have also been established to help cover the costs of
providing assistance to low-income utility customers and
financing energy-efficiency programs.
Growing the RE Garden
State-by-state net billing laws have served the renewable
energy industry quite effectively so far, as indicated by the
increasing number of home-scale PV and wind installations —
and professional installers — in the states with effective rules,
compared to those states without net billing. From an industry
perspective, the point of those laws was to give a budding
industry a little "fertilizer" to help it grow and gain solid
roots to become self-sustaining.
Now that the RE industry has established itself in the
United States, it is time to propagate it by including those
states that have not had the political will to establish their own
effective programs. More nurturing incentives could shift the
industry from its current status of "present and ready" to the
next stage: rapid growth of manufacturing facilities, dealers,
and installers and, with that, price decreases.
The timeliness of this next step will be important to
uprooting the weed of climate change. We must speed up
necessary greenhouse gas reductions, or else risk reaching a
tipping point beyond which global warming does not have
a reasonable recovery scenario. Accelerating the growth of
RE by taking incentives to the next phase can help achieve
this goal.
Feed-in tariffs are nothing new — Europe's successful
systems of "rate-based incentives" have long been the envy
of RE advocates in the United States — so understanding how
they accomplish industry growth here should be predictable.
The German model, perhaps most often heard of, has been
triumphant at increasing the installation of RE in that country.
Only one European country has more installed PV per capita
than Germany's approximately 30 watts peak, and that is
Luxembourg, with more than 50 Wp per capita from its wildly
successful, but temporary, rate-based incentives program.
The German model was so successful that its programs
(along with a couple in other countries) temporarily created a
worldwide shortage of PV modules. German installers were
willing to pay higher-than-normal retail prices for modules —
even within the wholesale market. Shipping containers
full of modules were being resold into Europe from other
countries — even coming directly from U.S. retailers and
distributors — because the price was right.
The key to the success of these programs was in making
the tariffs as attractive as possible. The higher the profit
potential for would-be system owners, the more likely they
are to invest in systems. Considering the immediacy and
risks of continued climate change, the price of PV energy
generated on site could easily be valued at 50 cents per KWH
or more — admittedly a seat-of-pants estimate, but in line with
the German model and enough to make even the most thrifty
of utility customers sit up and take notice.
United States FITs Next?
Leaders of both houses of Congress have drafted FIT bills.
As of this writing, no bills have been introduced, but citizen
input is being sought. In the House, Representative Jay Inslee
is drafting The Clean Energy Buy-Back Act, which would
amend the Public Utility Regulatory Policies Act (PURPA)
116
home power 125 /June & july 2008
Presidential Promise
While the threat of vetoing legislation not supported by
the current administration still exists, bills introduced
now may not even make it all the way through the
current legislative session, which ends in the fall for
both houses. This is good news, since this could
delay the bills until after a new president is sworn in.
The three viable presidential candidates are all more
likely to support RE and climate-change legislation
compared to the current administration. It is time
to raise our hopes for a renewable energy, climate-
neutral future, and to back them up by encouraging
our Congressional representatives to work harder than
ever to make it happen.
to require utilities to enter into 20-year fixed-rate power
purchase agreements and to set those rates to provide system
owners with a reasonable rate of return on investment.
Though the PBI amounts that have been so effective in Europe
have not been specified in these bills, it would be a huge step
forward as envisioned.
Senator Bernard Sanders of Vermont is working on a bill
that's similar to the Inslee draft in intent and content. His
National Renewable Energy Sources Act would make PBIs
power politics
the law in all states. Both bills would amend PURPA, set rates,
and spread out the costs among ratepayers, though no details
exist yet. Neither draft precludes other state, federal, or local
incentive programs, such as rebates and tax credits.
Right now we have a unique opportunity to chime in
before these drafts are finalized. Make sure that the legislators'
staff understands the need for high PBIs if they truly want to
see results as effective as the European programs. See Access
for the contact information for Congressional staffers who
are working on these bills. Then take the time to call your
own representatives in Congress and ask them to sponsor
the bills when the time comes. While you're at it, be sure to
put in a plug for renewing the federal tax credits, which will
otherwise expire on December 31, 2008.
Access
Michael Welch (michael.welch@homepower.com) has been working
for a clean, safe, and just energy future since 1978 as a volunteer for
Redwood Alliance and with Home Power magazine since 1990. He
will be spending the next year in Sacramento, California, where he
hopes to help hold the Governator to his RE promises.
Representative Jay Inslee's Staff Contact:
James Bradbury • 202-226-7449 • james.bradbury@mail.house.gov
Senator Bernard Sanders's Staff Contacts:
Jessica Maher • 202-228-6356 or Bill Hutzel • 202-228-6493
$ 85.00
KALER3
WELCOME
solar powered
DIFFERENTIAL TEMPERATURE
CONTROLLER
Improves the performance
of solar heating systems
For 12 or 24 Volt DC pumps
www.Art.TEcSolar.com
DESIGN & INSTALLATION
Red Lodge, MT • 406-855-8824
www.effidentradiant.com • efficientrad iant@yahoo.com
BZ Products Model MPPT250
250 watt 25 amp Maximum Power Point Solar Control
• Boost charge current up to 30%
• Up to 25 amp output current
• Microprocessor control
• 95 % efficacy
• 250 watt PV input
• 12 to 24 volt input
• Digital metering
• PWM float control
• Battery temperature sensor
standard
• 15 amp low voltage
disconnect standard
• Aux battery trickle charger standard
• Five year warranty
• Made in U.S.A.
BZ Products, Inc.
644-2490 • www.bzproducts.net • bzp@bzproducts.net
7914 Gravois, St. Louis, MO 63123, USA
Artha
— #■ * ■* —
[ iviiift ( / rtlc-r
Solar Thermal Services
professional site assessments
system design and consulting:
1 i commercial & residential, domestic & space heating
^ hands-on installation training workshops:
_® on or off site, NABCEP continuing education
CD
| www.arthaonline.com
www.homepower.corn
117
PV PE
IALS
Simple.
acme conduit entry (ACE)
hassle free wire transition,
any conduit type
Safe.
washer, electrical equipment bond (WEEB)
bonds modules to racking for safer grounding, listed to UL 467
Available for: Professional Solar, UniRac, DP&W Power Rail, Two Seas, Schuco, Conergy
Secure
acme cable clip (ACC)
easy installation, non corrosive stainless steel
Available for USE-2 and PV Wire
Accurate
acme solar site evaluation tool (ASSET)
digital solar site evaluation with user friendly software
/WILEY
r j ELICTMHtCL LLL
Tel: (845) 247-2875
(845) 633-2065
www.we-llc.com
SliNDA Evacuated Tubes
Aerpspaca TBchnpIpgv for
Sular W ater Heating
Alfonfable vacuum lube coHetl&O
lor supertoi partarmanBe in fri
E-taions a^vJ rirrMSSs
frmntG lid Wate* 5 Home n w ng
Cuyn-n-ii^i f hn imuKrt^l
AfrtOiRuf Jj i" KhZullfb*
u.u
Ari Jilatil#- rjh-;LH#C |i IPuni^h jn
axpasiiliiiy iIitbIm nnlw:iifei
JO ' 1 1 uu r UM I
T<ikilnn And LtchnJcfeliujppMi
SjIi SfKA SlMjt
PD Bs>x E-5-
M WdlwC*p. PA f BUT
Inl^mL-icUrd^nt I Iijfi*iYi
Want to Save More Energy & Water?
.Vim? (iM//r»i.v fwi/i /.avh/ H jJ/j .Vfflfter/
5TABER
Only Top Horisonta}- AsH Wi^lior
Miidf In Ihe USA-Great forOIT-Griil System i!
-Av*g. irf I * gillcn (if tvOIct A. I
i.i i iQrif pvi 3 iki( 1
'AW ill jLnl .15 LA\1| fliM Ii jJ
rilJiifclL-- > -Lied mriLi if guIlt IlMil
-Dim] Kviuiui '.n liunl <£ real cVi
Jlurdb-ilin
OCp li .in: rubber vJ--LlI Id yl-ihti
jhiul k.ikj iHf ur n iI-.Il'.i
- lulal friTTil iu- part*— htvtJ
r mipk J^Titqn oq ski* m irttf
-Sills : 1 1 -J-L Kill i _ . L I rwrtLhCt—fh>
L\p-wEHfc'ii_ lIlJIi-N-l h|;-|,-.n^!
■|[t^li c\li j.n.1i-;ui *pm ■■I'-ciJ
-MADE i>:tiie usai
| C hIT I -86 0-848-6200 to Iffini more! [
sm^tibcrnni
Sbln liiJiiHim. In: «» Him Ofa. tdi OH 411V H|
Energy Efficient
Refrigerators & Freezers
Customized To Fit Your Needs
► Available in DC
or AC
► Select From Over 10
Models
► Choose from 1000's
of Colors, Finishes fit
Woods
We also Manufacture
Composting Toilets!
Please Contact (Is For More Info
P.O. Box 1101. Areata. Cfi 95518
tel: (707)822-9095 - fax: (707)822-6213 info@
sunfrost.com ■ www.sunfrost.com
118
home power 125 /june & july 2008
3622 South Morgan Street
Chicago, Illinois 60608
T 773.847.8333 F 773.847.8555
www.solargenixchicago.com
info@solargenixchicago.com
The Winston Series
Parabolic Concentrating Collector
Designed at the University of Chicago;
Manufactured in the USA
Solargenix - An Enlightened Approach
to Solar Thermal Energy
Introducing the S-5-PV Kit, a
revolutionary new solution to attach solar PV
panels to standing seam metal roofs!
Crystalline PV modules mounted
with the S-5-PV Kit to a standing
seam metal roof produces a
reliable 30-year alternative power
source. The patented design of the
attachment clamp and attendant
round-point setscrews enables an
entire installation without a single
penetration of the roofs surface!
Installation is quick and easy.
888-825-3432 www.S-5.com
Low head turbine:
• Works with heads
of 2 to 10 feet
and large flows
• Low flow
runner option
Higher head turbine:
• Operates at heads
of 10 feet and up
• High output wheel
option for heads
over 50 feet
Both turbines:
• Use permanent
magnet brushless
alernators
• Charge 12, 24, 48
Volt batteries or
higher voltage for
long distance
• Have cast
bronze runners
• Generate up to 1 KW
or more at best sites
Energy Systems & Design
“ Innovative turbines since 1980”
Manufacturing cost-effective
water powered generators
For more information:
www.microhydropower.com
506-433-3151
NABCEP
CERTIFICATION
Get THE Distinquished Mark
for Renewable Energy Professionals
Since 2003, the North American Board of Certified Energy
Practitioners (NABCEP) has been awarding professional credentials
to renewable energy installers. NABCEP’s rigorous competency
standards for certification sends a clear message to consumers,
financers, and public officials that the Industry stresses high quality,
safe and ethical business practice and workmanship standards.
NABCEP PV or Solar Thermal Certification...
THE One That's Hard to Get
To find out how to become a Certified Installer please visit:
www.nabcep.org
Next NABCEP Exam September 13th
www.homepower.corn
119
\m®
Pod
Home Field
by Kathleen Jarschke-Schultze
Fve often been amused by the " green speak" that's grown
up around diet choices. There are the vegans (no animal or
animal by-products of any sort are consumed), the vegetarians
(no food from flesh), the aquarians (eat seafood), pesco-pollo
folks (eat fish and poultry), the beady-eyed vegetarians (if it
has beady eyes, they'll eat it), the omnivores (eat anything
and everything), and the opportunavores (eat what's placed
in front of them). Now there are some new words in the
lexicon of diet choices.
Living la Vida Locavore
I've just finished listening to the audio book of Barbara
Kingsolver's Animal, Vegetable, Miracle: A Year of Food Life
(www.animalvegetablemiracle.com) for the second time. It is
so inspiring and informative on many levels. Barbara's family
of four chronicles a year living as locavores.
A locavore (sometimes called localvore) is someone who
gets their food — animal or vegetable — from within 50, 100, or
150 miles of their home, depending on their region. Their larder
comes generally from their own gardens, a CSA (community-
supported agriculture) farm, and local farmers markets.
Locavores support their local economy by local purchasing.
This is also called "food patriotism."
Groovin’ on Sole Food
An ethicurian is someone who seeks out tasty things that are
also sustainable, organic, local, and ethical — SOLE food, for
short. This is the definition at www.ethicurian.com, whose
motto is, "Chew the right thing."
After seeing the video clips of the cruelty to cows at a Chino,
California, beef-processing plant, which resulted in the recall of
143 million pounds of frozen beef. I'm a converted ethicurian.
The undercover video, shot by the Humane Society of the
United States, showed workers abusing "downer" animals that
were apparently too sick or injured to walk into the killing box.
Federal regulations call for keeping downed cattle out
of the food supply because they may pose a higher risk of
contamination from E. coli, salmonella, or mad cow disease, as
a result of their weakened immune systems and being forced
to wallow in their own feces. Of course, after the fact, we found
out that a lot of the meat from this plant was sold to school
lunch programs and had been eaten by children already.
home power 125 /june & july 2008
home & heart
In the United States, about one-tenth of 1% of beef cattle
are tested for mad cow disease. In Europe and Japan, 100%
are tested. The human form of mad cow disease happens
when infected cows are eaten by people. The cows get it from
eating ground-up cow waste. After the mad cow scare, the
United States banned feeding cow waste to cows. Now they
feed it to chickens and pigs. And then they feed chicken waste
to cows. This process does not eliminate mad cow disease. It
simply travels through the literal loops — as viable as ever.
Shop, Shop Around
Growing your own meat is a big undertaking. If you can do
it, great. If you can't, the next best thing is to know the person
who raised it. Right now my Sun Frost freezer is holding half
of a hog my husband Bob-O and I bought from people we
know. Many local markets now offer a number of "ethical"
choices for meat and fish. Farm-raised, grass-fed, pasture-
finished, free-range — we all should become familiar with
these terms if we're into SOFE food.
Of course, few of us can grow all our own food — even
those of us with big gardens can't grow every single thing we
want. Weather and geography intervene. To eat seasonally
where I live would take a lot of canning, freezing, and drying.
I am lucky that there is a wealth of farmer's markets, local
vegetable stands, and natural food stores around here. To find
local food supplies in your area, visit www.localharvest.org.
Sustainability Grows
Michael Pollan, author of The Omnivore's Dilemma: A Natural
History of Four Meals and In Defense of Food: An Eater's
Manifesto (www.michaelpollan.com), has a few suggestions.
He says don't eat anything your great-grandmother wouldn't
recognize as food. Similarly, he advises, if a packaged product
contains more than five ingredients, it's probably not food. He
removed the lawn at his home in the Bay Area and put in a
vegetable garden.
I know people who are and have been ethicurians before
there was a word for it. Vegetarians Sue Robishaw and
Steve Schmeck (www.manytracks.com) experimented with
really local food, living for a year on what they could raise
themselves. This was years ago, and I remember Sue saying
vegetable oils were a stumbling block for them.
A couple of years ago, I took Earisa Walk's workshop,
"Eating From Your Garden Year-Round," at the Midwest
Renewable Energy Fair. She and her partner Bob Dahse have
the most wonderful Web site (www.geopathfinder.com). For
their tips on growing local, click on "Veggie Homesteading"
and "Food Preservation."
Keeping It Real
This cascading revelation about locavorism has impressed me.
I've been growing only open-pollinated seeds for years (www.
bountifulgardens.org). These are seeds that can be saved from
the mother plant and will grow true when planted. Heirloom
varieties, as they are often called, are enjoying increasing
popularity. I try my hand at saving some seeds, the easy ones.
I had a friend who told me once to let one of everything go to
seed in my garden. I always have a lot of volunteers — plants.
Regional Eating
In winter, when you shell out a few bucks to buy a
tomato, cantaloupe, or grapes at your supermarket, the
real costs of growing and shipping are not revealed.
How much did it cost to get them there? The importer
doesn't care. They get to deduct the cost of transport.
But resources are being used. Oil is being used up.
Even within the United States, enormous amounts of
fuel are used to transport factory farm produce across
our country. CUESA (Center for Urban Education about
Sustainable Agriculture; www.cuesa.org) estimates that
the average American meal travels 1,500 miles from field
to fork. It is estimated that if every family in the country
ate just one meal per week from locally procured food,
we could save 1.1 million barrels of oil per week.
Eating regionally and getting your food locally not only
reduces reliance on fossil fuel, but it helps keep dollars
local, stabilizing regional economies. An additional
benefit is that it helps keep our communities healthier —
fresh, organic, whole, locally harvested foods have more
vitamins and minerals than their packaged counterparts
and none of the pesticide residue possible in factory-
farmed or imported foods.
Choosing local rather than processed foods also keeps
trans fats and high-fructose corn syrup, which have been
linked to heart disease and diabetes, off our shelves and
out of our diets. Adult-onset diabetes has been renamed
Type II diabetes because so many children have become
victims. Sadly, for the first time in history, the current
generation of children is not expected to have a longer
life span than their parents.
that is. I've also learned that when the lettuce volunteers come
up, it is time to plant lettuce. When the potato volunteers
break ground, it is time to plant potatoes.
My locavore challenge is to figure out what produce I
end up buying at the grocery store and to see if I can grow
that particular variety at my house. For my kimchee recipe, I
can make or grow every ingredient except napa cabbage. But
this year I bought a slow-bolting, open-pollinated variety. If
I can get it to head up in the dry heat. I'll not only have my
kimchee cabbage, but also will be able to save seeds and add
them to my seed bank for next year. Of course, that means I
need to organize my collecting better. While cleaning off my
desk recently, I came across a taped-shut, half-used envelope
of "Cabernet Fettuce '07."
Green Food Housing
I have been using a small lean-to greenhouse for starting
seeds. I framed in the area beneath the 3-foot overhang on the
southeast side of our house, and put up fiberglass greenhouse
panels and a door at both ends. When we replaced our
windows in the house with double-paned units, I mounted one
of the old windows above one of the doors for ventilation.
For a planting table, I built a long, two-shelved bench
and covered it in hardware cloth. For years, this is where I
www.homepower.corn
home & heart
have started my seedlings. My problem has been the mice
that come and eat my seedlings or dig up the seed before
it has even sprouted through the dirt. The greenhouse is
so ramshackle that I could never completely seal it against
rodents, and the whiskered critter invasion has been so
discouraging that I had taken to buying organic starts
rather than starting my own.
So this year I bought an 8- by 7.5-foot greenhouse. Since it
is constructed as one piece. I'm hoping it will end my mouse
problems and enable me to enlarge my gardening repertoire.
I'm trying several new varieties this year, thinking ahead to
saving seed and preserving the crop. I've taken to buying
a vegetable variety to see if we like it, and then see if I can
grow it.
ELECTRIC BIKES
“No better quality at no better price”
800 - 806-7109
Complete BIODIESEL Production System
Lower Your Fuel & Energy Cost TODAY!
Dealer Opportunities Available!
- Make Fuel the Day It Arrives
- Safe, Durable, & Effective
- Completely Assembled and Tested
- Handles New or Used Vegetable Oil
- Consultation Services Available
- Monthly Biodiesel Seminars!
The Ester Machine™
We Have theAnswers to Your Biodiesel Questions!
Green World Biofuels www.greenworldbiofuels.com 319-545-7022
Chock o’ Choices
There are a lot of factors involved in being a locavore or
becoming an ethicurian. It doesn't have to be done all at once.
Awareness is the first step. It's a lot of commitment, effort,
and self-education to make choices that support the ideals you
believe in. I have to admit that it's going to be hard giving up
bananas. Maybe I can relieve my conscience by just buying
the aged ones that are already wearing red discount ribbons.
And thank goodness for fair-trade goods, 'cause we're not
ready to give up coffee — or chocolate, for that matter.
Access
Kathleen Jarschke-Schultze (kathleen.jarschke-schultze@homepower.
com) is enjoying her new greenhouse at her off-grid home.
LIVING WITH NATURE
IV
“ Sustainable Living & Green
Building Festival ”
Marathon, Texas
August 1-3, 2008
www. livingwi thnatur e . net
i
If
Things that Work!
Model 4-1850
Honi.e Power -#6 ~
Digital Power Meters
20-CTR: Measures AC Power up to 10
kW, 100-250 vac single or two phase.
New USB plug in meter, up to 1 gig of flash memory!
ONEMeter: Standard Features include Multiple AC or DC power
channels, PC interface, internal logging. Options include Web
Interface, Weather Monitoring, and lots more.
4-1850WX: Special meter for Refrigerator Replacement
Programs. Detects Defrost Cycle, displays cost/kWh-hrs/yr.
Other Models available. Check our website or call for details.
All products are California
CEC eligible meters
Brand Electronics
info@brandelectronics.com
Ordering or Information call
12891 - 315-7744
www. brandelectronics. com
Why not use free energy?
ENERGV WISE
SOLUTIONS
ENERGV WISE
SOLUTIONS
Your one-stop
renewable energy
online store
980-621-0716
www.energywisesolutions.net
home power 125 /june & july 2008
COMBINE SCIENCE & HANDS-ON TRAINING
FOCUS ON PHOTOVOLTAIC DESIGN AND INSTALLATION
TWO YEAR A.A.S. DEGREE OR
ONE YEAR CERTIFICATE PROGRAMS
BOTH EMPHASIZE FULL N.E.C. COMPLIANCE
PLEASE VISIT US ONLINE AT WWW.SanjuailCOlle9e.edu/ren9
■V VH FOR ADDITIONAL INFORMATION ABOUT THE
RENEWABLE ENERGY PROGRAM AT
SAN JUAN COLLEGE, FARMINGTON, NM
PLEASE CONTACT: TOM MUNSON
(505) 566-3003 OR (800) 241-6327
munsont@sanjuancolle9e.edu
NABCEP
CERTIFICATION
Select a NABCEP certified PV and solar thermal
installer for the highest quality installation
“our PV system was a
big investment in the
future and I wanted it
installed by a profes-
sional with national
credentials to make
sure it was installed
properly. The NABCEP Certified installer
did just that, and the system is operat-
ing flawlessly.”
Mike Burnetter, Home Owner
and Professional Engineer
The North American Board of Certified Energy
Practitioners (NABCEP) awards professional
certification to solar electric (photovoltaics)
and solar thermal installers. NABCEP’s high
standards are designed to protect consumers
and enhance the profession.
Select an installer with the NABCEP PV or
Solar Thermal Certification. . .
THE One That's Hard to Get
To find nationally recognized Certified Solar Electric and
Solar Thermal installers in your area go to:
www.nabcep.org
SOLJPffST 2006
The New England Renewable Energy Festival
Three days of workshops, music and
performances promoting, celebrating and
enabling sustainable living
and renewable energy.
• 50 free workshops
• Over 1 00 vendors and exhibitors
Children^ activities
camping
r week long
oui
• On-site c
Sign up now for
in-depth PV101 workshop
July 11, 12 & 13
Forget-Me-Not Farm Ti
Tickets on sale
Sponsored in part by:
Forget-Me-Not Farm, Darkst
Noble Environmental
■aaEierg
1011th, VT
& Production
tBack Power Systems
>lar
Info & Tickets at www.solarfest.org
Cells* & Battery Boxes
Universal Track Racks™
& More
Ptfrtri •
Zome works Corporation
&00-279-S342 " jpmrwtirkWjrOrwcwgrisManil
Simple, Reliable Products
See Double Play Systems Performance
w ww.zo mewo rks.co m
www.homepower.corn
Do You Need Batteries?...
RAE Storage Battery Company
Since 1943... Quality & Service
Surrette Solar 1, 400 Series,
Type CH 375 - LI 6
Engineered under careful guidelines
by Dave Surrette - Family owned
business Est. 1 935
Gambissara Solar for export
212-206-6344 • 1201 Broadway,
Room 809, New York, NY 10001
Newly established factory
warehouse. U.S. Battery Co.
Corona, CA
Phone 860-828-6007
Fax 860-828-4540
51 Deming Rd., POB 8005,
Berlin, CT 06037
BZ Products Model MPPT500
500 watt 45 amp Maximum Power Point Solar Control
• Boost charge current up to 30%
• Up to 45 amp output current
• Microprocessor control
• 95 % efficacy
• 500 watt PV input
• Universal PV input 12 to 48 volts
• 12, 24 or 48 volt output
• Digital metering
• PWM float control
• Battery temperature sensor standard
• Five year warranty
• Made in U.S.A.
BZ Products, Inc.
i-2490 • www.bzproducts.net • bzp@bzproducts.net
7914 Gravois, St. Louis, MO 63123, USA
• Simmons •
Natural Bodycare
si mmonsnatu rals.com
MAKING
EVERYDAY
SPECIAL
Off the grid since 1982 .
A SUSTAINABLE FUTURE
PC Software for Sine Inverters
Wit iVerter m
rQHIl jpiliRTll
xantrex
www.RiBhTHandErq.CQm |425) 844-1291
WINDMAX
( 't ) Wind Energy Store (f?
Top quality, efficient, do-it-yourself wind turbine components
^Powerful Neo Magnets
^High Efficiency Blades
^Top Quality Magnet Wire
^Wind Generators
^Wind turbine plans
Wind Max Energy - Future of Ren
Phone: 1-877-801-9778, 972-801-9778
Web: www.magnet4less.com
Addr: 1111 Summit Ave. #8, Plano TX 75074
ewable Energy
1 *r\i
w
"Tfcv
'78
TX 7507 A
■ r ft
WITH
JT-j
WWM 6W??X
Ck - .
* ^Sr 5 * 1
ULTRA LOW ENERGY
with only 25 - 130 WATTS!
t ' • «
The most efficient coolers on the planet.
12, 24, & 48 Volt DC Evaporative Coolers.
ft ^
Also available in 120 & 240 Volt AC.
Made from Stainless Steel = Long Life!
KAR KOOL FOR YOUR VEHICLE
Call SOUTHWEST SOLAR
We Make COOLING Your Lowest Electrical Load!
(520) 885-7925 Tucson, Arizona, USA
southwest-solar, com
BATTERY BOX
VENTILATOR
& BACK DRAFT DAMPER
www.zephyrvent.com
Available from dealers and distributors
in the U.S., Canada and Australia.
ZEPHYR INDUSTRIES -POB 52. SALIDA, CO 81 201 • 719.530.0718
Harness the energy from the most powerful
muscle group in your body.
Generate efectricity with your bicycle
L and the Bike Power Generator.
%
www.windstreampower.com
sales@windstreampower.com
Phone 802-425-3435
FAX 802-425-2896
home power 125 /june & july 2008
LED LIGHT BULBS
Save Over 90% On Your Lighting Bill
60,000 Hour Bulb Life (est.) • 2-year Warranty • ©
UL Listed
CC Vivid PAR 38
LED Spotlight
• Outdoor Sensor
or Exterior Lighting
• 72 Bright White LEDs
• 8 Watts / 12 or 120 Volt
CC Vivid +
LED Light Bulb
• Porch, Reading or
Ambient Light
• 36 Bright White LEDs
• 3 Watts/ 12 or 120 Volt
CC Vivid PAR 20
LED Flood & Spot
• Ceiling or Garden
Accent Lighting
• 36 Bright White LEDs
• 3 Watts / 120 Volt
CC Vivid PAR 30
LED Floodlight
Ceiling or Garden
Accent Lighting
•60 Bright White LEDs
• 6 Watts / 120 Volt
These bulbs fit most standard fixtures.
Additional sizes and voltages available.
d.d RFINIEL
800-522-8863 • ccrane.com
w
E@
WIND DATA LOGGER
for wind site assessment,
turbine monitoring,
and weather station
applications
High performance and very low
cost. Supports multiple anemo-
meters, wind vanes, temperature,
relative humidity, light level,
voltage and current, and many
other sensors.
Logs directly to removable Secure Digital card. PC and cell phone
interfaces available to capture live data and send to the internet or
through e-mail. Ready to go packages available — just give us a
call or visit our website!
APRS World, LLC
Phone: +1 -507-454-2727 Web: www.winddatalogger.com
902 East Second Street, Suite 320, Winona, MN 55987
Off-Grid Solar Energy
Specialists
We’ll help you through the confusion
with the best design and components
for your off-grid installation.
8+ years solar installation experience
• Full support for do-it-yourselfers
► Wiring diagrams for your system
» Packaged systems available
CSffJf
off Major
Brands
We can build it -you can install it.
toll-free: 888-782-0706
7 www.apxsolar.com
HYDBDSCRtIH CD. llfi
• Self Cleaning
• Easy Installation
• High Capacity
• No moving parts
• Pipe , ramp and
box mountings
Precision Wedge Wire
Coanda Screens
for Hydro, Agricultural, and
Domestic Diversions from
10 gpm to 500 cfs
- We specialize in creatively engineering solutions
for your unique hydro diversion screening needs.
- Our solutions are cost effective with numerous
screen mounting options; we also have
durable 304 SS mounting boxes.
Visit us at www.hydroscreen.com
or call (303) 333-6071
e-mail: RKWEIR@AOL.COM
We don’t just sell screens,
we engineer solutions!
JWP-Jan Watercraft Products
Battery Watering Made Easy!
RV, Off Grid
Marine
Golf Carts
PRO-FILL is not only for your “HOME POWER”
applications. You can also use on your RV, camper, boat, golf
cart... Get the picture? Visit our web site to see ALL of these
applications. PRO-FILL, the most convenient and accurate
means of filling and maintaining battery water levels. Period!
5 year warranty, free shipping in USA.
VISA
Distributed by: JWP
E-mail: sales@janwp.com
Call Bob- 1-616 822-7587
www.janwp.com
NO Gas
NO OH
NO Carbon
NO Warming
NO Smog
NO Wars ,
info@ Gorilla Vehicles, com
PLEASE SEE OUR WEBSITE
or call for a brochure package
Gorilla Vehicles
5842 McFadden Ave, Unit R
Huntington Beach, CA 92649
(714) 377-7776
www.homepower.corn
SOLAR WATER HEATING
Commercial • Residential
Solar Radiant Floor
26 years
of industry leadership
Temperature Limited
New Mazdon HP 200 System
solarthermal.com
IT'S ALL IN THE
VACUUM
Save up to 80% on
Heating bills
All weather performance
Low Maintenance
zev@solarthermal.com
Call Toll Free
1 - 888 - 923-9443
Ask About Dealerships
RE happenings
U.S.A.
CALIFORNIA
Jun. 9-11, '08. San Francisco. PV System
Design — Producing PV design documents. For
engineers & designers. Info: 707-869-9391 •
www.sunengineer.com/workshops.htm
Jun. 18-20, '08. San Diego, CA. PV Summit
2008. Industry & market trends. Updates on
silicon supply, PV technologies, concentrated
PV, next generation thin-films, dye-sensitized
solar cells, organic PV & emerging applications.
Info: www.intertechpira.com
July 15-17, '08. San Francisco. Intersolar
North America. Exhibition focuses on
photovoltaics, solar thermal technology, and
solar architecture. Seminars & workshops on
current industry trends. Info: Solar Promotion
International GmbH • 415-248-1257 • wagner@
intersolar. us • www.intersolar.us •
Jul. 22-24, '08. San Jose, CA. Plug-In 2008 Conf.
& Expo. Latest tech advances, market research
& policy initiatives on plug-in hybrid-electric
vehicles (PHEVs). Info: www.plugin2008.com
Aug. 10-14, '08. San Diego, CA. Solar Energy
Applications, a part of SPIE Optics+Photonics
conf. Tech presentations & courses on PV; R&D
of solar concentrators & solar hydrogen. Info:
www.spie.org
Aug. 16-17, '08. Hopland, CA. SolFest. RE
booths, workshops & kids' activities. Food &
entertainment. Info: www.solfest.org
Oct. 13-16, '08. San Diego, CA. Solar Power
2008. Conference & expo. Info: SEIA •
202-296-1688 • mglunt@solarelectricpower.org •
www.solarpowerconference.com
Areata, CA. Workshops & presentations on RE
& sustainable living. Info: Campus Center for
Appropriate Technology • 707-826-3551 •
ccat@humboldt.edu • www.humboldt.edu/~ccat
Hopland, CA. Workshops on PV, wind, hydro,
alternative fuels, green building & more. Solar
Living Institute • 707-744-2017 • sli@solarliving.
org • www.solarliving.org
COLORADO
Sept. 20-21, '08. Fort Collins, CO. Rocky Mt.
Sustainable Living Fair. Exhibits, workshops,
RE, alternative vehicles & more. Info: Rocky Mt.
Sustainable Living Assoc. • 970-224-3247 •
kellie@sustainablelivingfair.org •
www.sustainablelivingfair.org
Crawford, CO. Solar Energy for Do-It-
Yourselfers '08 workshops: Jun. 6-7: Solar
Ovens, Cookers & Dryers; Jun. 14-15: Intro to
PV; Jun. 27-29: Batch Solar Water Heaters; Jul.
12-13: Solar Hot Air Collectors. Info: Our Sun
Solar - 970-921-5529 •
www.solarenergyclasses.com
Carbondale, CO. Workshops & online courses
on PV, water pumping, wind, RE businesses,
microhydro, solar hot water, space heating,
alternative fuels, straw bale building, green
building, women's PV courses & more. Info:
Solar Energy Inti. • 970-963-8855 • sei@
solarenergy.org • www.solarenergy.org
FLORIDA
Melbourne, FL. Green Campus Group meets
monthly to discuss sustainable living, recycling
& RE. Info: fleslie@fit.edu • http://my.fit.
edu/~fleslie/GreenCampus/greencampus.htm
ILLINOIS
Aug. 9-10, '08. Oregon, IL. IL RE & Sustainable
Lifestyle Fair. RE booths, workshops, tours &
kids' activities. Food & entertainment. Info:
www.illinoisrenew.org
IOWA
Sep. 13-14, '08. Cedar Falls, IA. I-Renew
Energy Expo. Workshops, exhibits, food,
entertainment. Info: See listing below.
Iowa City, IA. Iowa RE Assoc, meetings. Info:
319-341-4372 • irenew@irenew.org • www.irenew.org
MASSACHUSETTS
Sep. 15-17, '08. Boston. Alternative Energy
Sources & Technologies. Conf. & exhibition on
biomass, biofuel, geothermal, hydro, hydrogen,
solar, wind & waste-to-energy. Info:
www.cardellexpo.com
Auburn, MA. Seminars: Solar Basics, PV, Hot
Water, Wind, RE & more. Info: CNE Solar Store •
508-832-4344 • peter@cnesolarstore.com •
www.cnesolarstore.com
Hudson, MA. Workshops: Intro to PV; Advanced
PV; RE Basics; Solar Hot Water & more. Info:
The Alternative Energy Store • 877-878-4060 •
support@altenergystore.com •
http://workshops.altenergystore.com
MICHIGAN
Jun. 27-29, '08. Onekama. Ml Energy Fair.
RE, EE, green building & alternative vehicle
workshops & vendors. Food & music. Info:
www.glrea.org
Jul. 3-6, '08. Rothbury, Ml. Music festival. RE,
climate action, sustainable living. Info:
www. roth b u ryf estiva I .co m
West Branch, Ml. Intro to Solar, Wind & Hydro.
1st Fri. each month. System design & layout for
homes or cabins. Info: 989-685-3527 •
gotter@m33access.com •
www.loghavenbbb.com
MISSOURI
New Bloomfield, MO. Workshops, monthly
energy fairs & other events. Info: Missouri
Renewable Energy • 800-228-5284 • info@
moreenergy.org • www.moreenergy.org
MONTANA
Whitehall, MT. Seminars, workshops & tours.
Straw bale, cordwood, PV & more. Info: Sage
Mountain Center • 406-494-9875 •
www.sagemountain.org
NEW HAMPSHIRE
Rumney, NH. Green building workshops. Info:
D Acres • 603-786-2366 • info@dacres.org •
www.dacres.org
NEW MEXICO
Jun. 27-29, '08. Taos, NM. Taos Solar Music
Festival. Solar-powered music, food & displays.
Info: www.solarmusicfest.com
home power 125 /june & july 2008
Sep. 20-21, '08. Albuquerque. Solar Fiesta. RE
& EE exhibits & workshops. Info:
www.nmsea.org
Six NMSEA regional chapters meet monthly,
with speakers. Info: NM Solar Energy Assoc. •
505-246-0400 • info@nmsea.org •
www.nmsea.org
NEW YORK
Jun. 21-22, '08. New York City. Renewable
Energy Finance Forum. Info:
www.euromoneyenergy.com
NORTH CAROLINA
Aug. 22-24, '08. Fletcher, NC. Southern Energy
& Environment Expo. RE displays, exhibits &
presentations. Info: www.seeexpo.com
Beech Mt., NC. Western NC RE Initiative 2008
workshops: Jun. 20-21: Community-Scale
Biodiesel Production; Jul. 11-12: Domestic
Solar Water Heating; Aug. 27: PV & the
National Electric Code; Oct. 4-5: Microhydro.
Info: WNCREI • 828-262-7333 • wind@
appstate.edu • www.wind.appstate.edu
Saxapahaw, NC. Solar-Powered Home
workshop. Info: Solar Village Inst. •
336-376-9530 • info@solarvillage.com •
www.solarvillage.com
OHIO
Sep. 1, '08. Johnstown, OH. Ohio Green Living
Fayre. RE, sustainable building, alternative
fuels, food, music, kids stuff & more. Info:
jay@bluerockstation.com •
www.ohiogreenliving.org
OREGON
Jul. 25-27, '08. John Day, OR. SolWest RE Fair.
Exhibits, workshops, speakers, family day,
music, alternative transportation & Electrathon
rally. Info: EORenew • 541-575-3633 • info@
solwest.org • www.solwest.org
Cottage Grove, OR. Adv. Studies in Appropriate
Tech., 10-week internships. Info: Aprovecho
Research Center • 541-942-8198 • apro@efn.org •
www. apro vecho.net
PENNSYLVANIA
Sep. 20-21, '08. Kempton, PA. PA RE &
Sustainable Living Festival. RE, natural building
& sustainable ag; workshops, speakers,
exhibits, vendors, music & kids' activities. Info:
www.paenergyfest.com
Philadelphia Solar Energy Assoc, meetings.
Info: 610-667-0412 • rose-bryant@verizon.net •
www.phillysolar.org
RHODE ISLAND
Jun. 7, '08. Coventry, Rl. Sustainable Living
Festival & Clean Energy Expo. RE workshops,
vendors & music. Info: www.livingfest.org
TENNESSEE
Summertown, TN. Workshops on PV,
alternative fuels, green building & more. Info:
The Farm • 931-964-4474 •
ecovillage@thefarm.org • www.thefarm.org
TEXAS
Aug. 1-3, '08. Marathon, TX. Living With
Nature, Sustainable Living & Green Building
Festival. Lectures, workshops, tours & vendor
displays on eco-construction, off-grid living &
more. Info: LWN • 432-386-4257 • sowelo2000@
yahoo.com • www.livingwithnature.net
Sep. 26-28, '08. Fredericksburg, TX. RE
Roundup & Green Living Fair. Exhibits,
speakers & workshops on RE, green building,
green ag & EE. Info: www.theroundup.org
El Paso Solar Energy Assoc. Meets 1st Thurs.
each month. Info: EPSEA • 915-772-7657 •
epsea@txses.org • www.epsea.org
Houston RE Group, quarterly meetings. HREG •
hreg@txses.org • www.txses.org/hreg
VERMONT
Jul. 11-13, '08. Tinmouth, VT. SolarFest. Solar
powered music & RE festival. Info:
www.solarfest.org
WASHINGTON STATE
Jul. 18-19, '08. Shoreline, WA. Shoreline
Sustainable Living & RE Fair. Exhibitors &
speakers. Info: www.shorelinesolar.org
RE happenings
WISCONSIN
Jun. 20-22, '08. Custer, Wl. RE & Sustainable
Living Fair (aka MREF). Exhibits & workshops
on solar, wind, green building, alternative
transportation, energy efficiency & more.
Home tours, silent auction. Kids' Korral,
entertainment, speakers. Info: See MREA listing
below.
Custer, Wl. MREA '08 workshops: Basic, Int. &
Adv. RE; PV Site Auditor Certification Test; Veg.
Oil & Biodiesel; Solar Water & Space Heating;
Masonry Heaters; Wind Site Assessor Training
& more. Info: 715-592-6595 • info@
the-mrea.org • www.the-mrea.org
Amherst, Wl. Artha '08 workshops: Intro
to Solar Water & Space Heating System,
Installing a Solar Water Heating System, Living
Sustainably & more. Info: 715-824-3463 •
chamomile@arthaonline.com •
www.arthaonline.com
INTERNATIONAL
GERMANY
Jun. 10-11, '08. Munich. PV Industry Forum.
Solar developments exhibition & forum. Info:
Solar Promotion GmbH • 49-07231-58598-0 •
www.pvindustry.de
Jun. 12-14, '08. Munich. Intersolar 2008. Solar
developments exhibition & forum. Info:
www.intersolar.de
NICARAGUA
Jul. 21-31, '08. Totogalpa. Solar Cultural
Course. Lectures, field experience &
ecotourism. Info: Richard Komp • 207-497-2204 •
sunwatt@juno.com • www.grupofenix.org
Send your renewable
energy event info to
happs@homepower.com
Adjustable Permanent Magnetic
Brushless Alternator
25 - 30% more efficient than Hi Output Alternator
Marine Grade Construction throughout
Re-connectable Stator
Retrofittable on existing turbine
Manufactured by Lo Power
P.O. Box 1567
Redway, CA 95560
Hydro- Power for Home Use
www.homepower.corn
marketplace
HYDROELECTRIC SYSTEMS: Pelton
and Crossflow turbines or complete AC
systems for standalone or grid interconnect
operation. Site evaluation and equipment
selection assistance. Manufacturing home
and commercial size turbines since 1976.
Free brochure: Canyon Industries, PO Box
36HP, Deming, WA 98244, 360-592-5552.
Email: info@canyonhydro.com Web page:
canyonhydro.com • HP12502
FOLLOW THE SUN! Light seeking single
and dual axis solar tracker controls.
www.theanalogguy.com • HP12503
ECOMALL: The largest environmental
portal of earth-friendly companies and
resources. Renewable energy companies,
news and information, www.ecomall.com.
To advertise, call 845-679-2490. • HP12504
XXXXXXX UNI-SOLAR XXXXXXXX
XXXXXXX 64 Watts $359 XXXXXXX
M55 Siemens panels $225. Almost new
1500 AH AGM 12-volts $1800. TraceX
SW5548 $2850. Ex 2KW inverter SB $850.
Buy, sell New/Used. • 760-949-0505 •
HP12505
PORTABLE AND STANDBY GENERATORS
from Honda, Yamaha, Subaru, Kipor, and
More + Wireless Remote Start Available.
www.hayesequipment.com •
1-800-375-7767 • HP12506
NEMO DC SUBMERSIBLE WELL PUMPS:
$239 Postpaid. New! NEMOSOLAR
15A12/24V CHARGE CONTROL W/LVD: $56
Postpaid. Immediate Shipping Worldwide.
WWW.NEMOPUMPS.COM 1-877-684-7979*
HP12507
I AM A SOLAR WHOLESALER looking
for retailers to carry my solar electronic,
educational & hobby goods. Phone # (916)
486-4373. Please leave message. • HP12508
DC POWERED CEILING FANS: 12 & 24
volts: The Best in the World: RCH Fanworks •
info@fanworks.com www.fanworks.com
PH: 509-685-0535. • HP12509
EDTA RESTORES SULFATED BATTERIES.
EDTA tetra sodium salt, $1 6/lb. plus $6
S&H for 1st lb. plus $2 S&H for each
additional lb. Trailhead Supply, 325 E. 1165
N., Orem, UT 84057, (801) 225 3931, email:
trailheadsupply@webtv.net, info, at:
www.webspawner.com/users/edta. •
HP12510
HYDROELECTRIC TURBINES: Custom sized
runners 50W-500kW, 82-400mm diameter,
stainless investment castings and
molded plastic, from $120, site analysis
spreadsheets, www.h-hydro.com • HP12511
WANT TO LIVE RENT-FREE - anywhere
in the world? There are empty homes in
every state and country, and property
owners are looking for trustworthy people
to live in them as property caretakers
and housesitters! The Caretaker Gazette
contains these property caretaking/
housesitting openings in all 50 states
and foreign countries. Published since
1983, subscribers receive 1,000+ property
caretaking opportunities each year,
worldwide. Some of these caretaking
and housesitting openings also offer
compensation in addition to the free
housing provided. Short, medium and
long-term property caretaking assignments
are in every issue. Subscriptions: $29.95/
year. The Caretaker Gazette, 3 Estancia
Lane, Boerne, TX 78006. (830) 755-2300 •
www.caretaker.org • HP12512
HYDROS, P.M. BRUSHLESS DC units with
Harris housing and wheel. Up to 70%
efficiency. From $1350.
www.homehydro.com 707-923-3507 CA •
HP12513
RENEWABLE
ENERGY
The biggest sustainability event in the South!
Green Products for Sale
Renewable Energy
Green Building
Water Use & Reuse
Energy Efficiency
Organic Growing
Alternative Fuel Vehicles
ROUNDUP
& GREEN LIVING FAIR
Sept. 26-28, 2008 ■ downtown Fredericksburg/TX
Lectures ■ Exhibits
Demonstrations ■ Family Activities
Organic Food ■ Music
877-3ROUNDUP ■ email:Roundup@txses.org - WWW.TheRoundup.org
home power 125 /june & july 2008
SOLAR THERMAL BUSINESS FOR SALE
Well established, good income, growth
potential, in a beautiful area in the Pacific
Northwest. Will train the right person.
Contact: solar4sale@gmail.com •
HP12514
RE-MANUFACTURED JACOBS WIND
TURBINE 31-20kw model complete with
tower and UL508 inverter $26,500 O.B.O.
661-724-1488 Jason • HP12524
CONTAIN YOUR BATTERIES SAFELY with
vented HDPE box complete with welded
seams and removable lid. Custom sizes
available, UPS shippable.
radiantsolartech.com 707-485-8359 •
HP12515
LED bulbs from CCrane at discount
prices. Many styles available in 12V and
120V. radiantsolartech.com 707-485-8359 •
HP12516
LARGE GAS REFRIGERATORS 12, 15 & 18
cubic foot propane refrigerators. 15 cubic
foot freezers 800-898-0552 Ervin's Cabinet
Shop, 220 N County Rd. 425E., Areola, IL
61910* HP12517
OFFERING STOCK PASSIVE SOLAR HOME
BLUEPRINTS for building a beautifully
simple, cost effective, energy efficient
home. Steve Kawell 970-769-3904 •
www.durangosolarhomes.com • HP12518
ANYTHING SOLAR POWERED: A handy
website for information on energy-saving
products, green living tips, letters, opinions
and photos.
www.AnythingSolarPowered.com •
HP12519
JACOBS: (4) 32 VDC, (3) 10KW MACHINES.
MasterMinds battery charger or utility
intertie. Manuals, tools, parts. Rohn SSV
towers. 907-562-3832 •
afehr@uaa.alaska.edu • HP12520
GET HOT AIR OUT OF YOUR ATTIC! Solar-
Powered Attic Fans
www.southsideatticsolution.com
(317) 847-4546 * HP12421
BIODIESEL PROCESSORS - High quality,
low price, 15 to 40 gallon capacity in one
garage sized unit, technical support. Visit
www.parmabiodiesel.com • HP12522
TAB RIBBON.COM.- We offer tab and bus
ribbon for building solar panels. Several
sizes and compositions including: 62/36/2
silver-bearing, 60/40 and others. Small and
large quantities available. We stock solder
of various types as well. Please visit our
websites for the finest in U.S.A made flat
wire, www.tabribbon.com •
www.solar-underground.com •
www.dbsolar.com • HP12523
SOLAR POWERED RETREAT in
beautiful Nelson County, VA., close
to Charlottesville. $315,000.00. More
information: www.greenhomesforsale.
com, listing #18181 in Howardsville, VA •
HP12525
UNIQUE LAKEFRONT LIVING ON THE
OREGON COAST! Off the grid community
in a spectacular location on Booth Island
in Siltcoos Lake. Choose from 2 custom
homes and 4 large parcels. Virtual tour
at www.boothisland.com. Call today
541-999-2336 * HP12526
FOR ALL YOUR OFF GRID NEEDS .
Panels, Controllers, Inverters & Batteries.
AERMOTOR water pumping windmills,
new & vintage, parts & supplies. KOHLER
LP 8.5, 12 & 17 kw generators.
www.timeforsolar.com. (970)209-4764 •
HP12527
Marketplace Advertising
Rates: $2.50 per word. $50 minimum per
insertion, paid in advance of publication.
Submit your ad to marketplace@
homepower.com or call 800-707-6585.
Keynote Speaker:
Greg Pahl
Author of
“The Citizen-powered
Energy Handbook”
2008
Grant County Fairgrounds
John Day, Oregon
541 - 575-3633
info@solwest.org
www.solwest.or g
Neighbors,
RENEW/ABL
3ft.
m -iM-
MW
Tf&l
EjWTHTC'T*
www.homepower.corn
installers directory
Experienced renewable energy professionals install high-performance, code-compliant systems, and will
offer you service and support after the sale. As with any home improvement project, request references
and certifications, and compare bids before you buy To get your business listed in Home Power's
installers directory, e-mail advertising@homepower.com or call 541-512-0201.
Alabama
Affordable Solar Hot Water and Power installs
in Alabama and Georgia, solar hot water, pool heating,
and electricity. We consult and certify for, energy efficiency,
green building, new construction or existing buildings, for
tax credits, to increase value, comfort and air quality The
most reliable products, at a fair price, www.asolarpro.com,
asolarpro@gmail.com phone 334-828-1024.
Alaska
ABS Alaskan, Inc. Anchorage - Fairbanks - Renton,
WA Battery systems. Remote power systems, RE systems.
OEM design and fabrication. Consultation & design, sales,
installation, & service for solar, wind, hydro, and hybrid
components and systems since 1989. Web - www.absAK.com.
Toll free 800-235-0689 or 800-478-7145, email jim@absAK.com.
Arizona
C&R
SOLA ft
C & R Solar Quality design, sales and installations of
solar/ wind power systems to meet your application. Serving
northwest Arizona since 1989 for remote homes and grid
tied systems. Living off grid since 1980. We achieve customer
satisfaction with over 25 years of experience in renewable
energy. ROC135882. 928-757-7059.
California, cont.
Carlson Solar, has been serving Southern CA since
1988. We are a licensed, bonded, and insured solar-electric
C A n L so hr installation company, specializing in both grid-tie and off-grid
Sfl La h systems. We are NABCEP certified and take great pride in our
excellent customer service. Saving the environment one house
at a time. Call toll-free 1-877-927-0782 or visit us at
www.carlsonsolar.com
CcbaFt
Cobalt Power Systems Inc. is a full-service, licensed
installer of PV systems in the SF Bay Area. We offer free
consultations, detailed proposals, professional system design
by an electrical engineer, expert installations, and competitive
pricing. We handle all the paperwork for the client, and we
oversee all inspections. Please contact us at 650-938-9574 or
www.cobaltpower.com.
Electron Connection Licensed in CA and Oregon.
NABCEP Certified installer. Serving northernmost California
and southern Oregon. PV, wind, microhydro installs.
800-945-7587 email: bob-o@electronconnection.com,
www.electronconnection.com CA Lie. #613554
EV Solar Products, Inc. Licensed solar professionals
since 1991. We design and install solar electric and hot
water systems for grid-tie and remote homes. Visit our retail
showroom just north of Prescott at 2655 N US Hwy 89. Chino
Valley, AZ 86323 ROC Licenses: 129793/118299. 928-636-2201.
Empower Energy, Southern California. We design,
sell, install, & service high quality residential & commercial
|_ solar electric generation systems. Specializing in grid-tied
enerqy ER and remote stand-alone systems. Make renewable energy a
responsible and cost-effective part of your home or business.
Free project estimate 800 494-2366 empowerenergy.net info@
empowerenergy.net. Licensed since 1995, #711993
Generator Solar & Wind Power Systems Design,
Sales, installation & maintenance. Off-grid & grid-tied, prime
■G.SlW. power or back-up. Complete systems, hybrid systems, or sub
*lrv;i likllUk' ' systems & components. We can do it. Covering all of Arizona
& dedicated to helping all present & potential customers.
License # ROC203166, 928-300-4067, altpwrsys@hotmail.com
Independent Energy Systems, Serving the
Santa Cruz /Monterey Bay Area. We specialize in design,
installation and sales of residential/commercial PV systems.
■-.' 1 ^ r p\‘ ■ ■ j f.- j Our mission is to provide our friends in the community an
fkj i itIy i'v iti lh'i opportunity to become part of the future in renewable energy.
We are based in Santa Cruz, we love what we do and it shows
in our work! Ph: 831-477-0943 or visit www.iesolar.com
IDC
Solar
IDC Solar Exclusive products like the Guy-wireless
Towers, Modular Wiring Unit and Automatic Battery
Watering System for code compliant, worry-free hybrid
renewable energy systems. We install locally or nationally.
Complete licensing for all residential and commercial devices.
Skystream turbines & towers up to 50' now available.
928 636-9864 or idcllc@northlink.com • www.idcsolar.com
I I +. I 1 .!
■ I llikll
Arkansas
Rocky Grove Sun Company has been serving NW
Arkansas and the surrounding region since 1986. Design,
installation and consultation with two NABCEP certified
installers: Flint Richter and Jimis Damet with over 35 years
combined experienced in PV stand alone & grid-tied, wind and
hydro. Located in the heart of NW Arkansas Ozarks. Contact us
at 479-665-2457 or info@rockygrove.com www.rockygrove.com
California
Acro
ELECTRIC
Acro Electric is a full service electrical contractor
specializing in solar power. We provide turn-key solutions
for PV, standby power, LED lighting, and more. Approved by
the League of California Homeowners (www.homeowners.
org) & Better Business Bureau (www.midcalbbb.org). Free site
analysis & brochure. (866)711-ACRO • www.acroelectric.com
Quality installations backed by 32 years electrical experience.
Michael Symons Electric, C-10 licensed electrical
contractor. NABCEP certified installer. We design, sell, install
Symons & service both commercial & residential Photovoltaic systems
■->1 - - since 1982. We specialize in grid-tie and stand alone off grid
CIcCllIC systems including solar wells. We are located in East San
Diego County serving Southern California and Baja California
Norte. Ph: 619-468-3277 or E mail symonselectric@aol.com
Offline Independent Energy Systems, Since 1983.
An electrical contracting co., we specialize in utility intertie
P^/TIn5^
(with state rebate & net metering) & off grid systems. Owned
& operated by Don & Cynthia Loweburg in Central CA East
of Fresno. Don Loweburg NABCEP Certified Installer. POB
231, North Fork, CA. 93643, (CA lie# 661052) ph 559-877-7080,
fx 559-877-2980, ofln@aol.com www.psnw.com/~ofln
REVCO Solar Engineering, Inc. has been serving
Orange County, LA County and The Inland Empire since
1977. We specialize in Solar Pool Heating, DHW and Solar
Electric PV systems. REVCO is actively involved with the
League of California Homeowners, the American Solar
Energy Society and CALSEIA. B/C-46 Lie# 387219.
www.revcosolar.com 800.274.3638
Apex, Apex Solar Specializing in residential off grid and
remote commercial solar power. We provide system design,
sales and turn key installation. For do-it-yourselfers, we
can help with wiring diagrams and 10+ years of off grid
experience. Licensed contractors in California call us toll free
at 888 782-0706 or visit us at www.apxsolar.com
Solar Wind Works specializes in consultation, sales,
design, service, & installation of complete RE systems.
US Distributor for Proven Wind Turbines. We supply
all components. Grid-connected or grid-independent.
Truckee, CA 530-582-4503, 877-682-4503, NABCEP
Certified Installer. CA Contractor's Lie # 796322 chris@
solarwindworks.com, www.solarwindworks.com
home power 125 /june & july 2008
installers directory
Canada
Energy Alternatives has been serving Canadians for
over 20 years. A licensed electrical contractor (BC Lies #
86683) with professional installers throughout Canada. Expert
consultation & design services, turn-key installed systems
or DIY packaged system kits. Extensive inventory for fast
delivery. Visit www.EnergyAlternatives.ca, Call
1-800-265-8898. Canadian dealer inquiries welcome.
Natural Power Products is Ontario's leading supplier,
retailer and installer for solar, wind, domestic hot water, and
other renewable energy technologies. Complete design and
turn-key packages for home, cottage, rural, businesses etc. All
applicable codes are adhered to and inspected by ESA.Visit:
www.npp.ca e-mail: info@npp.ca call: 519-504-1600
Colorado
Namaste Solar Electric Inc.,Smart. Simple. Sustainable.
Namaste Solar brings clean, reliable, & affordable renewable
energy to homes, businesses, & nonprofits in Denver /Boulder.
A values-based, 100% employee owned company committed
Ninmte Soiih * 0 maintaining the highest standards of environmental
— p f*£ 1 1 1 r • stewardship, customer satisfaction, community philanthropy, &
professional integrity. (303) 447-0300 • www.namastesolar.com
Solar Solutions Ltd. provides photovoltaic, wind &
hybrid power systems & components for stand alone systems,
grid tied, RV's & remote water pumping. Committed to
providing the highest quality service & customer satisfaction.
A proud member of Colorado SEIA and a lifetime member of
the Colorado RE Society and ASES. Xantrex Certified Dealer.
888 44solar or 888-447-6527 www.solarsolutions.com
Florida
Allsolar Service Company Inc., Allsolar is a Florida
based design-build solar contracting firm specializing in solar
pool heating, solar water heating, and solar electric systems
I > LSOLAH for residential, commercial and industrial applications. Free
Estimates. Harnessing the sun's energy since 1974.
www.allsolarflorida.com l-888-6solar-l CVC056657 Joshua
Bessette
ECS Solar Energy Systems (tel) 352-377-8866
www.ECS-solar.com f tom@ECS-solar.com We service FL, the
Caribbean and the Southeastern U.S. FL's first solar contractor
since 1977. Solar pool heating, hot water, and electric systems
-commercial & residential. Solar lie. # CVC056643 Florida
state certified for "grid-connected" systems. Contact us now
to receive a free solar informational booklet.
Michael Fink Electrical Inc. licensed/insured/
RE SOLAR bonded.electrical contractor specializing in design, sales,and
AND quality installation services for grid-tie PV systems and
GENERATOR ^ ome standby generators, serving Lee and Collier counties in
TOM southwest Florida. Dealer for Guardian generators, Aeesolar,
•V.UI I Sunwize. visit www.resolarandgenerator.com 239-218-2280,
239-282-5721, erl3012717
Maine
Benchmark Solar PV and solar thermal solutions from
design through construction for residential and commercial
buildings. NABCEP PV Installer's Certification; Master
3 Electrician licensed in Maine, NH, and MA. Master Plumber/
^ H Heating license. Grid-tie, off-grid, hot water and space
heating applications. We also serve the island communities.
Call 1-800-9SOLAR1 (976-5271) www.benchmarksolar.net
Maryland
Standard Solar Inc., serving Montgomery and Frederick
Counties, Maryland, Northern Virginia, and Washington, DC.
^TAnDAfTO since 2004. Specializing in residential solar electric installations.
^ A|j A ^ Visit our Website: www.standardsolar. 202 Perry Parkway
#7, Gaithersburg, Maryland, 20877. Tel. 301-944-1200; email:
metrodc@standardsolar.com
Massachusetts
Nexamp, Inc. is a turnkey, renewable energy integration
and full spectrum energy solutions company serving
rt.jvh.HH homeowners, businesses and governments in Massachusetts,
nexjfimp Our offerings include site feasibility assessments, business
modeling, system design, permitting, installation and
maintenance services. Learn more about our Veteran operated
company at 978-688-2700 or at Nexamp.com
Michigan
Backwards to the Future Ltd, installing, designing
and supplying solar equipment since 1986. OEM supplier of
evacuated tube heat pipe technology for DHW & hydronic
heating. Systems building integration by joint venture with
registered architect. State licensed residential builder & solar
mechanical contractor. POB 409 Fennville MI 49408
tel: 269-236-6179 email: info@BTFsolar.com www.BTFsolar.com
SACKETT
BRICK
Fireplace
Design
Sackett Brick is the mid-west distributor for Tulikivi
masonry heaters. We have 10 dealers /installers in 8 states:
Indiana, Illinois, Iowa, Michigan, Minnesota, Missouri, Ohio &
Wisconsin. Tulikivi masonry heaters are a clean and efficient
way to provide heating, cooking and baking with very little
wood. Visit www.sackettbrick.com or call 800-848-9440.
DEALER INQUIRIES WELCOME
Montana
Oasis Montana Inc. designs and sells renewable energy
power systems in North America and also offers efficient and
LP gas appliances. Call to discuss your project. 877-627-4768
or 4778. Web sites: www.oasismontana.com, www.grid-tie.
com, www.PVsolarpumps.com, www.LPappliances.com,
www.eco-fridge.com, E-mail:info@oasismontana.com
Nevada
Alternative Energy Solutions, Reno, Nevada. We
design, sell, install and service PV, wind, off grid and grid tie
RE systems, Nevada State Licensed and Bonded Contractor,
NABCEP PV Certified Installer. Xantrex / Trace Authorized
Service Center, Xantrex Certified Dealer, Outback Factory
trained field service technicians and Certified Uni-Solar field
laminate installer. 775-857-1157 toll free 1-866-491-SOLR
SCI
Solar-Fit is one of Florida's oldest active solar contractors.
Established in 1975, International Sun Protection, Inc. (dba
Solar-Fit), has helped over 8,000 families and businesses
"Plug into the Sun". Call (386) 441-2299 for FREE information
on solar electric, solar pool and solar hot water systems, and
solar attic fans, or visit us on the web at www.solar-fit.com
State Certified Solar Contractor #CVC56690.
Idaho
Creative Energies Eastern Idaho's premiere full-service
RE company. Solar & wind power for remote cabins, homes &
ranches, utility grid-tied solar & wind power, solar hot water
& heating, solar water pumping & passive solar home design.
We custom design a system that fits your needs & budget.
Trace certified dealer. Phone/fax: 208-354-3001 toll free
866-332-3410 info@cesolar.com • www.cesolar.com
Kentucky
Solar Energy Solutions offers full-service design,
consultation, and installation for renewable energy projects
in KY, OH, IN, and surrounding states. We install off grid
fr Seh-Ewa Inh to on-grid — residential to industrial. Employees maintain
NABCEP PV and Solar Thermal certifications. Fully licensed
and insured. Visit www.solar-energy-solutions.com or call
859-312-7456.
Solar Wind Works specializes in consultation, sales,
design, service, & installation of complete RE systems.
US Distributor for Proven Wind Turbines. We supply all
components. Grid-connected or grid-independent. Truckee,
CA 530-582-4503, 877-682-4503, NABCEP Certified Installer.
NV Contractor's Lie # 59288.
chris@solarwindworks.com, www.solarwindworks.com
New Mexico
Positive Energy, Inc. High quality residential and
commercial solar power systems. Grid-tied and off-grid
systems. Licensed, bonded, and insured electrical contractor
serving NM since 1997. Three owners are NABCEP Certified
Installers and live on solar power. Company is carbon-
neutral. References on Findsolar. 505-424-1112.
info@positiveenergysolar.com www.positiveenergysolar.com
Solar Ray SolarRay.com Complete Solar Electric Systems
for off-grid, grid-tie, and grid-tie with battery backup. Turn
key installations to DIY. Also offer Electric Vehicles. Licensed,
bonded, & Insured Electrical contractor. 2 NABCEP certified
installers on staff. Serving New Mexico and Colorado for over
10 years, ray@solarray.com, (575) 737-9553, www.solarray.com
www.homepower.corn
131
installers directory
New York
Solar & Wind FX Inc. NY's only Off-grid Design &
Training Center, where a client can see the latest RE & Green
building technologies. A family owned, full service company
focusing on Western NY that provides site evaluation, design,
installation & the all important, service after the sale. Member
of NESEA & NYSEIA, SEI alumni & a NYSERDA installer.
585-229-2083, solarandwindfx.com
North Carolina
Argand Energy Solutions is an experienced, full-
service provider of solar PV, solar hot water, solar pool
j heating, and wind system design and installation, serving
t|W;P residential, commercial, and government customers in NC,
SC, GA, southeast; licensed and insured, for more information
visit www.argandenergy.com or call (704) 583-9295,
info@argandenergy.com.
South Carolina, cont.
0 Suns tore Solar Full service solar systems integrator,
serving Carolinas & Georgia for 30 years. Proud to serve
the community by providing the highest quality product
and excellent customer service. Provide all services needed
from consultation/ design to installation on all types of Solar
Systems. 3090 South Hwy 14, Greer, SC 29650 864-297-6776,
www.sunstoresolar.com, info@sunstoresolar.com
Utah
Alternative Power Systems, Inc. is Southern Utah's
premier Designer & Installer of renewable energy systems. We
provide design, sales, installation & service of Solar Power,
Solar Hot Water, Wind & Back-up Generators. We are the
region's only NABCEP certified. We are insured & licensed
in Utah #6259909-5501 And Nevada #0068796. Compare our
prices, www.apssolar.com 435-586-9181
Sundance Power Systems, Inc. Serving the Southeast
since 1995 with high-performing residential & commercial
renewable energy systems, including SHW & radiant floor
heat, solar, wind, & micro-hydroelectric. Providing value with
over 13 years, thousands of installations, & millions of kilowatt
hours of experience to serve you! Phone: 828 645-2080
info@sundancepower.com, www.sundancepower.com
Ohio
REpower SOLUTIONS: Northeast Ohio's renewable
energy provider for home & business. Design & professional
installation of solar PV & wind systems. Home energy ratings
& small commercial energy audits. Erika Weliczko - NABCEP
Certified Solar PV Installer, OH LIC #44844, Certified Home
Energy Rater WEB: www.repowersolutions.com, EMAIL:
power@repowersolutions.com PHONE: 216-402-4458
Solar Unlimited Energy & Homes, Inc. Serving
Southern Utah, Eastern NV and Northern AZ since 1998.
Providing sales, service and installation of all your alternative
energy needs, including PV, Wind, Net-Metering, Off-Grid,
Batteries and Generators. We are also an Authorized Xantrex
Service Center. Licensed & Insured. Call toll free 866-solar99
or visit www.solarunlimited.net
Vermont
Independent Power LLC Serving Northern Vermont
and New Hampshire with PV design, sales and installation.
NABCEP certified owner David Palumbo has built over 300
off-grid and grid tied systems since 1988. Outback Certified
Dealer. 462 Solar Way Drive, Hyde Park, VT 05655
www.independentpowerllc.com 1-802-888-7194
Third Sun Solar & Wind Power, Ltd. Ohio's
premier solar and wind power contractor. Complete design
and installation of utility tied or off-grid systems for OH
and surrounding states. Serving commercial and residential
customers. NABCEP Certified PV Installer committed to
excellent customer service & the highest quality systems.
www.third-sun.com 740 597-3111.
Oregon
Cascade Sun Works, a leading renewable energy
contractor in Central Oregon, offers innovative products and
cost-effective engineered solutions suited to your energy
needs. We provide Solar Thermal and PV installed systems,
pre-packaged kits, service and engineering. Licensed and
certified. Visit www.sun-works.com or contact us at (541)
548-7887 CCB #151227
Electron Connection Licensed in CA and Oregon.
NABCEP Certified installer. Serving northernmost California
and southern Oregon. PV, wind, microhydro installs.
800-945-7587 email: bob-o@electronconnection.com,
www.electronconnection.com OR CCB# 149724
Vermont Solar Engineering has provided the
finest in renewable energy throughout New York and New
England, since 1991. We design, install, and support solar
electric, wind electric, and solar hot water systems.
— K. Herander, NABCEP™ certified installer. Xantrex Certified
Dealer. NYSERDA eligible installer. Vermont Solar and Wind
Partner, www.vermontsolar.com 1-800-286-1252
Virginia
Dunimis Technology Inc. Providing alternative
energy systems since 1992. NABCEP certified solar
technicians on staff. We specialize in the more demanding
upscale off-grid residential & commercial installations.
Installations completed in ID, TX, PA, NJ, NC, VA, and WV.
PO. Box 10, Gum Spring, VA 23065, Phone 804-457-9566,
jryago@netscape.com, www.pvforyou.com
Washington
P H H Cl V
Seraphim Energy, Inc. Full service electrical contractor
serving the Columbia River Watershed. We specialize in on
and off grid wind, sun and water powered systems, meeting
all your design, installation and procurement needs. Seraphim
Energy: your power provider. WA#SERAPEC971MG/OR
CCB#175837 • 1-800-265-6288 www.seraphimenergy.com,
re@seraphimenergy.com
A
Mr. Sun Solar
Mr. Sun Solar Since 1980, the Northwest's leading
solar installer. Over 1,900 projects including solar hot water,
solar pool heating, solar attic fans, and on- and off-grid PV
systems. Dealer for Sol-Reliant(TM), The Solar Water Heating
System Built to Last - OG-300 and Bright Way(TM) approved.
Phone: (888) SOL-RELY (888-765-7359). www.MrSunSolar.com
and wwwSolReliant.com.
SolarWind Energy Systems, LLC PO. Box 1234,
Okanogan, WA 98840 509-422-5309 www.solar-wind.us WA
Cont. # SOLARES983RQ. Serving Eastern WA & Northern
ID grid-tied & off-grid RE systems. Solar PV, wind, solar hot
water, remote stock watering. Design, installation, service,
maint. Solar Energy International (SEI) trained. Lie. &
bonded. bclark@solar-wind.us or jmartin@solar-wind.us
Trinity Electrical Contractors Corp. A full service
licensed electrical contractor specializing in PV and Wind
system design and installs. Serving all of Central Oregon. We
are proud to be an Energy trust of Oregon Trade Ally. Call
541-923-0556 or visit us at www.trinityelectric.org
South Carolina
Argand Energy Solutions is an experienced, full-
service provider or solar PV, solar hot water, solar pool
j heating, and wind system design and installation, serving
residential, commercial, and government customers in NC,
SC, GA, southeast; licensed and insured, for more information
visit www.argandenergy.com or call (704) 583-9295,
info@argandenergy.com.
Western Washington Solar designs & installs solar
Air fa electric, solar hot water, solar space heating & wind power
systems for residential & commercial clients throughout
9 Washington. Renewable energy will save you money, add
value to your home or business, & reduce greenhouse gas
mF emissions. 360-319-6273, www.westernwashingtonsolar.com,
9.™ email: info@westernwashingtonsolar.com
Wyoming
Creative Energies Wyoming's premiere full-service RE
company. Solar & wind power for remote cabins, homes &
ranches, utility grid-tied solar & wind power, solar hot water
& heating, solar water pumping & passive solar home design.
We custom design a system that fits your needs & budget.
Trace certified dealer. Phone/fax: 307-332-3410 toll free
866-332-3410 info@cesolar.com • www.cesolar.com
home power 125 /june & july 2008
"E* r
Your Choice...
in Renewable Energy Education
www.solarenergy.org
r f
\
m i I
IPlUfi^TB
Hands-on Workshops & Online Courses
-PV Design & Installation
-Advanced PV-Design Criteria & NEC
-Grid-tied Photovoltaics
'Women's PV Design & Installation
-PV Lab Week
-Building for the Future
-R.E. for the Developing World
-Solar & Radiant Heating
-Strawbale Construction & Plasters
-Natural Home Building
-Solar Water Pumping
-Solar Hot Water
-Micro Hydro
-Wind Power
. &
SEI Online
-PV Design Online
•Advanced PV Online
Design Criteria & NEC
•Building for the Future Online
Sustainable Home Design
y
Solar Energy International
PO Box 7 1 5 Carbondale, CO 8 1 623
39845 Mathews Lane Paonia, CO 81428
970-963-8855 *fax 970-963-8866
sei@solarenergy.org
Don't miss the premier
energy education event
in the nation!
Featuring
4^ Annual Clean Energy Car Show
Green Home Pavilion Newin ' a8
KtainahlpTahlpc Wewinoe
advertisers index
A&C Green Energy, www.acgreenenergy.com 109
AAA Solar Supply, www.aaasolar.com 104
Abraham Solar, www.abrahamsolar.com 122
ABS Alaskan Inc., www.absak.com 26
AEE Solar, www.aeesolar.com 5
Affordable Solar Group, www.affordable-solar.com 24/25
Alternative Energy Store, www.altenergystore.com 71
Alternative Power & Machine, www.apmhydro.com Ill
Apex Solar, www.apxsolar.com 125
Apollo Solar, www.apollosolar.com 89
Apricus Solar Co. Ltd., www.apricus.com 53
APRS World LLC, www.winddatalogger.com 125
ART TEC, www.arttec.net 117
Artha Sustainable Living, www.arthaonline.com 117
BackHome Magazine, www.backhomemagazine.com 81
Backwoods Solar Electric Systems, www.backwoodssolar.com 89
Blue Sky Energy Inc., www.blueskyenergyinc.com 91
Bogart Engineering, www.bogartengineering.com 90
Brand Electronics, www.brandelectronics.com 122
Butler Sun Solutions, www.butlersunsolutions.com 110
BZ Products, www.bzproducts.net 1 17, 124
C Crane Co., www.ccrane.com 125
Careers in Renewable Energy, www.pixyjackpress.com 113
CMS Magnetics, www.acgreenenergy.com 109
Conergy Inc., www.conergy.us 3
DC Power Systems Inc., www.dcpower-systems.com 65
Efficient Radiant Systems LLC, www.efficientradiant.com 117
Electric Auto Association, www.eaaev.org 1 13
Electro Automotive, www.electroauto.com 104
Electron Connection, www.electronconnection.com 72
Energy Conservation Services, www.ecs-solar.com 80
Energy Systems 8t Design, www.microhydropower.com 1 19
Energy Wise Solutions, www.energywisesolutions.net 122
Exeltech, www.exeltech.com 105
Fronius USA LLC, www.fronius-usa.com 10/11
Fullriver Battery USA, www.fullriverdcbattery.com 27
Gorilla Electric Vehicles, www.gorillavehicles.com 125
Green World Biofuels, www.greenworldbiofuels.com 122
GroSolar, www.grosolar.com IFC, 35
Harris Hydro, 707-986-7771 127
Home Power Inc., www.homepower.com 64
Hydrocap Corp., 305-696-2504 110
Hydroscreen Co. LLC, www.hydroscreen.com 125
Innovative Solar Inc., www.scsolar.com 109
Intersolar US, www.intersolar.us 73
Jan Watercraft Products, www.janwp.com 125
Kaco Solar Inc., www.kacosolar.com 44
Liberty Enterprises Inc., www.iloveebikes.com 122
Living With Nature Festival, www.livingwithnature.net 122
Lorentz GMBH & Co. KG, www.lorentzpumps.com 15
Magnum Energy, www.magnumenergy.com 17
Midnite Solar Inc., www.midnitesolar.com 28
Mitsubishi Electric, www.mitsubishielectricsolar.com 36
MK Battery, www.mkbattery.com 79
Morningstar Corp., www.morningstarcorp.com 79
N. Am. Board of Cert. Energy Practitioners, www.nabcep.org 119, 123
New Society Publishers, www.newsociety.com Ill
Northern Arizona Wind & Sun, www.solar-electric.com 110
Northwest Energy Storage, www.solaronebatteries.com 105
Offline Independent Energy Systems, www.psnw.com/~ofln 114
OutBack Power Systems, www.outbackpower.com 8/9
Phocos USA, www.phocos.com 114
RAE Storage Battery Co., 860-828-6007 124
Renewable Energy and Sustainable Living Fair, www.the-mrea.org .... 134
Rheem Water Heaters, www.solahart.com 37
RightHand Engineering, www.righthandeng.com 124
S-5!, www.s-5.com 1 19
Samlex America Inc., www.samlexamerica.com/solar 103
San Juan College, www.sanjuancollege.edu/reng 123
Sanyo Energy USA Corp., www.us.sanyo.com BC
Silicon Solar, www.siliconsolar.com 2
Simmons Natural Bodycare, www.simmonsnaturals.com 124
SMA America Inc., www.sma-america.com 23
Solar Converters Inc., www.solarconverters.com 80
Solar Depot Inc., www.solardepot.com 20/21
Solar Energy International, www.solarenergy.org 133
Solar Pathfinder, www.solarpathfinder.com 110
SolarFest, www.solarfest.com 123
Solargenix Energy LLC, www.solargenixchicago.com 119
SolarH20t LTD, www.solarhotusa.com Ill
SolarWorld California, www.solarworld-usa.com 29
Solectria Renewables, www.solren.com 90
Solmetric Corp., www.solmetric.com 103
Sol-Reliant www.solreliant.com 91
SolWest RE Fair, www.solwest.org 129
Southwest Solar, www.southwest-solar.com 124
Southwest Windpower, www.windenergy.com 13
Staber Industries Inc., www.staber.com 118
Steca GmbH, www.stecasolar.com 109
Stiebel Eltron Inc., www.stiebel-eltron-usa.com 55
Sun Frost, www.sunfrost.com 118
Sun Pipe Co. Inc., www.sunpipe.com 115
Sun Pumps Inc., www.sunpumps.com 81
Sun Spot Solar, www.sssolar.com 118
SunDanzer, www.sundanzer.com 103
SunEarth, www.sunearthinc.com 114
Suntech Power Holdings Co. Ltd, www.suntech-power.com 45
SunWize, www.sunwize.com 19
SunXtender, www.sunxtender.com 4
Surrette Battery Company Ltd, www.rollsbattery.com IBC
SustainableChoice.net, www.sustainablechoice.net 115
Texas RE Roundup 8t Green Living Fair, www.theroundup.org 128
The Carbon Free Home, www.chelseagreen.com 81
Thermomax, www.solarthermal.com 126
Trina Solar Ltd., www.trinasolar.com 63
Trojan Battery Co., www.trojanbattery.com 54
U.S. Battery, www.usbattery.com 102
UniRac Inc., www.unirac.com 88
Wattsun (Array Technologies Inc.), www.wattsun.com 115
Western NC Renewable Energy Initiative, www.wind.appstate.edu ....115
Wiley Electronics LLC., www.we-llc.com 118
WindMax Energy, www.magnet4less.com 124
Windstream Power LLC, www.windstreampower.com 124
Xantrex, www.xantrex.com 1
XC3 International LLC, www.xc3solar.com 114
Zephyr Industries Inc., www.zephyrvent.com 124
Zomeworks Corp., www.zomeworks.com 123
For easy online access to advertisers, visit www.homepower.com/resources/advertisers
www.homepower.corn
People
Who: Meg Thomas
Where: Ashland, Oregon
When: 2004 to present
Why: Because it's never too late to do
your part
lE
Meg Thomas is a grandmother — and at first glance, a
pretty conventional one. She goes by "Mammie" or
"Nanna," and wears her hair in silver curls — but don't
be fooled by her typical appearance. This church-going
grandmother of seven is a feisty, forward-thinking one.
Other grandmothers might drive
a late-model Cadillac or luxury
Town Car. Not Meg. At 85, she
cruises around in a Toyota Prius.
"It's such a neat car. Not only do I
feel 'with-it,'" she laughs, "driving
a hybrid or electric vehicle is the
right thing to do."
Thomas is proud that her car
stands out in town and even more
pleased that she can drive up to
54 miles on a gallon of gasoline.
Her commitment to conservation
doesn't end with her wheels,
though. When she's not doting
on her grandchildren or great
grandchildren, playing bridge, or
tending to her vegetable garden,
she's counting the kilowatt-hours
generated by the solar-electric
system that she had installed on
her home in 2004.
Thomas got serious about
renewable energy a few years
ago — after downsizing to a modest,
single-story home "to save her
bones and save energy." She
heard that the city offered a variety
of services and incentives to help
residents improve the efficiency of their homes. "It was easy,
she says. "I just made a few calls, and before I knew it, I had
guys in here using blowers and all sorts of gadgets to find all the
air and energy leaks."
A woman ahead of her time, Meg
Thomas invested in PV, energy
efficiency, and efficient transportation —
for the sake of future generations.
grandchildren at holidays and birthdays,
I decided to give them the gift of solar
energy and help make the world a better
place for them."
Like many people living on savings and
social security, Meg stretches every dollar
with coupons and senior-citizen discounts.
When it came to investing in energy, she
was equally thrifty — taking advantage
of city, state, and federal incentives
that covered more than half of the cost
associated with the efficiency upgrades
and PV system.
Meg paid roughly $10,000 for the PV
system, which generates about 3,300
KWH of electricity annually. Any power in
excess of her needs is sold back to the grid. During the summer,
her meter spins backward, earning her roughly $7 per month.
"Even in the darkest months of winter, I have the lowest electric
bill of all my friends," she says.
The energy audit showed that her 1975 home would require
several upgrades to achieve optimal efficiency. Meg didn't
hesitate. She hired professionals to replace the heating ducts,
install double-pane windows, and amend the insulation. But
she didn't stop there. Next came a new roof and a batteryless,
grid-tied 3.3 KW solar-electric system — complete with 15 Sanyo
photovoltaic (PV) modules that feed into a Fronius IG3000 inverter.
Although Meg wasn't concerned if the system paid for itself in
her lifetime, rebates and incentives add up for a quick payback —
about 10 years. But for her, this wasn't the point. "Nothing that
I've ever spent money on has paid me back, so why should that
matter now? It's an investment in our planet," she says. "People
always ask, 'Do you think the system will pay for itself?' I say, 'I
don't care if it pays me back. It will pay the world back.'"
"We waste so much and have too much," Thomas says. Robert Plain (bobplain@yahoo.com),
"Instead of buying pointless gifts for my grandchildren or great with Kel| y Davidson (kelly.davidson@homepower.com)
home power
125 /June & july 2008
Shawn Schreiner (2)
b [j)qrj££)
7 25274 78082 2
OUR ULTIMATE GUIDE TO SOLAR WATER HEATING SYSTEMS
j .'Mike arid'Joanne Young
_ -trade their'Vermont heating
!■ ■ m
bills for sustainable'sailing in
k " She Caribbean each winter.
PUMP
WATER
with Sunshine
Rainwater
Harvesting
HOW-TO
Creating a
Net Zero-Energy
Home or Business
Get Your Geek On:
PV Array Sizing
Microhydro
Pipeline Design
groSolar
What
the
World
Needs.
NOW
A Full Service Solar Distributor,
groSolar Delivers...
0 Largest product selection from warehouses
across North America
0 Business and technical training and field assistance
0 Turnkey and custom solutions
0 Solar energy industry advocacy
Visit Us At the Next Show Nearest You...
Midwest Renewable Energy Fair
6/20
Custer, Wl
Sol West Fair
7/25
John Day, OR
Solar Power 2008
10/13
San Diego, CA
CanSIA Solar Conference 2008
12/7
Toronto, ON, CN
Co to groSolar.com/events for more
information
Become a groSolar partner today
Solar Electric O Solar Hot Water O Solar Air Heating
8oo GO SOLAR (800.467.6527) groSolar.com
OUR STANDARD LABEL
Rolls has been producing premium batteries
specifically designed for the renewable energy market since 1 984.
That’s why those who can’t afford to go without power know they
can’t afford to trust anyone else.
BATTERY ENGINEERING
Superior Cycling | Dual-Container Construction | Widest Range of Specs
HH 1 Largest Liquid Reserves | Easiest to Install | Longest Life Span | Premium Warranties
T. 1.800.681.9914 E. sales@rollsbattery.com www.rollsbattery.com
Up VJSJ Wjm pa/ Ssiija/a
Depends on system design, location & albedo
HIT® Double
SANYO'S new HIT® Double bifacial solar panel captu^WP
both direct sunlight and reflected light from surrounding
surfaces, generating electricity from both sides of the
panel simultaneously. HIT Double can increase the
amount of electricity produced by up to 30% * compared to
single-sided HIT panels. With high kWh performance, HIT
Double is the perfect choice to maximize rebates for
projects that receive performance based incentives. Enjoy
new possibilities with HIT Double including carports, BIPV,
awnings, fences, trellises, walkways, canopies, deck
coverings and more.
SANYO Energy (USA) Corporation